NI-DAQmx .NET Framework 4.0 API Reference

Content Type
Programming Language
Current manual
Table of Contents
Product DocumentationNI-DAQmx .NET Framework 4.0 API ReferenceAIChannelCollection.CreateCurrentChannel Method (String, String, AITerminalConfiguration, Double, Double, Double, AICurrentUnits)Current page
Table of Contents

AIChannelCollection.CreateCurrentChannel Method (String, String, AITerminalConfiguration, Double, Double, Double, AICurrentUnits)

AIChannelCollection.CreateCurrentChannel Method (String, String, AITerminalConfiguration, Double, Double, Double, AICurrentUnits)

AIChannelCollectionCreateCurrentChannel Method (String, String, AITerminalConfiguration, Double, Double, Double, AICurrentUnits)

Creates an AIChannel with the specified external shunt resistor to measure current. This method adds one or more physical channels to the AIChannelCollection.

Namespace:  NationalInstruments.DAQmx
Assembly:  NationalInstruments.DAQmx (in NationalInstruments.DAQmx.dll) Version: 20.7.40.49302

Syntax

public AIChannel CreateCurrentChannel(
	string physicalChannelName,
	string nameToAssignChannel,
	AITerminalConfiguration terminalConfiguration,
	double minimumValue,
	double maximumValue,
	double externalShuntResistorValue,
	AICurrentUnits units
)
Public Function CreateCurrentChannel ( 
	physicalChannelName As String,
	nameToAssignChannel As String,
	terminalConfiguration As AITerminalConfiguration,
	minimumValue As Double,
	maximumValue As Double,
	externalShuntResistorValue As Double,
	units As AICurrentUnits
) As AIChannel

Parameters

physicalChannelName
Type: SystemString
The names of one or more physical channels to use to create one or more local virtual channels.
nameToAssignChannel
Type: SystemString
One or more names to assign to the created local virtual channels. To use the physical channel name as the local virtual channel name, set this value to Empty.
terminalConfiguration
Type: NationalInstruments.DAQmxAITerminalConfiguration
The input terminal configuration. To use the default terminal configuration for the physical channel(s) being used, pass a value of -1 casted to an AITerminalConfiguration.
minimumValue
Type: SystemDouble
The minimum value expected from the measurement, in units.
maximumValue
Type: SystemDouble
The maximum value expected from the measurement, in units.
externalShuntResistorValue
Type: SystemDouble
The value in ohms of an external shunt resistor.
units
Type: NationalInstruments.DAQmxAICurrentUnits
The units to use to return the measurement.

Return Value

Type: AIChannel
The newly created AIChannel.

Exceptions

ExceptionCondition
DaqExceptionThe NI-DAQmx driver returned an error.

Remarks

This method creates a local virtual channel for every physical channel name you specify. If you create multiple local virtual channels with one call to this method, you can specify a comma-delimited list of names for nameToAssignChannel. If you provide fewer local virtual channel names in nameToAssignChannel than you create, NI-DAQmx automatically assigns names to the local virtual channels.

If you do not provide a value for nameToAssignChannel, NI-DAQmx uses the physicalChannelName as the local virtual channel name. If you use nameToAssignChannel to create a name for the local virtual channel, you must use this name in other properties and methods.

Use this method with devices that do not have a built-in shunt resistor. You must attach an external shunt resistor.

The NI-DAQmx driver does not determine if the requested settings are possible until the task is verified. CreateCurrentChannel(String, String, AITerminalConfiguration, Double, Double, Double, AICurrentUnits) does not throw an exception for parameter values that are not compatible with your hardware or other settings in your task. To determine if all of the settings for a Task are valid, you must verify the task by starting the task, either with Start or by reading from or writing to the task, or by calling Control(TaskAction) with Verify.

See Also

Was this information helpful?