NationalInstruments.RFmx.TdscdmaMX
- Updated2025-01-27
- 5 minute(s) read
NationalInstruments.RFmx.TdscdmaMX
Classes
Name | Description |
---|---|
RFmxTdscdmaMX | Defines a root class which is used to identify and control TDSCDMA signal configuration. |
RFmxTdscdmaMXAcp | Represents the ACP measurement. |
RFmxTdscdmaMXAcpConfiguration | Provides methods to configure the ACP measurement. |
RFmxTdscdmaMXAcpResults | Provides methods to fetch and read the ACP measurement results. |
RFmxTdscdmaMXCda | Represents the CDA measurement. |
RFmxTdscdmaMXCdaConfiguration | Provides methods to configure the CDA measurement. |
RFmxTdscdmaMXCdaResults | Provides methods to fetch and read the CDA measurement results. |
RFmxTdscdmaMXChp | Represents the CHP measurement. |
RFmxTdscdmaMXChpConfiguration | Provides methods to configure the CHP measurement. |
RFmxTdscdmaMXChpResults | Provides methods to fetch and read the CHP measurement results. |
RFmxTdscdmaMXConstants | Specifies constants for I/O terminals. |
RFmxTdscdmaMXModAcc | Represents the ModAcc measurement. |
RFmxTdscdmaMXModAccConfiguration | Provides methods to configure the ModAcc measurement. |
RFmxTdscdmaMXModAccResults | Provides methods to fetch and read the ModAcc measurement results. |
RFmxTdscdmaMXObw | Represents the OBW measurement. |
RFmxTdscdmaMXObwConfiguration | Provides methods to configure the OBW measurement. |
RFmxTdscdmaMXObwResults | Provides methods to fetch and read the OBW measurement results. |
RFmxTdscdmaMXPvt | Represents the PVT measurement. |
RFmxTdscdmaMXPvtConfiguration | Provides methods to configure the PVT measurement. |
RFmxTdscdmaMXPvtResults | Provides methods to fetch and read the PVT measurement results. |
RFmxTdscdmaMXSem | Represents the SEM measurement. |
RFmxTdscdmaMXSemConfiguration | Provides methods to configure the SEM measurement. |
RFmxTdscdmaMXSemResults | Provides methods to fetch and read the SEM measurement results. |
RFmxTdscdmaMXSlotPower | Represents the SlotPower measurement. |
RFmxTdscdmaMXSlotPowerConfiguration | Provides methods to configure the SlotPower measurement. |
RFmxTdscdmaMXSlotPowerResults | Provides methods to fetch and read the SlotPower measurement results. |
RFmxTdscdmaMXSubObject | Represents members that are common to all sub-object of RFmxTdscdmaMX classes. |
Interfaces
None
Structures
None
Enumerations
Name | Description |
---|---|
RFmxTdscdmaMXAcpAveragingEnabled | Specifies whether to enable averaging for the ACP measurement. |
RFmxTdscdmaMXAcpAveragingType | Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for ACP measurement. |
RFmxTdscdmaMXAcpFftOverlapMode | Specifies how overlapping is applied when computing the FFT of the acquired samples. The default value is Disabled. |
RFmxTdscdmaMXAcpIFOutputPowerOffsetAuto | Specifies whether the measurement calculates an IF output power level offset for the offset channels to improve the dynamic range of the ACP measurement. This method is used only if you set the SetMeasurementMethod(string, RFmxTdscdmaMXAcpMeasurementMethod) method to DynamicRange. |
RFmxTdscdmaMXAcpMeasurementMethod | Specifies the method for performing the ACP measurement. |
RFmxTdscdmaMXAcpNoiseCompensationEnabled | Specifies whether to enable compensation of the channel powers for the inherent noise floor of the signal analyzer. Supported Devices: PXIe-5663/5665/5668R, PXIe-5830/5831/5832. |
RFmxTdscdmaMXAcpRbwAutoBandwidth | Specifies whether the measurement calculates the RBW. |
RFmxTdscdmaMXAcpRbwFilterType | Specifies the shape of the digital RBW filter. |
RFmxTdscdmaMXAcpSweepTimeAuto | Specifies whether the measurement calculates the sweep time. |
RFmxTdscdmaMXCdaAveragingEnabled | Specifies whether to enable averaging for the code domain analysis (CDA) measurement. |
RFmxTdscdmaMXCdaIQGainImbalanceRemovalEnabled | Specifies whether to remove the I/Q gain imbalance before the code domain analysis (CDA) measurement. |
RFmxTdscdmaMXCdaIQOffsetRemovalEnabled | Specifies whether to remove the I/Q offset before the code domain analysis (CDA) measurement. |
RFmxTdscdmaMXCdaIQQuadratureErrorRemovalEnabled | Specifies whether to remove the I/Q quadrature error before the code domain analysis (CDA) measurement. |
RFmxTdscdmaMXCdaPowerUnit | Specifies the measurement unit of the code domain power (CDP) results. |
RFmxTdscdmaMXCdaRrcFilterEnabled | Specifies whether to enable the RRC filter. |
RFmxTdscdmaMXCdaSpectrumInverted | Specifies whether the spectrum of the signal is inverted. |
RFmxTdscdmaMXCdaSynchronizationMode | Specifies the synchronization mode for the code domain analysis (CDA) measurement. Currently, only the Slot mode is supported. |
RFmxTdscdmaMXChannelConfigurationMode | Specifies whether to detect the channels automatically or to use a specified channel configuration. |
RFmxTdscdmaMXChannelType | Specifies the channel type of the user-defined channel. This method is used only when you set the SetChannelConfigurationMode(string, RFmxTdscdmaMXChannelConfigurationMode) method to UserDefined. Use "channel(n)" as the selector string to configure or read this method. |
RFmxTdscdmaMXChpAveragingEnabled | Specifies whether to enable averaging for the CHP measurement. |
RFmxTdscdmaMXChpAveragingType | Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the CHP measurement. |
RFmxTdscdmaMXChpRbwAutoBandwidth | Specifies whether the measurement calculates the RBW. |
RFmxTdscdmaMXChpRbwFilterType | Specifies the shape of the digital RBW filter. |
RFmxTdscdmaMXChpSweepTimeAuto | Specifies whether the measurement calculates the sweep time. |
RFmxTdscdmaMXDigitalEdgeTriggerEdge | Specifies the active edge for the trigger. This method is used only when you set the SetTriggerType(string, RFmxTdscdmaMXTriggerType) method to DigitalEdge. |
RFmxTdscdmaMXIQPowerEdgeTriggerLevelType | Specifies the reference for the SetIQPowerEdgeTriggerLevel(string, double) method. This method is used only when you set the SetTriggerType(string, RFmxTdscdmaMXTriggerType) method to IQPowerEdge. |
RFmxTdscdmaMXIQPowerEdgeTriggerSlope | Specifies whether the device asserts the trigger when the signal power is rising or when the signal power is falling. The device asserts the trigger when the signal power exceeds the specified level with the slope you specify. This method is used only when you set the SetTriggerType(string, RFmxTdscdmaMXTriggerType) method to IQPowerEdge. |
RFmxTdscdmaMXLimitedConfigurationChange | Specifies the set of properties that are considered by RFmx in the locked signal configuration state. |
RFmxTdscdmaMXMeasurementTypes | Specifies the type of measurement. |
RFmxTdscdmaMXMidambleAutoDetectionMode | Specifies the midamble auto detection mode. |
RFmxTdscdmaMXModAccAveragingEnabled | Specifies whether to enable averaging for the ModAcc measurement. |
RFmxTdscdmaMXModAccDetectedModulationType | Returns the modulation type of the selected channel within the set of active channels. If the averaging is enabled, this method refers to the last averaging iteration. Use "channel(n)" as the selector string to read this result. |
RFmxTdscdmaMXModAccIQGainImbalanceRemovalEnabled | Specifies whether to remove the I/Q gain imbalance before the ModAcc measurement. |
RFmxTdscdmaMXModAccIQOffsetRemovalEnabled | Specifies whether to remove the I/Q offset before the EVM measurement. |
RFmxTdscdmaMXModAccIQQuadratureErrorRemovalEnabled | Specifies whether to remove the I/Q quadrature error before the ModAcc measurement. |
RFmxTdscdmaMXModAccRrcFilterEnabled | Specifies whether to enable the RRC filter in the ModAcc measurement. Use this method to disable the filter if the received signal is already RRC-filtered. |
RFmxTdscdmaMXModAccSlotType | Specifies the type of the time slot for the ModAcc measurement. |
RFmxTdscdmaMXModAccSpectrumInverted | Specifies whether the spectrum of the signal is inverted. |
RFmxTdscdmaMXModAccSynchronizationMode | Specifies the synchronization mode for the ModAcc measurement. |
RFmxTdscdmaMXModulationType | Specifies the modulation type of the user-defined channel. This method is used only when you set the SetChannelConfigurationMode(string, RFmxTdscdmaMXChannelConfigurationMode) method to UserDefined. Use "channel(n)" as the selector string to configure or read this method. |
RFmxTdscdmaMXObwAveragingEnabled | Specifies whether to enable averaging for the OBW measurement. |
RFmxTdscdmaMXObwAveragingType | Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the OBW measurement. |
RFmxTdscdmaMXObwRbwAutoBandwidth | Specifies whether the measurement calculates the RBW. |
RFmxTdscdmaMXObwRbwFilterType | Specifies the shape of the digital RBW filter. |
RFmxTdscdmaMXObwSweepTimeAuto | Specifies whether the measurement calculates the sweep time. |
RFmxTdscdmaMXPropertyId | Specifies all the attribute identifiers. |
RFmxTdscdmaMXPvtAveragingEnabled | Specifies whether to enable averaging for the power versus time (PVT) measurement. |
RFmxTdscdmaMXPvtAveragingType | Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the power versus time (PVT) measurement. |
RFmxTdscdmaMXPvtMeasurementMethod | Specifies the method for performing the power versus time (PVT) measurement. |
RFmxTdscdmaMXPvtMeasurementStatus | Returns the overall status of the power versus time (PVT) measurement. |
RFmxTdscdmaMXPvtRRCFilterEnabled | Specifies whether to enable the RRC filter. Use this method to disable the filter if the received signal is already RRC-filtered. |
RFmxTdscdmaMXPvtSegmentStatus | Returns the measurement status for an individual power versus time (PVT) measurement segment. |
RFmxTdscdmaMXSemAveragingEnabled | Specifies whether to enable averaging for the SEM measurement. |
RFmxTdscdmaMXSemAveragingType | Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the SEM measurement. |
RFmxTdscdmaMXSemLowerOffsetMeasurementStatus | Indicates the lower offset segment measurement status based on the measurement limits specified by the standard. Use "offset(n)" as the selector string to read this result. |
RFmxTdscdmaMXSemMeasurementStatus | Indicates the overall measurement status based on the measurement limits specified by the standard for each offset segment. |
RFmxTdscdmaMXSemOffsetRbwFilterType | Returns the the type of RBW filter used to sweep the offset segment. |
RFmxTdscdmaMXSemSweepTimeAuto | Specifies whether the measurement calculates the sweep time. |
RFmxTdscdmaMXSemUpperOffsetMeasurementStatus | Indicates the upper offset measurement status based on measurement limits specified by the standard. Use "offset(n)" as the selector string to read this result. |
RFmxTdscdmaMXSlotPowerRrcFilterEnabled | Specifies whether the RRC filter should be enabled or not. |
RFmxTdscdmaMXSlotPowerSpectrumInverted | Specifies whether the spectrum of the signal is inverted. |
RFmxTdscdmaMXTriggerMinimumQuietTimeMode | Specifies whether the measurement calculates the minimum quiet time used for triggering. |
RFmxTdscdmaMXTriggerType | Specifies the trigger type. |
Delegates
None