NationalInstruments.RFmx.TdscdmaMX

Classes

NameDescription
RFmxTdscdmaMX

Defines a root class which is used to identify and control TDSCDMA signal configuration.

RFmxTdscdmaMXAcp

Represents the ACP measurement.

RFmxTdscdmaMXAcpConfiguration

Provides methods to configure the ACP measurement.

RFmxTdscdmaMXAcpResults

Provides methods to fetch and read the ACP measurement results.

RFmxTdscdmaMXCda

Represents the CDA measurement.

RFmxTdscdmaMXCdaConfiguration

Provides methods to configure the CDA measurement.

RFmxTdscdmaMXCdaResults

Provides methods to fetch and read the CDA measurement results.

RFmxTdscdmaMXChp

Represents the CHP measurement.

RFmxTdscdmaMXChpConfiguration

Provides methods to configure the CHP measurement.

RFmxTdscdmaMXChpResults

Provides methods to fetch and read the CHP measurement results.

RFmxTdscdmaMXConstants

Specifies constants for I/O terminals.

RFmxTdscdmaMXModAcc

Represents the ModAcc measurement.

RFmxTdscdmaMXModAccConfiguration

Provides methods to configure the ModAcc measurement.

RFmxTdscdmaMXModAccResults

Provides methods to fetch and read the ModAcc measurement results.

RFmxTdscdmaMXObw

Represents the OBW measurement.

RFmxTdscdmaMXObwConfiguration

Provides methods to configure the OBW measurement.

RFmxTdscdmaMXObwResults

Provides methods to fetch and read the OBW measurement results.

RFmxTdscdmaMXPvt

Represents the PVT measurement.

RFmxTdscdmaMXPvtConfiguration

Provides methods to configure the PVT measurement.

RFmxTdscdmaMXPvtResults

Provides methods to fetch and read the PVT measurement results.

RFmxTdscdmaMXSem

Represents the SEM measurement.

RFmxTdscdmaMXSemConfiguration

Provides methods to configure the SEM measurement.

RFmxTdscdmaMXSemResults

Provides methods to fetch and read the SEM measurement results.

RFmxTdscdmaMXSlotPower

Represents the SlotPower measurement.

RFmxTdscdmaMXSlotPowerConfiguration

Provides methods to configure the SlotPower measurement.

RFmxTdscdmaMXSlotPowerResults

Provides methods to fetch and read the SlotPower measurement results.

RFmxTdscdmaMXSubObject

Represents members that are common to all sub-object of RFmxTdscdmaMX classes.

Interfaces

None

Structures

None

Enumerations

NameDescription
RFmxTdscdmaMXAcpAveragingEnabled

Specifies whether to enable averaging for the ACP measurement.

RFmxTdscdmaMXAcpAveragingType

Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for ACP measurement.

RFmxTdscdmaMXAcpFftOverlapMode

Specifies how overlapping is applied when computing the FFT of the acquired samples. The default value is Disabled.

RFmxTdscdmaMXAcpIFOutputPowerOffsetAuto

Specifies whether the measurement calculates an IF output power level offset for the offset channels to improve the dynamic range of the ACP measurement. This method is used only if you set the SetMeasurementMethod(string, RFmxTdscdmaMXAcpMeasurementMethod) method to DynamicRange.

RFmxTdscdmaMXAcpMeasurementMethod

Specifies the method for performing the ACP measurement.

RFmxTdscdmaMXAcpNoiseCompensationEnabled

Specifies whether to enable compensation of the channel powers for the inherent noise floor of the signal analyzer. Supported Devices: PXIe-5663/5665/5668R, PXIe-5830/5831/5832.

RFmxTdscdmaMXAcpRbwAutoBandwidth

Specifies whether the measurement calculates the RBW.

RFmxTdscdmaMXAcpRbwFilterType

Specifies the shape of the digital RBW filter.

RFmxTdscdmaMXAcpSweepTimeAuto

Specifies whether the measurement calculates the sweep time.

RFmxTdscdmaMXCdaAveragingEnabled

Specifies whether to enable averaging for the code domain analysis (CDA) measurement.

RFmxTdscdmaMXCdaIQGainImbalanceRemovalEnabled

Specifies whether to remove the I/Q gain imbalance before the code domain analysis (CDA) measurement.

RFmxTdscdmaMXCdaIQOffsetRemovalEnabled

Specifies whether to remove the I/Q offset before the code domain analysis (CDA) measurement.

RFmxTdscdmaMXCdaIQQuadratureErrorRemovalEnabled

Specifies whether to remove the I/Q quadrature error before the code domain analysis (CDA) measurement.

RFmxTdscdmaMXCdaPowerUnit

Specifies the measurement unit of the code domain power (CDP) results.

RFmxTdscdmaMXCdaRrcFilterEnabled

Specifies whether to enable the RRC filter.

RFmxTdscdmaMXCdaSpectrumInverted

Specifies whether the spectrum of the signal is inverted.

RFmxTdscdmaMXCdaSynchronizationMode

Specifies the synchronization mode for the code domain analysis (CDA) measurement. Currently, only the Slot mode is supported.

RFmxTdscdmaMXChannelConfigurationMode

Specifies whether to detect the channels automatically or to use a specified channel configuration.

RFmxTdscdmaMXChannelType

Specifies the channel type of the user-defined channel. This method is used only when you set the SetChannelConfigurationMode(string, RFmxTdscdmaMXChannelConfigurationMode) method to UserDefined. Use "channel(n)" as the selector string to configure or read this method.

RFmxTdscdmaMXChpAveragingEnabled

Specifies whether to enable averaging for the CHP measurement.

RFmxTdscdmaMXChpAveragingType

Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the CHP measurement.

RFmxTdscdmaMXChpRbwAutoBandwidth

Specifies whether the measurement calculates the RBW.

RFmxTdscdmaMXChpRbwFilterType

Specifies the shape of the digital RBW filter.

RFmxTdscdmaMXChpSweepTimeAuto

Specifies whether the measurement calculates the sweep time.

RFmxTdscdmaMXDigitalEdgeTriggerEdge

Specifies the active edge for the trigger. This method is used only when you set the SetTriggerType(string, RFmxTdscdmaMXTriggerType) method to DigitalEdge.

RFmxTdscdmaMXIQPowerEdgeTriggerLevelType

Specifies the reference for the SetIQPowerEdgeTriggerLevel(string, double) method. This method is used only when you set the SetTriggerType(string, RFmxTdscdmaMXTriggerType) method to IQPowerEdge.

RFmxTdscdmaMXIQPowerEdgeTriggerSlope

Specifies whether the device asserts the trigger when the signal power is rising or when the signal power is falling. The device asserts the trigger when the signal power exceeds the specified level with the slope you specify. This method is used only when you set the SetTriggerType(string, RFmxTdscdmaMXTriggerType) method to IQPowerEdge.

RFmxTdscdmaMXLimitedConfigurationChange

Specifies the set of properties that are considered by RFmx in the locked signal configuration state.

RFmxTdscdmaMXMeasurementTypes

Specifies the type of measurement.

RFmxTdscdmaMXMidambleAutoDetectionMode

Specifies the midamble auto detection mode.

RFmxTdscdmaMXModAccAveragingEnabled

Specifies whether to enable averaging for the ModAcc measurement.

RFmxTdscdmaMXModAccDetectedModulationType

Returns the modulation type of the selected channel within the set of active channels. If the averaging is enabled, this method refers to the last averaging iteration. Use "channel(n)" as the selector string to read this result.

RFmxTdscdmaMXModAccIQGainImbalanceRemovalEnabled

Specifies whether to remove the I/Q gain imbalance before the ModAcc measurement.

RFmxTdscdmaMXModAccIQOffsetRemovalEnabled

Specifies whether to remove the I/Q offset before the EVM measurement.

RFmxTdscdmaMXModAccIQQuadratureErrorRemovalEnabled

Specifies whether to remove the I/Q quadrature error before the ModAcc measurement.

RFmxTdscdmaMXModAccRrcFilterEnabled

Specifies whether to enable the RRC filter in the ModAcc measurement. Use this method to disable the filter if the received signal is already RRC-filtered.

RFmxTdscdmaMXModAccSlotType

Specifies the type of the time slot for the ModAcc measurement.

RFmxTdscdmaMXModAccSpectrumInverted

Specifies whether the spectrum of the signal is inverted.

RFmxTdscdmaMXModAccSynchronizationMode

Specifies the synchronization mode for the ModAcc measurement.

RFmxTdscdmaMXModulationType

Specifies the modulation type of the user-defined channel. This method is used only when you set the SetChannelConfigurationMode(string, RFmxTdscdmaMXChannelConfigurationMode) method to UserDefined. Use "channel(n)" as the selector string to configure or read this method.

RFmxTdscdmaMXObwAveragingEnabled

Specifies whether to enable averaging for the OBW measurement.

RFmxTdscdmaMXObwAveragingType

Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the OBW measurement.

RFmxTdscdmaMXObwRbwAutoBandwidth

Specifies whether the measurement calculates the RBW.

RFmxTdscdmaMXObwRbwFilterType

Specifies the shape of the digital RBW filter.

RFmxTdscdmaMXObwSweepTimeAuto

Specifies whether the measurement calculates the sweep time.

RFmxTdscdmaMXPropertyId

Specifies all the attribute identifiers.

RFmxTdscdmaMXPvtAveragingEnabled

Specifies whether to enable averaging for the power versus time (PVT) measurement.

RFmxTdscdmaMXPvtAveragingType

Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the power versus time (PVT) measurement.

RFmxTdscdmaMXPvtMeasurementMethod

Specifies the method for performing the power versus time (PVT) measurement.

RFmxTdscdmaMXPvtMeasurementStatus

Returns the overall status of the power versus time (PVT) measurement.

RFmxTdscdmaMXPvtRRCFilterEnabled

Specifies whether to enable the RRC filter. Use this method to disable the filter if the received signal is already RRC-filtered.

RFmxTdscdmaMXPvtSegmentStatus

Returns the measurement status for an individual power versus time (PVT) measurement segment.

RFmxTdscdmaMXSemAveragingEnabled

Specifies whether to enable averaging for the SEM measurement.

RFmxTdscdmaMXSemAveragingType

Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the SEM measurement.

RFmxTdscdmaMXSemLowerOffsetMeasurementStatus

Indicates the lower offset segment measurement status based on the measurement limits specified by the standard. Use "offset(n)" as the selector string to read this result.

RFmxTdscdmaMXSemMeasurementStatus

Indicates the overall measurement status based on the measurement limits specified by the standard for each offset segment.

RFmxTdscdmaMXSemOffsetRbwFilterType

Returns the the type of RBW filter used to sweep the offset segment.

RFmxTdscdmaMXSemSweepTimeAuto

Specifies whether the measurement calculates the sweep time.

RFmxTdscdmaMXSemUpperOffsetMeasurementStatus

Indicates the upper offset measurement status based on measurement limits specified by the standard. Use "offset(n)" as the selector string to read this result.

RFmxTdscdmaMXSlotPowerRrcFilterEnabled

Specifies whether the RRC filter should be enabled or not.

RFmxTdscdmaMXSlotPowerSpectrumInverted

Specifies whether the spectrum of the signal is inverted.

RFmxTdscdmaMXTriggerMinimumQuietTimeMode

Specifies whether the measurement calculates the minimum quiet time used for triggering.

RFmxTdscdmaMXTriggerType

Specifies the trigger type.

Delegates

None