NI 9326 Supported Properties

NI 9326 Supported Properties

DAQmx Buffer Properties

Input >> Buffer Size

Input >> Onboard Buffer Size

Output >> Buffer Size

DAQmx Channel Properties

Counter Input >> Maximum Value

Counter Input >> Minimum Value

Counter Input >> Custom Scale Name

Counter Input >> Measurement Type

Counter Input >> Frequency >> Units

Counter Input >> Frequency >> Input >> Terminal

Counter Input >> Frequency >> Input >> Terminal Configuration

Counter Input >> Frequency >> Input >> Logic Level Behavior

Counter Input >> Frequency >> Input >> Threshold Level

Counter Input >> Frequency >> Input >> Hysteresis

Counter Input >> Frequency >> Input >> Digital Filter >> Enable

Counter Input >> Frequency >> Input >> Digital Filter >> Minimum Pulse Width

Counter Input >> Frequency >> Starting Edge

Counter Input >> Frequency >> Measurement Specifications >> Method

Counter Input >> Frequency >> Measurement Specifications >> High Frequency >> Measurement Time

Counter Input >> Frequency >> Measurement Specifications >> Large Range >> Divisor

Counter Input >> Period >> Units

Counter Input >> Period >> Input >> Terminal

Counter Input >> Period >> Input >> Terminal Configuration

Counter Input >> Period >> Input >> Logic Level Behavior

Counter Input >> Period >> Input >> Threshold Level

Counter Input >> Period >> Input >> Hysteresis

Counter Input >> Period >> Input >> Digital Filter >> Enable

Counter Input >> Period >> Input >> Digital Filter >> Minimum Pulse Width

Counter Input >> Period >> Starting Edge

Counter Input >> Period >> Measurement Specifications >> Method

Counter Input >> Period >> Measurement Specifications >> High Frequency >> Measurement Time

Counter Input >> Period >> Measurement Specifications >> Large Range >> Divisor

Counter Input >> Count Edges >> Input >> Terminal

Counter Input >> Count Edges >> Input >> Terminal Configuration

Counter Input >> Count Edges >> Input >> Logic Level Behavior

Counter Input >> Count Edges >> Input >> Threshold Level

Counter Input >> Count Edges >> Input >> Hysteresis

Counter Input >> Count Edges >> Input >> Digital Filter >> Enable

Counter Input >> Count Edges >> Input >> Digital Filter >> Minimum Pulse Width

Counter Input >> Count Edges >> Input >> Digital Synchronization >> Enable

Counter Input >> Count Edges >> Count Direction >> Direction

Counter Input >> Count Edges >> Count Direction >> Input >> Terminal

Counter Input >> Count Edges >> Count Direction >> Input >> Terminal Configuration

Counter Input >> Count Edges >> Count Direction >> Input >> Logic Level Behavior

Counter Input >> Count Edges >> Count Direction >> Input >> Threshold Level

Counter Input >> Count Edges >> Count Direction >> Input >> Hysteresis

Counter Input >> Count Edges >> Count Direction >> Input >> Digital Filter >> Enable

Counter Input >> Count Edges >> Count Direction >> Input >> Digital Filter >> Minimum Pulse Width

Counter Input >> Count Edges >> Initial Count

Counter Input >> Count Edges >> Active Edge

Counter Input >> Count Edges >> Count Reset >> Enable

Counter Input >> Count Edges >> Count Reset >> Reset Count

Counter Input >> Count Edges >> Count Reset >> Input >> Terminal

Counter Input >> Count Edges >> Count Reset >> Input >> Terminal Configuration

Counter Input >> Count Edges >> Count Reset >> Input >> Logic Level Behavior

Counter Input >> Count Edges >> Count Reset >> Input >> Threshold Level

Counter Input >> Count Edges >> Count Reset >> Input >> Hysteresis

Counter Input >> Count Edges >> Count Reset >> Input >> Digital Filter >> Enable

Counter Input >> Count Edges >> Count Reset >> Input >> Digital Filter >> Minimum Pulse Width

Counter Input >> Count Edges >> Count Reset >> Active Edge

Counter Input >> Count Edges >> Gate >> Enable

Counter Input >> Count Edges >> Gate >> Input >> Terminal

Counter Input >> Count Edges >> Gate >> Input >> Terminal Configuration

Counter Input >> Count Edges >> Gate >> Input >> Logic Level Behavior

Counter Input >> Count Edges >> Gate >> Input >> Threshold Level

Counter Input >> Count Edges >> Gate >> Input >> Hysteresis

Counter Input >> Count Edges >> Gate >> Input >> Digital Filter >> Enable

Counter Input >> Count Edges >> Gate >> Input >> Digital Filter >> Minimum Pulse Width

Counter Input >> Count Edges >> Gate >> Pause When

Counter Input >> General Properties >> Input Configuration >> Voltage Threshold Level

Counter Input >> General Properties >> Filter >> Enable

Counter Input >> General Properties >> Filter >> Frequency

Counter Input >> General Properties >> Filter >> Response

Counter Input >> General Properties >> Filter >> Order

Counter Input >> General Properties >> Filter >> Filter Delay

Counter Input >> General Properties >> Filter >> Filter Delay Units

Counter Input >> General Properties >> More >> Sample Clock Overrun Behavior

Counter Input >> General Properties >> More >> Sample Clock Overrun Sentinel Value

Counter Input >> General Properties >> More >> Advanced >> Data Transfer and Memory >> Data Transfer Mechanism

Counter Input >> General Properties >> More >> Advanced >> Data Transfer and Memory >> Data Transfer Request Condition

Counter Input >> General Properties >> More >> Advanced >> Data Transfer and Memory >> USB Transfer Request Size

Counter Input >> General Properties >> More >> Advanced >> Data Transfer and Memory >> Memory Mapping for Programmed IO Enable

Counter Input >> General Properties >> More >> Advanced >> Maximum Measurable Period

General Properties >> Channel Type

General Properties >> Physical Channel Name

General Properties >> Description

General Properties >> Is Global

DAQmx Device Properties

Device Is Simulated

Identification >> Product Category

Identification >> Product Type

Identification >> Product Number

Identification >> Device Serial Number

Identification >> Accessory >> Product Types

Identification >> Accessory >> Product Numbers

Identification >> Accessory >> Serial Numbers

Identification >> Carrier Serial Number

Identification >> FieldDAQ >> Device Name

Identification >> FieldDAQ >> Bank Device Names

Chassis >> Module Device Names

Triggering >> Analog Triggering Supported

Triggering >> Digital Triggering Supported

Triggering >> Time Triggering Supported

I/O Type >> Analog Input >> Physical Channels

I/O Type >> Analog Input >> Measurement Types

I/O Type >> Analog Output >> Physical Channels

I/O Type >> Analog Output >> Output Types

I/O Type >> Digital Input >> Lines

I/O Type >> Digital Input >> Ports

I/O Type >> Digital Output >> Lines

I/O Type >> Digital Output >> Ports

I/O Type >> Counter Input >> Physical Channels

I/O Type >> Counter Input >> Measurement Types

I/O Type >> Counter Input >> Timing >> Sample Clock Supported

I/O Type >> Counter Input >> Timing >> Sample Modes

I/O Type >> Counter Output >> Physical Channels

I/O Type >> Counter Output >> Output Types

TEDS >> Hardware TEDS Supported

Bus >> Number of DMA Channels

Location >> Bus Type

Location >> PCI >> Bus Number

Location >> PCI >> Device Number

Location >> PXI >> Chassis Number

Location >> PXI >> Slot Number

Location >> CompactDAQ >> Chassis Device Name

Location >> CompactDAQ >> Slot Number

Location >> CompactRIO >> Chassis Device Name

Location >> CompactRIO >> Slot Number

Location >> TCP/IP >> Hostname

Location >> TCP/IP >> Ethernet IP Address

Location >> TCP/IP >> Wireless IP Address

Terminals

DAQmx Read Properties

RelativeTo

Offset

Channels to Read

Read All Available Samples

Auto Start

OverWrite Mode

Logging >> File Path

Logging >> Mode

Logging >> TDMS >> Group Name

Logging >> TDMS >> Operation

Logging >> Pause

Logging >> Samples Per File

Logging >> File Write Size

Logging >> File Pre-allocation Size

Status >> Current Read Position

Status >> Available Samples Per Channel

Status >> Total Samples Per Channel Acquired

Advanced >> Raw Data Width

Advanced >> Number of Channels

Advanced >> Digital Input >> Number of Booleans Per Channel

Advanced >> Wait Mode

Advanced >> Sleep Time

DAQmx Timing Properties

Sample Quantity >> Sample Mode

Sample Quantity >> Samples Per Channel

Sample Timing Type

Sample Clock >> Rate

Sample Clock >> Source

Sample Clock >> Active Edge

Sample Clock >> Underflow Behavior

Sample Clock >> Terminal

Sample Clock >> Digital Filter >> Enable

Sample Clock >> Digital Filter >> Minimum Pulse Width

Sample Clock >> Digital Filter >> Timebase >> Source

Sample Clock >> Digital Filter >> Timebase >> Rate

Sample Clock >> Write Waveform >> Use Initial Waveform dt

DAQmx Trigger Properties

Start >> Trigger Type

Start >> Terminal

Start >> Digital Edge >> Source

Start >> Digital Edge >> Edge

Start >> Digital Edge >> Digital Filter >> Enable

Start >> Digital Edge >> Digital Filter >> Minimum Pulse Width

Start >> Digital Edge >> Digital Filter >> Timebase >> Source

Start >> Digital Edge >> Digital Filter >> Timebase >> Rate

Start >> More >> Retriggerable

More >> Pause >> Trigger Type

More >> Pause >> Terminal

More >> Pause >> Digital Level >> Source

More >> Pause >> Digital Level >> Pause When

More >> Pause >> Digital Level >> Digital Filter >> Enable

More >> Pause >> Digital Level >> Digital Filter >> Minimum Pulse Width

More >> Pause >> Digital Level >> Digital Filter >> Timebase >> Source

More >> Pause >> Digital Level >> Digital Filter >> Timebase >> Rate

More >> Arm Start >> Trigger Type

More >> Arm Start >> Terminal

More >> Arm Start >> Digital Edge >> Source

More >> Arm Start >> Digital Edge >> Edge

More >> Arm Start >> Digital Edge >> Digital Filter >> Enable

More >> Arm Start >> Digital Edge >> Digital Filter >> Minimum Pulse Width

More >> Arm Start >> Digital Edge >> Digital Filter >> Timebase >> Source

More >> Arm Start >> Digital Edge >> Digital Filter >> Timebase >> Rate

Was this information helpful?