Counter Input >> Period >> Input >> Threshold Level
- Updated2023-03-16
- 1 minute(s) read
Data Type: | float64 |
Description: | Specifies the voltage level at which to recognize waveform repetitions. Select a voltage level that occurs only once within the entire period of a waveform. You also can select a voltage that occurs only once while the voltage rises or falls. |
You can get/set/reset this property using:
DAQmxGetCIPeriodThreshVoltage
DAQmxSetCIPeriodThreshVoltage
DAQmxResetCIPeriodThreshVoltage