NI Hardware Support
- Updated2025-01-28
- 2 minute(s) read
NI Hardware Support
VeriStand supports NI-XNET devices, NI-DAQ devices, and NI FPGA targets.
For the best performance, use NI-DAQ devices that support hardware-timed single point (HWTSP) I/O or on-demand sampling. Refer to DAQ Devices with Hardware-Timed Single Point Sampling Mode Support for a list of NI-DAQ devices that support HWTSP I/O. Refer to the custom device’s GitHub repository for a list of supported modules.
Hardware Feature | NI-XNET Devices | NI-DAQ Devices | NI FPGA Targets |
---|---|---|---|
Custom FPGA VIs | No | No | Yes1 |
Hardware timing | No | Yes | Yes |
Analog I/O | No | Yes | Yes |
Digital I/O | No | Yes | Yes |
Pulse Width Modulation (PWM) I/O | No | Yes2 | Yes |
Auto-discovery of installed devices and I/O modules | Yes | Yes | Yes |
1 Refer to the FPGA Targets with Built-in Support section for a list of NI FPGA targets for which VeriStand provides bitfiles and FPGA configuration files.
2 Device support for PWM I/O includes:
|
Supported
Targets
- PXI/PCI—Any PXI controller with at least 256 MB of RAM.
- CompactRIO/Single-Board RIO—Any CompactRIO or Single-Board RIO device with at least 128 MB of
RAM. Note The cRIO-906x series meets this requirement, but because it is an ARM-based controller, it is not supported in VeriStand 2021 or later.
- Desktop PC—Any PC running Windows 7, Vista, XP Service Pack 3 or later, Server 2003 R2 (32-bit), or Server 2008 R2 (64-bit).
FPGA
Targets with Built-in Support
- NI cRIO-9103 Note The files provided for the NI cRIO-9103 are configured for the NI 9215, NI 9263, NI 9411, and NI 9474 I/O modules.
- NI PXI/PCI-7811R
- NI PXI/PCI-7813R
- NI PXI/PCI-7831R
- NI PXI/PCI-7833R
- NI PXI/PCIe-7841R
- NI PXI/PCIe-7842R
- NI PXI/PCIe-7851R
- NI PXI/PCIe-7852R
- NI PXI-7853R
- NI PXI-7854R
All bitfiles use direct memory access (DMA) to transfer data.
You can use the LabVIEW FPGA Module to create custom FPGA bitfiles for these or other FPGA targets.
Supported SCXI Modules
- SCXI-1100
- SCXI-1102
- SCXI-1102B
- SCXI-1102C
- SCXI-1104
- SCXI-1104C
- SCXI-1112
- SCXI-1120
- SCXI-1120D
- SCXI-1121
- SCXI-1122
- SCXI-1124
- SCXI-1125
- SCXI-1126
- SCXI-1127
- SCXI-1128
- SCXI-1140
- SCXI-1141
- SCXI-1142
- SCXI-1143
- SCXI-1160
- SCXI-1161
- SCXI-1162
- SCXI-1162HV
- SCXI-1163
- SCXI-1163R
- SCXI-1190
- SCXI-1191
- SCXI-1192
- SCXI-1520
- SCXI-1530
- SCXI-1531
- SCXI-1540
- SCXI-1581
Related Information
- DAQ Devices with Hardware-Timed Single Point Sampling Mode Support
- Scan Engine and EtherCAT custom device GitHub repository
- Adding and Configuring a Hardware Device
Add and configure NI hardware, timing and sync devices, and custom devices.
- Creating a Custom FPGA Bitfile