Configuring the Watchdog Timer when Deploying to a Real-Time Target
- Updated2025-04-08
- 1 minute(s) read
Configuring the Watchdog Timer when Deploying to a Real-Time Target
You can modify the timing watchdog that stops the execution of the VeriStand Engine if too much time elapses when you deploy a project to a real-time target.
The Watchdog Timer Loop executes and resets the Watchdog Timer system channel every 500 milliseconds. When the Primary Control Loop executes, it evaluates whether the Watchdog Timer system channel reports a time greater than 1 second. If it does, VeriStand throws an error and stops execution of the VeriStand Engine.
To enable or disable watchdog functionality, complete the following steps:
- Open System Explorer.
- Select Controller from the configuration tree to display the Controller Configuration page.
- Select .