History Event Delete VI
- Updated2023-02-21
- 3 minute(s) read
History Event Delete VI
Owning Palette: Historical Access VIs
Requires: OPC UA Toolkit
Deletes a history event.
![]() |
OPC UA server refnum in specifies the reference data value of the OPC UA server. | ||||||||||||
![]() |
notifier node ID specifies the ID of the notifier. A notifier is an object that you can subscribe to get events from the associated condition nodes. The format of the node ID is ns=<namespace index>;<identifier type>=<identifier>. A node ID contains the following components:
The format of the node ID can also be ns=<namespace index>;<identifier type>=<identifier>@<index>:<index>. For example, ns=2;s=Folder.Array@1:2. This format only applies to the array data type and allows you to read a single element or a range of elements of an array. You cannot use @ in a node name. For backwards compatibility, notifier node ID also accepts node paths as input for OPC UA servers only. You can regard the node path as the string type identifier of the node ID. For example, a node path can be Device.folder.item. |
||||||||||||
![]() |
event IDs specifies the event IDs to delete. | ||||||||||||
![]() |
error in describes error conditions that occur before this node runs. This input provides standard error in functionality. | ||||||||||||
![]() |
OPC UA server refnum out returns the reference data value of the OPC UA server. | ||||||||||||
![]() |
operation status returns the status of the operation. | ||||||||||||
![]() |
status returns the status code. | ||||||||||||
![]() |
error out contains error information. This output provides standard error out functionality. |
Example
Refer to the OPC UA Demo.lvproj in the labview\examples\Data Communication\OPCUA directory for an example of using the History Event Delete VI.