This document contains known issues for the DAQExpress 2.0.0 Application Software. Not every issue known to NI will appear on this list; it is intended to only show the severe and more common issues that can be encountered.
Each Issue appears as a row in the table and includes these fields:
There are two versions of the known issues list available:
DAQExpress Known Issues by Category
DAQExpress Known Issues by Date
Please refer to Developer Zone Article "LabVIEW Known Issues Categories Defined" for an explanation of the categories and what types of issues are in each category.
You can contact us by phone, email, or the discussion forums. If you are contacting NI in regards to a specific issue, be sure to reference the ID number given in this document. If you have feedback on this specific document, please contact NI on this NI Developer Zone post.
The following items are known issues in DAQExpress 2.0.0 sorted by Category.
| ID | Known Issue | |||||
|---|---|---|---|---|---|---|
| Controls and Indicators | ||||||
| 482816 Return | Selection in Array of Clusters of Arrays constant loses focus. Selecting an array inside a cluster inside another array loses focus when hovering over another element of the top array. This makes it difficult to edit the items in the inner-most array. Workaround: N/A
| |||||
| 620589 Return | Timestamp control doesn't apply changes to the year value if you don't also choose a month. When setting the value for a timestamp control, you can specify the month and year. Changing the year will not take effect unless the month is also changed. Workaround: Always choose a month when setting the date of a Timestamp control.
| |||||
| Menus | ||||||
| 644397 Return | Workbooks do not restore maximized after minimizing the environment window with a maximized workbook open. A maximized workbook window will minimize when the environment window is minimized. Restoring the environment window will also restore the workbook window but not in the maximized view. Workaround: Maximize the workbook window manually after restoring the environment window.
| |||||
| Miscellaneous | ||||||
| 584767 Return | Some UI elements in the environment may not display correctly using custom DPI settings. Some UI elements may display incompletely if using a custom Windows DPI setting of 125%, or similar. Workaround: Use default DPI settings.
| |||||
| 596295 Return | Measurement Panel created for an array of task constants does not propagate name. When a Measurement Panel is created from an empty task constant inside of an array, a new task will be generated for it and a name will be assigned. However, this name will not be automatically updated on the original task constant inside the array. Workaround: Manually rename the task constant.
| |||||
| 630429 Return | While loop's floating comment for "loop iteration" and "stop" are not localized. N/A Workaround: Move cursor on top of Iteration and Condition terminals
| |||||
| 660805 Return | Windows "line per notch" scroll wheel settings do not apply. The scroll wheel movement amount does correlate to the scroll size defined in the Windows mouse settings. For example there's no difference in the amount of block diagram scrolled whether the set to 1 line per notch or 10 lines per notch. Workaround: N/A
| |||||
| 662414 Return | Error & Warnings Panel continuously expands and collapses after repeated pinning and unpinning. Normally, The Error & Warnings panel pops up when the mouse is hovered over it. In some cases, the Errors and Warnings window may expand and collapsed continuously after pinning and unpinning the Errors and Warnings panel. Workaround: Click the tab.
| |||||
Document last updated on 1/5/2018