NI 4070

The NI 4070 is a 6½ digit DMM for the PXI and PCI buses. The NI 4070 can acquire waveforms at 1.8 MS/s. For more information about the NI 4070 specifications, refer to Related Documentation for the NI 4070 specifications document.

Interconnects and Cables

The front of the NI 4070 module has five connectors—four banana plug connectors and one 9-pin mini–circular DIN connector. The four banana plug connectors are high-voltage, safety-agency approved signal connectors. The 9-pin DIN connector labeled AUX I/O is a digital signal connector, which carries triggers and SCXI communication signals. For an illustration of the front panel connectors and wiring instructions, refer to NI 4070 Front Panel Connections.

The input connectors on the NI 4070 are gold-plated, low-thermal copper for best low-voltage performance. The insulator material is a Lexan compound, optimized for low leakage over the full environmental operating range.

For use with the NI 4070, NI recommends selecting a cable with characteristics similar to the Belden 83317E; refer to the Belden CDT Incorporated Web site at www.belden.com for information about this cable.

Tape-wrapped polytetrafluoroethylene (PTFE) insulation guarantees low leakage. Copper conductors with silver plating perform very well for low-voltage measurements because of their low thermal characteristics. Use a cable with at least 90% shielding effectiveness.

Table 11. Belden #83317E Teflon Insulated Cable
Type of Insulator AWG Conductor Material Resistance per Foot Capacitance per Foot
TFE 26 Silver-plated copper, stranded 39 mΩ 35.5 pF

Operation

The NI 4070 can operate as a DMM and can acquire waveforms up to 1.8 MS/s. The following table lists the functions and ranges supported by the NI 4070 while in DMM mode:

DMM Function Ranges
DC Voltage 100 mV, 1 V, 10 V, 100 V, 300 V
AC Voltage 50 mV, 500 mV, 5 V, 50 V, 300 V
DC Current1 20 mA, 200 mA, 1 A
AC Current1 10 mA, 100 mA, 1 A
2-Wire Resistance 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ
4-Wire Resistance 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ, 1 MΩ, 10 MΩ
Diode 10 V at 1 µA / 10µA / 100µA; 4.5 V at 1 mA
Frequency/Period2 1 Hz - 500 kHz / 2 µs - 1 s

1To measure current outside of the normal range on the NI 4070, you must use a current shunt module (CSM). Refer to Measuring Current for more information. 2Frequency/Period voltage ranges are the same as AC voltage ranges.

The following table lists the functions and ranges supported for waveform acquisitions:

Waveform Function Ranges Coupling
Voltage Waveform 100 mV, 1 V, 10 V, 100 V, 300 V AC or DC
Current Waveform1 20 mA, 200 mA, 1 A DC
1To measure current outside of the normal range on the NI 4070, you must use a current shunt module (CSM). Refer to Measuring Current for more information.

The following table lists the available NI 4070 input resistance selections. NI calibrates the NI 4070 for full accuracy with all input resistances shown.

DCV ACV Waveform Acquisitions
Range Input Resistance Range Input Resistance Range Input Resistance
100 mV 10 MΩ (default) or 10 GΩ 50 mV 1 MΩ 100 mV 10 GΩ or 1 MΩ (default)
1 V 10 MΩ (default) or 10 GΩ 500 mV 1 MΩ 1 V 10 GΩ or 1 MΩ (default)
10 V 10 MΩ (default) or 10 GΩ 5 V 1 MΩ 10 V 10 GΩ or 1 MΩ (default)
100 V 10 MΩ (default) 50 V 1 MΩ 100 V 1 MΩ (default)
300 V 10 MΩ (default) 300 V 1 MΩ 300 V 1 MΩ (default)

Additional Features

  • Self-Calibration
  • Auto Zero
  • Configuring Auto Range
  • Offset Compensated Ohms
  • ADC Calibration
  • Input Resistance
  • Configuring Measurement Timing
  • Aperture Time
  • DC Noise Rejection
  • Waveform Acquisitions
  • Single Point Acquisitions
  • Generating Measurement Complete
  • Scanning Switch Modules

Replacing the Fuse

The NI 4070 is equipped with a Fast–Acting fuse designed to help protect the DMM and your test system. For instructions on replacing the fuse, refer to Fuse Replacement.

Calibrating the NI 4070

Calibration maximizes the accuracy of a DMM. To ensure accuracy, you must perform calibration. NI recommends that you externally calibrate every two years. Refer to self-calibration or ADC calibration to internally calibrate the NI 4070. Refer to the NI 4070/4072 6½ Digit FlexDMM Calibration Procedure at the NI Calibration Solutions Web site for information on externally calibrating the NI PXI/PCI-4070/4072. For information on calibrating the NI 4070 using Calibration Executive, refer to the NI Calibration Solutions Web site. All NI measurement devices receive NIST-traceable calibration before shipping.