Use this guide to match your NI Analog Output (AO) 67xx Models PCMCIA, PCI, PXI, or PXI Express (PXIe) DAQ device with a compatible cable and accessory to meet the needs of your application, replacing or expanding your current configuration, or verifying that existing parts can be used in a different configuration.
NI Analog Output 67xx Models (formerly referred to as NI AO Series) are the current generation of NI Analog Output DAQ hardware. They allow for analog output, and digital and counter input and output through a variety of connectivity options.
It is important to work through this guide sequentially to identify and then pair up your device with compatible cables and accessories. To do this, complete the following steps:
Note: Using the page search functionality in your browser to locate your model may speed up this process, typically CTRL+F on Windows or ⌘+F on OS X.
Begin by using the following tables to locate your device or module. Once found, note your connector type, pin count, and any other notes for reference. Next, move to the Cable and Accessory Compatibility Tables.
Important Note: "Group" used in this context is solely to categorize devices together that use the same cables and accessories. It does not necessarily indicate similar functionality, specifications, or other commonalities between the devices.
Model | Connector Type | Notes |
---|---|---|
DAQCard-6715 | VHDCI | PCMCIA interface. Refer to the Known Limitations and Issues List |
PCI-6722 | VHDCI | Refer to the Known Limitations and Issues List |
PXI-6722 | VHDCI | Refer to the Known Limitations and Issues List |
PCI-6723 | VHDCI | Dual Connector. Refer to the Known Limitations and Issues List |
PXI-6723 | VHDCI | Dual Connector. Refer to the Known Limitations and Issues List |
PCIe-6738 | VHDCI | Refer to the Known Limitations and Issues List |
PXIe-6738 | VHDCI | Refer to the Known Limitations and Issues List |
PXIe-6379 | VHDCI | Dual Connector. Refer to the Known Limitations and Issues List |
Model | Connector Type | Notes |
---|---|---|
PCI-6703 | SCSI | |
PCI-6704 | SCSI | |
PXI-6704 | SCSI | |
PCI-6711 | SCSI | Refer to the Known Limitations and Issues List |
PXI-6711 | SCSI | Refer to the Known Limitations and Issues List |
PCI-6713 | SCSI | Refer to the Known Limitations and Issues List |
PXI-6713 | SCSI | Refer to the Known Limitations and Issues List |
PCI-6731 | SCSI | Refer to the Known Limitations and Issues List |
PCI-6733 | SCSI | Refer to the Known Limitations and Issues List |
PXI-6733 | SCSI | Refer to the Known Limitations and Issues List |
Find the compatibility table that matches the pin count and connector type of your device. If you have questions on terminology, refer to the Glossary. After you have identified the cable and accessory options for your device from this section, move to the Known Limitations and Issues List.
Note: To help keep the size down of the compatibility tables, the terms terminal block and connector block are used interchangeably.
This section is important to review because not every cable and accessory combination allows access to the full functionality of your NI DAQ Analog Output 67xx (formerly AO Series) device or module. This list contains notes about known limitations when using certain combinations of DAQ cables and accessories. If your device or cable is not listed in this section, there are no known exceptions for it.
Model | Note |
---|---|
PCI/PXI-6711 PCI/PXI-6713 PCI/PXI-6722 PCI/PXI-6723 PCI-6731 PCI/PXI-6733 |
|
DAQCard-6715 |
|
PCIe-6738 PXIe-6738 PXIe-6739 |
|
Model | Note |
---|---|
SHC68-68-EPM | For VHDCI connections, NI recommends that you use the SHC68-68-EPM cable; however, an SH68-68-EP cable will work with NI Analog Output 67xx Models. The SHC68-68-EPM cable is a newer design featuring additional shielding and specific cable pairings to improve noise performance. |
SHC68-C68-EPM | The SHC68-C68-EPM can be used for any device or module for which the SHC68-68-EPM is recommended. The SHC68-C68-EPM is intended for custom breakout fixtures that use the VHDCI 0.8 mm connector. NI DAQ accessories only feature a SCSI 0.050 D-Type connector and will not work with this cable. |
SH68-68-EPM | For SCSI 0.050 D-Type connections, NI recommends that you use the SH68-68-EPM cable; however, an SH68-68-EP cable will work with NI Analog Output 67xx Models. The SH68-68-EPM cable is a newer design featuring additional shielding and specific cable pairings to improve noise performance. |
Review the DAQ Cable and Accessory Guides for more information about this terminology and other descriptors.
When purchasing an NI DAQ Analog Output 67xx Model device or module, for ease of use, the cables and accessories are listed on the product selection page. To begin browsing NI DAQ devices and modules, visit ni.com/daq.
You may also purchase your cables and accessories separately.
Module or Device | Cables | Accessories | ||||||
---|---|---|---|---|---|---|---|---|
Shielded | Unshielded | |||||||
Screw Terminal Block | BNC Terminal Block | Terminal Block- PXI Mounted | Screw Terminal Block – DIN Rail Mount | Screw Terminal Block | ||||
6715 | SHC68-68-EPM (Recommended, Shielded) P/N 192061-01 (1 m) P/N 192061-02 (2 m) P/N 192061-05 (5 m) P/N 192061-0R5 (0.5 m) RC68-68 (Low Cost) P/N 187252-01 (1 m) P/N 187252-0R25 (0.25 m) P/N 187252-0R5 (0.5 m) | BNC-2110 P/N 777643-01 | N/A | TBX-68 P/N 777141-01 | CB-68LP (vertical mount) P/N 777145-01 CB-68LPR (right-angle mounted) P/N 777145-02 | |||
6722, 6723 Connector 0 | SH68-C68-S (Recommended, Shielded) P/N 186381-01 (1 m) P/N 186381-0R5 (0.5 m) P/N 186381-02 (2 m) RC68-68 (Low Cost) P/N 187252-01 (1 m) P/N 187252-0R25 (0.25 m) P/N 187252-0R5 (0.5 m) | SCB-68A P/N 782536-01 | BNC-2110 P/N 777643-01 | N/A | TBX-68 P/N 777141-01 | CB-68LP (vertical mount) P/N 777145-01 CB-68LPR (right-angle mounted) P/N 777145-02 | ||
6723 Connector 1 | SH68-C68-S (Recommended, Shielded) P/N 186381-01 (1 m) P/N 186381-0R5 (0.5 m) P/N 186381-02 (2 m) RC68-68 (Low Cost) P/N 187252-01 (1 m) P/N 187252-0R25 (0.25 m) P/N 187252-0R5 (0.5 m) | SCB-68A P/N 782536-01 | N/A | N/A | TBX-68 P/N 777141-01 | CB-68LP (vertical mount) P/N 777145-01 CB-68LPR (right-angle mounted) P/N 777145-02 | ||
6738, 6739 Connector 0 & Connector 1 (if equipped) | SHC68-68-A2 (Recommended, Shielded)1 P/N 157599-01 (1 m) P/N 157599-02 (2 m) P/N 157599-0R5 (0.5 m) SH68-C68-S (Recommended, Shielded) P/N 186381-01 (1 m) P/N 186381-0R5 (0.5 m) P/N 186381-02 (2 m) RC68-68 (Low Cost) P/N 187252-01 (1 m) P/N 187252-0R25 (0.25 m) P/N 187252-0R5 (0.5 m) | SCB-68A P/N 782536-01 | N/A | N/A | TBX-68 P/N 777141-01 | CB-68LP (vertical mount) P/N 777145-01 CB-68LPR (right-angle mounted) P/N 777145-02 |
1Please review Known Limitations and Issues List for information on using this cable or accessory.
Module or Device | Cables | Accessories | ||||||
---|---|---|---|---|---|---|---|---|
Shielded | Unshielded | |||||||
Screw Terminal Block | BNC Terminal Block | Terminal Block- PXI Mounted | Screw Terminal Block – DIN Rail Mount | Screw Terminal Block | ||||
6703, 6704 | SH68-68-D1 (Recommended, Shielded) P/N 183432-01 (1 m) P/N 183432-0R4 (0.4 m) P/N 183432-02 (2 m) P/N 183432-05 (5 m) P/N 183432-10 (10 m) R6868 (Low Cost) P/N 182482-01 (1 m) P/N 182482-0R25 (0.25 m) | N/A | N/A | TBX-68 P/N 777141-01 | CB-68LP (vertical mount) P/N 777145-01 CB-68LPR (right-angle mounted) P/N 777145-02 | |||
6711, 6713 6731, 6733 | SH68-68-EPM (Recommended, Shielded) P/N 199006-01 (1 m) P/N 199006-0R25 (0.25 m) P/N 199006-0R35 (0.35 m) P/N 199006-0R5 (0.5 m) P/N 199006-02 (2 m) P/N 199006-05 (5 m) P/N 199006-10 (10 m) R6868 (Low Cost) P/N 182482-01 (1 m) P/N 182482-0R25 (0.25 m | SCB-68A P/N 782536-01 | BNC-2110 P/N 777643-01 | TB-27051 P/N 778241-01 | TBX-68 P/N 777141-01 | CB-68LP (vertical mount) P/N 777145-01 CB-68LPR (right-angle mounted) P/N 777145-02 |
1TB-2705 can only be attached directly to PXI modules front connector, and does not require a cable.