LabVIEW 2019 and 2019 SP1 Known Issues by Date

Overview

This document contains the LabVIEW 2019 and 2019 SP1 known issues that were discovered before and since the release of the LabVIEW 2018 Development System. Not every issue known to NI will appear on this list; it is intended to only show the severe and common issues.

The LabVIEW 2019 Platform Known Issues contains a full listing of known issues, including LabVIEW toolkits and modules.

Document Organization

There are two versions of the known issues list available:

Known Issues by Category
Known Issues by Date

Please refer to White Paper "LabVIEW Known Issues Categories Defined" for an explanation of the categories.


Contacting NI

You can contact us by phone, email, or the discussion forums. If you have feedback on this document, please contact NI on this NI Discussion Forum.

Known Issues by Date

The following items are known issues in LabVIEW 2019 and 2019 SP1 sorted by Date.

219819Center justified tables display improperly when overlapping with the front panel origin
39161 401FEQTLThe device ID input of the Play Sound File VI does not work on Windows
47819 3N68LE002GB file size limit of datalog files
48016 3P7CBB4QUnsigned int32 loses value in formula node when you write to the most significant bit
50420 44CG88SNUpdate the Pulse Transition Measurement Express VI
51185 47FGSQCSCannot save VI as the same name as missing library member VI
51311 477DKPBQLabVIEW does not maintain child-only item setting when dragging an item within a tree
52027 4A4GRP00Cannot use the 'New>>VI for Override...' dialog to create override of password-protected VI unless you have the password
105509The "do not save automatic changes" setting does not affect libraries
119444Multi-column listbox format lost on upgrade
120686Write to LabVIEW Measurement Files (LVM) using Express VIs takes up a lot of memory
51179 47B12U5UError 6 occurred at Create Folder in Create Directory Recursive.vi when building an application (EXE), shared library (DLL), source distribution or web service
141699NI Distributed System Manager does not show deployed libraries if they contain non-Latin characters.
128059Shared variable bindings in the same library are not updated properly when copying/renaming the library
181687Web publishing tool fails without error
163371"Save As:Copy" on a nested library breaks member VIs if use option to add copied library to owner library
168005Dynamic Variable API Does Not Support I/O Servers that Use Ranges
169840Large matrix operations that utilize the Intel MKL on Linux may crash LabVIEW
103315Creating a circular link between an Xcontrol and a LVClass can crash LabVIEW.
95055Save for previous fails if file path is too long
198717Unflatten From XML fails for cluster and arrays that consist of variants
208364LabVIEW built installers created on a 32-bit machine will not install most drivers when run on a 64-bit machine
213279Some nodes may crash or yield incorrect/inconsistent results when Inlined
208088Updating the Labels of a Cluster Written to a Chart Does Not Update the Cluster Used for Chart History
188911Control image alignment incorrect when "new report page" VI is used
227609Statically linking a LabVIEW built DLL in a C++ project results in error 998 if the DLL is not added to the Delay Loaded DLLs list
153731Unhandled Exception can occur if absolute path for system DLL used in CLFN
185890Text on a VI can be mutated to appear as Unicode
218083VIs with errors may show additional errors for code in disabled frames of Conditional Disable Structure
227030Wait on Notification from Multiple function has unexpected behavior when ignoring previous input.
229641Hang can occur when deploying RT project that has not been check out of VSS
232348Changes to a library item's access scope sometimes do not update broken callers.
235019OpenSSL fatal error when LabVIEW exits
236817NI-Auth does not work with Firefox
243468Default Namespaces not supported in XML Parsing VIs
176848Picture Control Stops Updating After Setting Properties to Default.
136677Remote panels do not work if Internet Explorer is embedded in an ActiveX or .NET Container
196607DTbl Replace Subset VI behavior change between LabVIEW 8.6.1 and 2009
236377Dropping XControl from public library breaks XControl
248914Changing the order of controls or deleting controls in a type def cluster can change references
322914Formula VI does not execute pow(x,y) function
256141Windows 7 often shows "(Not Responding)" and will bring other windows to the front during expensive operations
250588Warning Generated in a Method or Property of an XControl Appears as an Error in the Top Level VI
245148Class Properties dialog sometimes throws timeout error 123 when opening and must be restarted
251105S&V XControls built as Remote Panel crashes LabVIEW.
289842Get Variant Attribute VI returns wrong value if attribute not found
290105Text Labels in Silver Control are not in silver style
2387133D Picture Controls can display transparently or crash LabVIEW on certain graphics cards
284936Breaking one Override VI in LVOOP shows all siblings as broken but does not explain why
186808Shared Variable library on PC is undeployed if the a V in the same project is programmatically deployed to a Real-Time target
284289Source distributions with block diagrams removed prevents the use of static Shared Variable nodes.
257194Connector pane of a VI can change from LabVIEW 2009 to LabVIEW 2011
279373SMTP has been updated to use port 587; LabVIEW makes use of legacy port 25
282737Applications with Chinese characters in the executable name will throw fatal error on English Windows 7
294285Type Defined Shared Variable not found in Executable
320485User Events Created from Objects Cause Broken Packed Library VIs
314082Listbox Control With Transparent Cell Background Does not Grey Disabled Item
233061 4AQA5L00LabVIEW crashes after working with Simulation Subsystem using a LabVIEW Class
239631Memory Growth with TDMS Write
351506[Mac] Test Device option on Play Waveform Express VI Configuration page doesn't output test tone
351741Panes 'Top' pixel coordinates will vary when Windows 'Aero' is enabled/disabled
359662Some dotted scripting property calls can crash LabVIEW if earlier properties error
244551Editing large strict type definitions can take a long time to update
202192LabVIEW UDP broadcast is inconsistent across different OS's.
239719Property page doesn't update when Adapt to Source is coerced to off
245359Selecting a newer version of a .NET assembly does not reload assembly
335576Play Waveform Express VI gives error 4803 with Sample Rate 3125, 6250, 12.5K, 25K, 50K, 100K, 200K Hz
347272Executables built (without SSE2) in LV 2011 on an Intel Core Duo machine throw Error 57 when run on a machine with an AMD Athlon 3200+ processor.
353261Conditional Indexing Terminal on Parallel For Loop with Shift Registers Runs with "Memory is Full Error"
355840"Get Image" method is unreliable on .NET controls in LabVIEW (64-bit)
356656Crash when compiling VIs that call into a certain class based VI hierarchies
364338"Error while retrieving database: Forbidden" connecting to a RT target via the web configuration.
369142Front Panels may stop updating with 3+ monitors with Windows Aero enabled
377385Error 1390 on Dynamic VI Call to Friend Library
364845Streaming data to a Digital Display Chart data occasionally incorrectly displays zero even when the data is non-zero
367249It is not possible to customize the Run-Time Shortcut menu of a 3D Graph
381656Adding or subtracting timestamps causes a conversion to double and precision loss
257735Class VIs that call shared variables in a library in an auto-populating folder will not be loaded
381128The MonthCalendar .NET control automatically resizes to the incorrect size when the VI is run
305978Save As Duplicate with Include All Dependencies makes a Copy of the instr.lib Folder.
388446Eval Parsed Formula Node.vi returns incorrect results
389041Error -314250 from Create Network Stream Writer Endpoint
391455Applying an icon to LabVIEW class overwrites the icons of its methods
391784Memory Lead when Sound VIs are Called Dynamically
392545Timed Loop crashes LabVIEW after exiting
394454Data Binding: Path property can change bindings in other VI clones
3989983D Surface Axis Labes not Visible when Dialog Font Changed
399068Double Numeric Slide can not be Set to 0 when it has Defined Limits with Mouse
401421Updates to Global Variables Not Visible when Remote Debugging a LabVIEW Built Stand-Alone Application
403182Sound Output.vi Does Not Support more than 2 Audio Channels on Windows 7
403727Repeated Dynamic Calls to VI in Packed Project Library Can Cause Error in VI Call
405271Boolean Mechanical Actions Don't Work as Expected on Windows 8 Touch Screen
406311VI.Control Value.Set will Crash LabVIEW When Value Non-Variant Data is Used for Value Parameter
407614Control.Delete Method Crashes LabVIEW When Used on Grouped Pictures and Free Labels
407633Set Cell Value Method Returns Error 1604
408391Non-printable Characters in the Description of Will Corrupt LabVIEW Classes and Libraries
408790Palette Editor Cannot Add LabVIEW Classes
410360LabVIEW Classes Become Corrupt When Multiple Files With Same File Name are Added to the Class
410479Grouping ActiveX containers removes inserted ActiveX objects
410904Print.VI to Printer Method Always Prints Header in LabVIEW Built Applications
415924Double precision numeric constants set to "bar" units sometimes use Pa units
420965Adding a tooltip for a tab control after configuring the tab to show text and image can cause the tooltip to appear in the wrong position
408891Getting an Entire Column of Data from a 2D Array in the MATLAB® Script Node Returns Only 1 Element
412979Flatten to XML String does not properly escape single and double apostrophes in a string input (' and ")
422507Entering an integer into a numeric control that has a time display format does not update the control
428515On Scientific Linux 6.3 with updated Mesa Drivers, 3D Picture Controls display an inverted image
390021An inlined VI can not be placed on the block diagram of a VI with subroutine priority unless it also has subroutine priority
425313Selecting the option to hide grid lines when using Export Simplified Image with a waveform graph will not hide all grid lines when using multiple axis
430758It is not possible to save a VI with the name of another VI in memory, even if they are in different libraries
432182Custom labels on a 3D bar chart do not display properly in a 2D view
437390File Path control does not display "Browse" dialog if Start Path is an invalid network path.
428914The Y-Axis of a Mixed Signal Graph will not correctly scale when the graph is set to "Scale Object with Pane" and the user decreases the size of the VI Front Panel.
433596The 3D Surface Plot does not draw correctly when the input data is an array of the same value
458973Writing a negative number to single point float Network Shared Variables through the OPC I/O Server fails.
469268Formula Node and MathScript Node variable labels can shift to become misalligned
461969When using a class containing a DAQmx Physical Channel control, it will not properly load that information from an XML file.
468139.NET Callback Event VI keeps the Callback VI reserved even after calling a Close Reference VI is called
384591A password protected VI accessing a password protected community scoped VI is broken if the VIs are set to separate compiled code from source code
478232In certain cases, LabVIEW may incorrectly crisscross wires during loop creation
470218LabVIEW (64-bit) for Mac, does not show the login prompt for Revision History when starting LabVIEW
420582Typing Obtain in Quick Drop populates with an unexpected selection
442745RF-RIO Instr Default Personality 5646R.lvproj's FPGA VI will hang on save.
462021In LabVIEW for Mac, filtered menu tracking is not cancelled until the event's case finishes executing
480386ActiveX call to open PDF (Adobe Reader 11.0.07) results in LabVIEW crashing
401078Opening any non-VI dialog, such browse for files or one button dialog, may block web service requests from executing.
467735"Format into File" produces Error 1 when appending to a file that has a size of 4 GB
492341LabVIEW TDMS Advanced Asynchronous Write does not return error when target disk is full.
485336Deleting a second y-axis on a waveform graph with a cursor crashes LabVIEW
493624Change of .NET assembly version requires manual relink of static class methods/properties
493662.NET Constructor Node cannot differentiate between functions with different enums at the same position
507856Replacing an Intensity Graph with z-axis autoscaling enabled with a Waveform Graph or XY Graph causes LabVIEW to crash
510218Create Mask.vi does not work in conjunction with the Get Image Subset.vi in LabVIEW
515300NamedBundler function in LV Scripting does not work properly when the reference is opened from a New VI function
584837Mass compiling a project from project explorer in certain cases can cause LabVIEW to hang.
570754Linear Fit produces NaN result if X input value is too large
457854Aborting a VI can leave VIs targeted by a Call By Reference node reserved permanently
504716Advanced Asynchronous Write function does not return an error when target disk is full or removed
509876Bundle by Name function can send wrong pointer into subVI with Call Library Function Node
521856Rare LabVIEW crash when using "Panel Close?" filtering event and "Quit LabVIEW" function
529278MATLAB Script Node can output different data in LabVIEW 32-bit vs. 64-bit
544257Inplace issue can occur when using LabVIEW 32-bit on a 64-bit operating system.
544623LabVIEW 64-bit for Mac OS can improperly create special characters.
552304SMTP Client VI Example incorrectly converts some characters when placed in subject line
558774Constructor node for FolderDialogBox from Windows.System.Forms (4.0.0) causes hang during execution
558891In some scenarios, LabVIEW Menu positions within a VI or project are offset in Windows 10
565884When creating .NET assemblies in LabVIEW, 1-dimension arrays of doubles or strings are represented as 2-dimension arrays of rank 1
570102Calling the "Web Server: Server Active" property causes a small memory leak.
571353XNode can cause Dirty Dot when no parameters are modified
574329Error 4 thrown in executable but not in development environment
576990Assembly created by Web Service Importer from WSDL throws error 1172
578085Saving a very large VI in LabVIEW 2015 and later can take longer than in previous versions
583670If LabVIEW 2016 is installed, installers built in any version of LabVIEW will not work on Windows 7 RTM and older
584455Certain Silver Controls appear differently on Front Panel versus Print Output
585867LabVIEW 64-bit can crash while closing a VI containing certain ActiveX containers
634531Template methods in a C++ DLL do not appear in the Function Name drop down list of the Call Library Function Node.
3171173D Surface Graph incorrectly blends colors when interpolating
432523Reordering elements of a cluster within the private data of a class can break VIs that reference the class
590224In some cases, using an XControl in a PPL can cause LabVIEW to hang
596788The struct ErrorCluster from InteropAssembly throws case sensitivity error in Visual Basic
599746When building a web service into an EXE and making an installer, some software dependencies are not automatically selected as additional installers
602529Open/Create/Replace File does not return an error when attempting to create a file name that is restricted by the OS
603204When using a cylindrical coordinate system on a 3D scatter plot, the color ramp legend does not reflect the displayed color gradient
606191Building a .NET Interop Assembly with an array of classes as an output fails
607058Flattening an EXT representation numeric to JSON causes loss of precision
607411When using a LabVIEW-built .NET Interop Assembly in an ASP .NET application, the first call to the assembly will return a NullReferenceException
613423Registering for an event for multiple boolean controls can fail in specific configurations
614154Renaming a shared variable with a special character in its name (ö/ü/ä/ß) fails when the project is reopened
616849LabVIEW files are saved without an extension after attempting to save with an invalid character
617826LabVIEW will not generate a Key Down event if the mouse is held down on a cell inside a table control
618568Reference leaks with the Audio DataPlugin
624802Setting binding properties of a control within a preallocated clone subVI or XControl sets the property for all instances of the subVI or XControl
625718The Web Publishing Tool has incompatibility issues with Internet Explorer 11
627783Using TCP Open Connection with a Timeout of 0 can cause connection failures
629032Wiring a 2D array with an empty string to the property names input of the TDMS Set Properties function causes data for that channel to be unreadable
631762Using Export data to Excel on a Waveform Chart that contains an empty waveform can cause LabVIEW to crash
633309Waveform graphs can resize at runtime
634015Certain operations will not let the System Exec VI return on Windows 10
634287Incorrect behavior when creating a .NET Interop Assembly with typedefs
638070LabVIEW crashes when calling the Children[] Property Node in a VI with reentrancy set to "Shared clone reentrant execution."
639524Changing font to Application font can shrink constants inside of structures
640089DETT reports a reference leak when using the Open Data Storage express VI and Close Data Storage express VI
640243XY graph pointers do not copy correctly using Copy Data operation
633648LabVIEW crashes when replacing the Actor Framework library with a packed library
634261The Block Diagram.Get Image Scaled method displays subVIs as black rectangles if the image depth is less than 8.
647354Opening a new shared variable connection can block reading from other connected variables
652898LabVIEW crashes when attempting to open detailed help for an EXE
655865The VI Method Save.For Previous fails to maintain the status of the "Separate compiled code from source file" attribute
674079Packed Libraries that have debugging enabled and use XNodes load slowly
674968LabVIEW does not automatically detect the LabWindows/CVI Runtime installer as a required dependency when building an installer from an EXE that requires the LabWindows/CVI Runtime
676013LVMerge returns error 53 when the VI has a dependency on an XControl
678334Changing the keyboard shortcut of the Bookmark Manager to Ctrl+Shift+3 does not launch the Bookmark Manager when the shortcut is pressed.
339230Newly created typedefs are not automatically added to library
678964Nested XControls require recompile when built into Packed Project Libraries
686923Bring to Front Invoke Node may not bring window to front
631422Regenerate Channel Instances stop responding
670209Changing XControl state may lock XControl permanently
677020Channel wires do not automatically update minor changes in core data type (Not A Bug)
688771Cannot add CA-signed certificates to LabVIEW Web Services
684847Nested PPL VIs cannot be found when debugging built executable
706182Mass Compile causes LabVIEW crash
691608Match Pattern primitive does not find matches if the Input String is empty.
703331LabVIEW Built Application will crash at launch if contained in a folder that has any character not supported in the system codepage
701859[Linux Red Hat 6.x] libniPythonInterface.so* symlinks are set to absolute paths
704478Adding array manipulation functions between signed and unsigned numeric arrays incorrectly removes coercion dots
706545Clicking greyed out option of the Scale Legend when using a Waveform Chart causes LabVIEW to crash
706578LabVIEW RTE crashes when calling a VI that calls an ActiveX object
715295DataSocket Write VI with default timeout can hang before proceeding
723354Remote debugged EXE returns error when attempting to save class changes
724157[Linux] Build Specifications in Shipping examples may not be runnable by double-clicking
727256LabVIEW doesn't make a local copy of lvanlys.dll when building a PPL
729952Get Date/Time String does not work for dates beyond 2/5/2040
732570System decoration frame bleeds through system checkbox boolean text

 

Known Issues

IDKnown Issue
219819

Return
Center justified tables display improperly when overlapping with the front panel origin
When you add a table control to the front panel so that it overlaps with the vertical origin of the front panel, LabVIEW displays center justified columns off center when you type text. The cells appear to float or move horizontally until aligned with the vertical origin. Formerly tracked as 50061 and 42NAR8SA

Workaround: Move the table away from the front panel's vertical origin.

Reported Version: 8.0.1  Resolved Version: N/A  Added: 09/01/2007
39161
401FEQTL

Return
The device ID input of the Play Sound File VI does not work on Windows
On Windows, LabVIEW ignores the device ID input of the Play Sound File VI. This VI plays sound only on the default sound card.

Workaround: Use the Sound Output Configure VI and the Sound Output Write VI with the Sound File Open VI and the Sound File Read VI or the Sound File Simple Read VI. Refer to the Sound File to Sound Output example VI for an example of this workaround.

Reported Version: 8.0.1  Resolved Version: N/A  Added: 09/01/2007
47819
3N68LE00

Return
2GB file size limit of datalog files
The maximum size of datalog files is 2 GB.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 09/01/2007
48016
3P7CBB4Q

Return
Unsigned int32 loses value in formula node when you write to the most significant bit
If you wire a hex value greater than x7FFFFFFF as an unsigned, 32-bit integer to a Formula Node, LabVIEW coerces the value to 0. If you use a negative number for U32 input/output variable, LabVIEW will coerce the value to 0.

Workaround: 1. Use the Mathscript node or LabVIEW code for the operation that involves an unsigned, 32-bit integer.
2. Use signed 32-bit integers instead of unsigned 32-bit integers in the formula node.

Reported Version: 8.0  Resolved Version: N/A  Added: 09/01/2007
50420
44CG88SN

Return
Update the Pulse Transition Measurement Express VI
The terminology and measurement definitions for the Transition Measurements VI comply with IEEE Standard 181-2003, IEEE Standard on Transitions, Pulses, and Related Waveforms. However, the Timing and Transition Measurements Express VI does not comply with this IEEE Standard.

Workaround: The Slew rate refers to the transition slope. The Preshoot refers to the pre-transition undershoot (rising pulse) or the pre-transition overshoot (falling pulse). The Overshoot refers to the post-transition undershoot (rising pulse) or the post-transition overshoot (falling pulse).

Reported Version: 8.5  Resolved Version: N/A  Added: 09/01/2007
51185
47FGSQCS

Return
Cannot save VI as the same name as missing library member VI
If a library contains a VI and the VI is missing, you should be able to save a VI as the same name as the missing VI in order to rebuild the missing VI. Currently, LabVIEW does not allow this.

Workaround: Delete the item from the library, save the new VI as the same name as the missing VI and then move the VI into the library.

Reported Version: 8.5  Resolved Version: N/A  Added: 09/01/2007
51311
477DKPBQ

Return
LabVIEW does not maintain child-only item setting when dragging an item within a tree
If you have a tree item with the child-only setting, and then drag it within the tree, LabVIEW loses the child-only setting.

Workaround: Use tree events to (1) get the child-only flag setting when the user begins a drag, and (2) reset the child-only flag after completing a drop.

Reported Version: 8.2.1  Resolved Version: N/A  Added: 09/01/2007
52027
4A4GRP00

Return
Cannot use the 'New>>VI for Override...' dialog to create override of password-protected VI unless you have the password
You use the 'New>>VI for Override...' dialog to override an ancestor VI in a LabVIEW class if the VI you want to override is password-protected.

Workaround: Make a public VI which wraps the functionality of the private VI, and instruct others to override the public VI.

Reported Version: 8.5  Resolved Version: N/A  Added: 09/01/2007
105509

Return
The "do not save automatic changes" setting does not affect libraries
The "do not save automatic changes" options setting does not affect any type of library, including classes.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 06/20/2008
119444

Return
Multi-column listbox format lost on upgrade
A Multicolumn listbox created in LV 7.1 may lose its format when opened in LV 8.5 or later. Column headers lose their 3D appearance and font formatting might be lost.

Workaround: Replace the Listbox and recreate all customizations

Reported Version: 8.5  Resolved Version: N/A  Added: 07/12/2008
120686

Return
Write to LabVIEW Measurement Files (LVM) using Express VIs takes up a lot of memory
The "Write to Measurement File" Express VI consumes a large amount of memory when writing to a Text File (LVM). However, the memory usage is smaller when the same Express VI is used to write a TDM/TDMS File

Workaround: Use general LabVIEW VIs (and not Express VIs) to perform an LVM write for large amounts of data. The other option would be to write in smaller chunks.

Reported Version: 7.1  Resolved Version: N/A  Added: 08/11/2008
51179
47B12U5U

Return
Error 6 occurred at Create Folder in Create Directory Recursive.vi when building an application (EXE), shared library (DLL), source distribution or web service
When building a Build Specification, the build process fails with Error 6 at Create Folder in Create Directory Recursive.vi. This usually happens if the path one of the files generated by the build (temporarily during the build process or as part of the output) is too long. The operating system requires paths for files to be less than 255 characters.

Workaround: 1. Use a shorter path for your build destination (i.e. c:\build\) and if necessary copy the output to the final location you need.
2. A. For application (EXE) and shared library (DLL) build specifications, place a checkmark in the Use LabVIEW 8.x file layout checkbox on the Advanced page of the Properties dialog box.
2. B. For source distribution or web service build specifications, uncheck the Preserve disk hierarchy checkbox on the problem Destination on the Destinations page of the Properties dialog box.

Reported Version: 8.2.1  Resolved Version: N/A  Added: 10/06/2008
141699

Return
NI Distributed System Manager does not show deployed libraries if they contain non-Latin characters.
If a library with non-Latin characters (such as Japanese, Chinese, or Korean) is deployed, it will not show up in the NI Distributed System Manager tree view.

Workaround: Rename the library using only the Latin alphabet and re-deploy the library.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 02/10/2009
128059

Return
Shared variable bindings in the same library are not updated properly when copying/renaming the library
If you have shared variables in a library which are bound to I/O servers or other variables that are also in the same library, and you rename or save a copy of the library, the bindings still refer to the original library name.

Workaround: Manually rebind the variables after copying or renaming the library.

Reported Version: 8.0  Resolved Version: N/A  Added: 04/28/2009
181687

Return
Web publishing tool fails without error
The web publishing tool may fail to start the web server if the port is already reserved, yet not return an error.

Workaround: Ensure that the port to be used by the web server is not in use.

Reported Version: 8.6  Resolved Version: N/A  Added: 08/03/2009
163371

Return
"Save As:Copy" on a nested library breaks member VIs if use option to add copied library to owner library
Old Description :
"Save As:Copy" on a nested library breaks member VIs if use option to add copied library to owner library

If you have a nested library, a library that is owned by another library, and you use Save As:Copy, there is an option to add the duplicate library to the original owner library. If you use this option, the member VIs of the duplicate library are all broken because they are not correctly named as members of the owning library.
This bug affects all types of libraries, .lvlib, .lvclass, .xctl and .lvsc.

Workaround: Option 1: Do not use the "add to owning library" option and instead add the duplicate library to the owner manually after the copy.

Option 2: After the copy operation, open and close one of the new VIs and then move the duplicate library out of the owner library. Browse to any missing VIs that pop up a browse dialog. Move the duplicate library back into the owner library.

Reported Version: 8.5  Resolved Version: N/A  Added: 09/30/2009
168005

Return
Dynamic Variable API Does Not Support I/O Servers that Use Ranges
You cannot use the Variable classes, properties, and methods or the associated Shared Variable functions (Dynamic Variable API) to dynamically read and write PSP items published by an I/O Server that uses a Range item. For example, Modbus I/O Servers and Lookout Ranges are affected by this issue.

Workaround: If you want to use the Dynamic Variable API to read or write one of these PSP items, you can create a network-published shared variable and bind it to the PSP item. Then you can use the Dynamic Variable API to read and write the bound shared variable.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 11/10/2009
169840

Return
Large matrix operations that utilize the Intel MKL on Linux may crash LabVIEW
When one or more matrix operations consumes most of the system resources, the Intel MKL library produces an unhandled exception that results in a LabVIEW application crashing.
This Intel library is used to accelerate fundamental linear algebra operations performed under Linux operating systems. This issue has been reproduced outside the LabVIEW execution environment and a bug report has been submitted to Intel.
Because the crash is tied to system resources, it can manifest itself in many ways. For example, we have reliably reproduced the problem by:
1. Decomposing a large matrix into multiple large matrices.
Specific example: Computing the singular value decomposition (SVD) of a 2500-by-2500 matrix on a system with 256M RAM.
2. Simultaneously computing multiple matrix operations using relatively small matrices.
Specific example: Computing 30 matrix expressions using 300 x 300 matrices on a system with 512 MB RAM.

Workaround: If you have identified one or more matrix operations in your application that exhibit this behavior, you have multiple options to avoid crashing.

1. Serialize the matrix operations so that they are not consuming resources in parallel.
2. Replace affected matrix arithmetic functions using Basic Linear Algebra Subroutine (BLAS)functions found on the BLAS palette.
3. Structure your application so that these operations are not competing with other functions for system resources.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 11/10/2009
103315

Return
Creating a circular link between an Xcontrol and a LVClass can crash LabVIEW.
The circular load leads to VIs that are permanently broken and no matter what you do the run arrow will not become fixed.

Workaround: Do not create a circular link from your XControl to your class. In other words, write your class completely and then write your XControl using the class. Do not put the XControl or any property/invoke node for the XControl into member VIs of the class.

Reported Version: 8.5.1  Resolved Version: N/A  Added: 11/17/2009
95055

Return
Save for previous fails if file path is too long
Save for previous copies the folder being saved to a temp location; if the resulting file paths exceed the limit defined by the OS, the function fails.

Workaround: Copy the folder being saved to the root directory to reduce the file path length and Save for Previous from that location.

Reported Version: 8.5  Resolved Version: N/A  Added: 11/17/2009
198717

Return
Unflatten From XML fails for cluster and arrays that consist of variants
Creating a cluster that contains a variant or building an array of variants, and then trying to flatten it to XML using the Flatten To XML VI and then unflattening it using the Unflatten From XML VI will throw error 1106

Workaround: N/A

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 02/01/2010
208364

Return
LabVIEW built installers created on a 32-bit machine will not install most drivers when run on a 64-bit machine
If you build an installer using LabVIEW on a 32-bit machine that contains National Instruments drivers, the corresponding drivers will not be installed if the installer is run on a 64-bit machine. Drivers such as NI-DAQ, NI-Sync etc. are affected by this issue. Installation on 32-bit machines are not affected by this bug.

Workaround: On the deployment 64-bit machine, download and install the missing drivers from the ni.com Drivers and Updates page

Reported Version: 8.5  Resolved Version: N/A  Added: 02/16/2010
213279

Return
Some nodes may crash or yield incorrect/inconsistent results when Inlined
An Inline public methodVI calling a private-scope method VI, inlined into a non-class caller may give a runtime error when trying to call the private method from the inlined code in the non-class caller.

Workaround: Do not try to Inline VIs with these nodes.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 02/19/2010
208088

Return
Updating the Labels of a Cluster Written to a Chart Does Not Update the Cluster Used for Chart History
Changing the Label of elements in a cluster written to the Waveform Chart does not update the label of the cluster when read from the Waveform Chart Data History Property.

Workaround: Temporarily wire up a completely different data type to the Waveform chart indicator and then rewire the original cluster. The changes will now propagate to the Chart History.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 03/09/2010
188911

Return
Control image alignment incorrect when "new report page" VI is used
When using Append Control Image to Report.vi, the alignment of some images are ignored when New Report Page.vi is used between appended images. This problem only exists with Office 2007. Other versions - Office 2003 and Office 2010 do not exhibit this behavior.

Workaround: Use a New Report Line.vi between appending the image and the New Page.vi

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 06/16/2010
227609

Return
Statically linking a LabVIEW built DLL in a C++ project results in error 998 if the DLL is not added to the Delay Loaded DLLs list
For more information see this KnowledgeBase

Workaround: Go to the Project Property Pages, Configuration Properties»Linker»Input and add the name of your DLL to the Delay Loaded DLLs list.

Reported Version: 7.1.1  Resolved Version: N/A  Added: 06/16/2010
153731

Return
Unhandled Exception can occur if absolute path for system DLL used in CLFN
If you use a specific path to a system DLL (C:\windows\system\user32.dll) and build your VI into an application it will create a copy of the DLL inside the application. This can cause an unhandled exception when running

Workaround: LabVIEW searches in the system directory when looking for DLLs. If you are using a system DLL simply put the name in the in DLL Path box in the CLFN properties. In the example above you would simply put "user32.dll"

Reported Version: 8.6  Resolved Version: N/A  Added: 07/23/2010
185890

Return
Text on a VI can be mutated to appear as Unicode
After building a project into an executable, various text for controls and indicators changes languages. It appears that the text was interpreted as Unicode.

We have not been able to reproduce this in house to find a definite cause. Because of this we will leave this CAR open even though we have created code to recover from the corruption if it happens.
Previously tracked as CAR 179683

Workaround: Upgrade the VI to LabVIEW 2011. In 2011 we put in code to only view text on VIs as unicode if the UseUnicode=True is in the LabVIEW .ini file. Previously this would only switch on the ability to change something to unicode.

When the VI is upgraded to 2011 it should be saved and then saved for previous to return it to the original version.

Reported Version: 8.6.1  Resolved Version: N/A  Added: 07/23/2010
218083

Return
VIs with errors may show additional errors for code in disabled frames of Conditional Disable Structure
If you have a VI that has errors in it, there may be additional errors shown. The errors will be in code that is inside of a disabled frame of the Conditional Disable Structure (in the "Default" or "Windows" frame when on RT).

Workaround: Fix the other errors in the VI, and the additional errors should go away.

Reported Version: 2010  Resolved Version: N/A  Added: 07/23/2010
227030

Return
Wait on Notification from Multiple function has unexpected behavior when ignoring previous input.

Workaround: See KB

Reported Version: 8.0  Resolved Version: N/A  Added: 07/23/2010
229641

Return
Hang can occur when deploying RT project that has not been check out of VSS
When using VSS source code control for a real time project and trying to deploy code that has not been checked off the deployment window blocks a pop up from VSS saying that the code has not been checked out. The deployment status window is modal so it does not allow you to select to proceed in the VSS window.

Workaround: In the LabVIEW project properties disable the prompts from source code control. Or you could make sure that the VIs are saved prior to deploying.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 07/23/2010
232348

Return
Changes to a library item's access scope sometimes do not update broken callers.
Changing a library item's access scope sometimes does not update callers which are broken only because they were attempting to access an item which was out of scope to them.

Workaround: Force recompile (ctrl+click on the run arrow) any VI which incorrectly believes that access scope forbids access to it's dependency. Changing the access scope to another value, then back to the desired value while the VI is open will also fix the issue.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 07/23/2010
235019

Return
OpenSSL fatal error when LabVIEW exits
The OpenSSL fatal error possibly occurs when using Search features in LabVIEW for the first time after installation.

Workaround: Launch LabVIEW and exit when Getting Started Window opens. The error now goes away in future launchings.

Reported Version: 2010 32-bit  Resolved Version: Unknown  Added: 08/03/2010
236817

Return
NI-Auth does not work with Firefox
Web Services using NI-Auth work incorrectly in Firefox. A user's log in credentials will never be accepted.

Workaround: Use Internet Explorer

Reported Version: 2010 32-bit  Resolved Version: Unknown  Added: 08/03/2010
243468

Return
Default Namespaces not supported in XML Parsing VIs
When trying to work with XML Parsing VIs you will get error -2768

Possible reason(s):
LabVIEW: The XPath expression does not conform to XPath syntax. Refer to the W3C
XPath Web site at http://www.w3.org/TR/xpath for more information about XPath syntax.

Workaround: Remove the default namespace (example: remove xmlns="http://www.ieee.org/ATML/2007/TestResults"),

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 08/17/2010
176848

Return
Picture Control Stops Updating After Setting Properties to Default.
Once the picture control's values have reinitialized to default by selecting Data Operations»Reinitialize to Default or programmatically using the method Reinitialize to Default, the mouse position property node stops updating.

Workaround: Replace the picture control with a new one from the palette.

Reported Version: 8.6.1  Resolved Version: N/A  Added: 09/24/2010
136677

Return
Remote panels do not work if Internet Explorer is embedded in an ActiveX or .NET Container
If a remote panel is built in LabVIEW 8.6 and embedded in an ActiveX or .NET Container in a LabVIEW 8.6 VI it will not display correctly

Workaround: Use a remote subpanel. This is actually the recommended way to accomplish this task

Reported Version: 8.6  Resolved Version: N/A  Added: 10/01/2010
196607

Return
DTbl Replace Subset VI behavior change between LabVIEW 8.6.1 and 2009
The start input indexes from the replacement data instead of the existing data

Workaround: Set the index of data to replace from 0

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 10/01/2010
236377

Return
Dropping XControl from public library breaks XControl
When adding an X control from a public library into the controls palette, it become broken when dropped down to the front panel from the controls palette.

Workaround: Include a merge VI in the functions palette

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 10/01/2010
248914

Return
Changing the order of controls or deleting controls in a type def cluster can change references
When you create a reference for a control in a type defined cluster LabVIEW uses the cluster order to determine what control the reference is referring to. Say you have a type defined cluster with elements A, B, C and D with cluster order 1,2,3 and 4 respectively. On the block diagram of a VI you have control references to each of the controls. If you open the type def and delete control C the block diagram of the VI will only contain 3 references. Moreover, the reference that used to be for control C will now reference control D. This is because the control is based on cluster order

Workaround: N/A

Reported Version: 7.1.1  Resolved Version: N/A  Added: 10/01/2010
322914

Return
Formula VI does not execute pow(x,y) function

Workaround: Use the formula node to use the pow(x,y) function. If you need to change this programmatically, use the Power of X function in G code.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 10/01/2010
256141

Return
Windows 7 often shows "(Not Responding)" and will bring other windows to the front during expensive operations
If Windows 7 if a window is unresponsive to user input (e.g. mouse clicks) for five seconds it will ghost the window and display "(Not Responding)".

Some operations in LabVIEW run in the UI thread. This is to prevent different operations from happening in parallel (e.g. compiling, edit operations, saving, drawing, etc.). Because large block diagrams can take longer than five seconds to compile or run clean up on Windows can tag LabVIEW as Not Responding.

In some cases the ghosted window can move behind the other open windows when it finishes it task.

Workaround: Wait until the expensive task as finished before trying to interact with the window.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 10/28/2010
250588

Return
Warning Generated in a Method or Property of an XControl Appears as an Error in the Top Level VI
If you create a method or a property in an Xcontrol in which you have implemented code to generate a warning it is transformed into an error in the calling VI.

Workaround: In the VI look for specific error and transform back to a warning

Reported Version: 8.5.1  Resolved Version: N/A  Added: 11/02/2010
245148

Return
Class Properties dialog sometimes throws timeout error 123 when opening and must be restarted
In LV 2010, there appears to be a timing race condition in the Class Properties dialog for LabVIEW classes. Every once in a while if you try to launch the dialog, the dialog will throw an error dialog reporting error 123 that the dialog has timed out while trying to launch. After you dismiss the dialog, you may see a secondary error dialog. Once you dismiss that, you can relaunch the Class Properties dialog and will generally succeed. There is no danger to your class and no corruption to you class file has occurred. It is solely a bug in trying to launch the dialog.

Workaround: Hit Continue or OK button to dismiss all error dialogs that come up then retry opening the Class Properties dialog.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 02/18/2011
251105

Return
S&V XControls built as Remote Panel crashes LabVIEW.
Remote panels do not reliably support the Sound and Vibration XControls.

Workaround: Use another mechanism for remote viewing.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 02/18/2011
289842

Return
Get Variant Attribute VI returns wrong value if attribute not found
The default value that's returned by the Get Variant Attribute VI is not blank when nothing is wired to the default value terminal. The Get Variant Attribute instead seems to return the last/previous value it returned as the default value.

Workaround: Use the Found? output and logic to return a blank variant if necessary

Reported Version: 8.6.1  Resolved Version: N/A  Added: 03/21/2011
290105

Return
Text Labels in Silver Control are not in silver style

Workaround: N/A

Reported Version: 2011 32-bit  Resolved Version: N/A  Added: 04/05/2011
238713

Return
3D Picture Controls can display transparently or crash LabVIEW on certain graphics cards
The 3D Picture Control is built on a OpenSceneGraph which uses OpenGL. Several reports of the 3D picture control crashing LabVIEW have been reported. In almost all cases it was an Intel integrated graphics card involved. This crash is caused by an incompatibility of the graphics hardware.

Note: Many of the 3D Graphs use the 3D Picture Control

Workaround: There have been several things that have worked for users:
  •  
  • Update the video driver
  •  
  • Turn on/off hardware acceleration
  •  
  • Turn on Aero in Windows 7
  •  
  • Turn off Aero in Windows 7
  •  


Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 04/20/2011
284936

Return
Breaking one Override VI in LVOOP shows all siblings as broken but does not explain why
When using OOP in LabVIEW, breaking the connector pane of a child class Override VI will make all of its sibling override VI's appear broken even though they are not broken. Hitting run on the broken Run Arrow of any child class Override VI will list all of the child class VIs in the list of "Items with Errors", but none of them will have an error associated with it except for the broken ones.

Workaround: Use the red X in the errors window to find the actual broken VI

Reported Version: 8.6.1  Resolved Version: N/A  Added: 04/20/2011
186808

Return
Shared Variable library on PC is undeployed if the a V in the same project is programmatically deployed to a Real-Time target
When programmatically deploying a VI to a Real-Time target the Shared Variable library residing in the same project as the deployed VI will be undeployed.

Workaround: Programmatically deploy the shared variable library on the PC after deploying the VI to the real-time controller.

Reported Version: 2009 32-bit  Resolved Version: N/A  Added: 07/20/2011
284289

Return
Source distributions with block diagrams removed prevents the use of static Shared Variable nodes.
Source distributions that include static Shared Variable nodes with block diagrams removed will return the following error at run-time, "VI has a bad connection to or cannot find a subVI or external routine."

Workaround: Use the Programmatic Shared Variable API or do not remove the block diagrams.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 07/20/2011
257194

Return
Connector pane of a VI can change from LabVIEW 2009 to LabVIEW 2011
If you have a VI with no items in the connector pane and upgrade it straight form LabVIEW 2009 to LabVIEW 2011 then the connector pane may change

Workaround: Open in LabVIEW 2010 first

Reported Version: 2011 32-bit  Resolved Version: N/A  Added: 08/02/2011
279373

Return
SMTP has been updated to use port 587; LabVIEW makes use of legacy port 25
The SMTP has been updated to use port 587 instead of port 25. LabVIEW still makes use of port 25 with its SMTP VIs.

Workaround: Open any SMTP VI, and find the SMTP_CreateSession.vi. Open that VI, you will find a numeric constant on the block diagram that is set to 25.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 08/02/2011
282737

Return
Applications with Chinese characters in the executable name will throw fatal error on English Windows 7
N/A

Workaround: Use a different name for the executable.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 08/02/2011
294285

Return
Type Defined Shared Variable not found in Executable
When a VI is made with the following conditions:

1) Uses a Shared Variable attached to a type definition
2) The type defined control (attached to the shared variable) is not in the main project directory (ie, it is in a different folder)
3) The VI uses dynamic data (or waveform to dynamic data function)

A created executable seems to not include the *.ctl file defining the shared variable type.

This missing type definition causes the run time engine, when starting the executable, to search for and (if the control is not located in the searched directories) fail to find the *.ctl file. If the location of the *.ctl file is specified, the executable runs without issues.

Workaround: Disconnect from Type Def during the build.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 08/02/2011
320485

Return
User Events Created from Objects Cause Broken Packed Library VIs
If you are using an object as a user event, it works fine while in the LabVIEW environment. However, when compiled into a packed library, the user event refnum has a broken wire.

Workaround: N/A

Reported Version: 2010 SP1 32-bit  Resolved Version: N/A  Added: 08/02/2011
IDKnown Issue
314082

Return
Listbox Control With Transparent Cell Background Does not Grey Disabled Item
n/a

Workaround: Make the background color of the cells match the background of the panel, instead of making them transparent.

Reported Version: 2011 32-bit  Resolved Version: N/A  Added: 09/07/2011
233061
4AQA5L00

Return
LabVIEW crashes after working with Simulation Subsystem using a LabVIEW Class
Sometimes LabVIEW will crash after working with a Simulation Subsystems that has a LabVIEW Class as one of its controls or indicators on its connector pane. Usually it is only a problem when working with the Subsystem's caller within a LabVIEW Project. The crash will occur after closing the project, while returning to the initial LabVIEW window.

Workaround: Save all work before closing the LabVIEW Project when using LabVIEW Simulation and Classes together.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 11/10/2011
239631

Return
Memory Growth with TDMS Write
With the standard TDMS API, when TDMS Write VIs are executed the API will build a cache in memory. This may present as a memory leak, as this memory is only cleared in specific situations.

Workaround: See KnowledgeBase 5WQD51YS: Memory Growth with TDMS Write for more information.

Reported Version: 2009  Resolved Version: N/A  Added: 04/27/2012
351506

Return
[Mac] Test Device option on Play Waveform Express VI Configuration page doesn't output test tone
N/A

Workaround: N/A

Reported Version: 2011 32-bit  Resolved Version: N/A  Added: 05/07/2012
351741

Return
Panes 'Top' pixel coordinates will vary when Windows 'Aero' is enabled/disabled
If the Windows Vista/7 option to "Use visual styles on windows and buttons" is enabled, a VI property node for Front Panel Window:Panel Bounds will return a different 'Top' value.

Workaround: If you are calculating the position of elements within your VI based on this value, check the deployed OS, and subtract an offset value.

Reported Version: 2011 32-bit  Resolved Version: N/A  Added: 05/07/2012
359662

Return
Some dotted scripting property calls can crash LabVIEW if earlier properties error
If you access the property LinkedControl.ClassName on an object that does not have a linked control error 1308 will be thrown. If you access the property 3 times, LabVIEW will crash.

Workaround: Separate into two calls; e.g. change a property of LinkedControl.ClassName into a call to LinkedControl, which emits a reference and, if successful, wire that to a second property node to get ClassName.

Reported Version: 2010 SP1 32-bit  Resolved Version: N/A  Added: 07/11/2012
244551

Return
Editing large strict type definitions can take a long time to update
When large type definitions are updated, all instances in memory require an update. This update can take many minutes for very large type definitions.

Workaround: Use smaller type definitions, or consider using LabVIEW classes to contain your type data.

Reported Version: 7.1.1  Resolved Version: N/A  Added: 07/23/2012
202192

Return
LabVIEW UDP broadcast is inconsistent across different OS's.
If the UDP Open VI has 0.0.0.0 wired to the Net Address terminal, the behavior varies with OS. Windows XP and NI ETS will send on all interfaces, while Windows Vista, Windows 7, VxWorks, and Linux will send on the default interface.

Workaround: N/a

Reported Version: 8.6.1  Resolved Version: N/A  Added: 07/24/2012
239719

Return
Property page doesn't update when Adapt to Source is coerced to off
If you have a FXP constant with Adapt to Entered Data set and make any modifications to the display format, the resulting constant will not be set to adapt. The property page will not reflect this change before it is closed.

Workaround: Always double-check condition of Adapt To Entered Data.

Reported Version: 2010  Resolved Version: N/A  Added: 08/03/2012
245359

Return
Selecting a newer version of a .NET assembly does not reload assembly
Changing a constructor from an old version of a .NET assembly to a newer version at edit time does not cause the new assembly to be loaded and consequently none of the new functionality is available.

Workaround: 1. Remove the old assembly so the .NET Runtime is not able to find it. It will then return the updated version to LabVIEW.

2. Load the new assembly in a blank VI before opening your existing VI. This will load the new version into memory prior to you requesting the older version.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 08/03/2012
335576

Return
Play Waveform Express VI gives error 4803 with Sample Rate 3125, 6250, 12.5K, 25K, 50K, 100K, 200K Hz
n/a

Workaround: Instead of using the "Play Waveform" Express VI, use the code from the example Generate Sound.vi.

Reported Version: 2010 SP1 32-bit  Resolved Version: N/A  Added: 08/03/2012
347272

Return
Executables built (without SSE2) in LV 2011 on an Intel Core Duo machine throw Error 57 when run on a machine with an AMD Athlon 3200+ processor.
n/a

Workaround: Build the executable on the Athlon 3200+ computer.

Reported Version: 2011 32-bit  Resolved Version: N/A  Added: 08/03/2012
353261

Return
Conditional Indexing Terminal on Parallel For Loop with Shift Registers Runs with "Memory is Full Error"

Workaround: Use the Build Array in a Case structure

Reported Version: 2012 32-bit  Resolved Version: N/A  Added: 08/03/2012
355840

Return
"Get Image" method is unreliable on .NET controls in LabVIEW (64-bit)
Calling the 'Get Image' method on a .NET control works correctly on 32-bit versions of LabVIEW, but will fail to return an image intermittently when LabVIEW (64-bit).

Workaround: n/a

Reported Version: 2011 64-bit  Resolved Version: N/A  Added: 08/03/2012
356656

Return
Crash when compiling VIs that call into a certain class based VI hierarchies
Some VIs that call into a formerly non-dynamic dispatch member of a class whose parent is missing may crash when saved or mass compiled.

Workaround: Open the class first, then open the VI and save it.

Reported Version: 2011 32-bit  Resolved Version: N/A  Added: 08/03/2012
364338

Return
"Error while retrieving database: Forbidden" connecting to a RT target via the web configuration.
If you change the admin password for an RT target and reboot the target before saving, you may receive the error "Error while retrieving database: Forbidden."

Workaround: Refresh the web page hosting the web configuration.

Reported Version: 2012  Resolved Version: N/A  Added: 08/03/2012
369142

Return
Front Panels may stop updating with 3+ monitors with Windows Aero enabled
With Windows Aero enabled on a machine with 3 or more monitors the front panel may stop drawing. This issue has been seen in limited cases and is usually after hours of operation. The application itself continues to run. Moving or minimizing the window causes it to start updating again.

Workaround: Disable Windows Aero by selecting a non-Aero theme.

Reported Version: 2010 SP1  Resolved Version: N/A  Added: 09/01/2012
377385

Return
Error 1390 on Dynamic VI Call to Friend Library
The error is returned when two Community scoped LabVIEW Libraries are Friends to each other, and one Library performs a dynamic call to a VI in the other Library.

Workaround: Change the dynamic call to a static call, or change the scope to Public on the Library containing the callee VI.

Reported Version: 2012  Resolved Version: N/A  Added: 01/28/2013
364845

Return
Streaming data to a Digital Display Chart data occasionally incorrectly displays zero even when the data is non-zero
N/A

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 01/29/2013
367249

Return
It is not possible to customize the Run-Time Shortcut menu of a 3D Graph
N/A

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 01/29/2013
381656

Return
Adding or subtracting timestamps causes a conversion to double and precision loss
N/A

Workaround: Cast the timestamps to clusters of U64 'seconds since epoch' and I64 'fractions of a second' before the operation and then cast back to timestamp after the operation

Reported Version: 2011  Resolved Version: N/A  Added: 01/29/2013
257735

Return
Class VIs that call shared variables in a library in an auto-populating folder will not be loaded
If a VI in a class calls a shared variable that is in a library in an auto-populating folder, it will not find the shared variable when the project is loaded

Workaround: Make the folder a snapshot instead of auto-populating and reopen the project

Reported Version: 8.6.1  Resolved Version: N/A  Added: 02/01/2013
381128

Return
The MonthCalendar .NET control automatically resizes to the incorrect size when the VI is run
N/A

Workaround: At the beginning of the code write to the Container Bounds property node "ContBounds" for the .NET container. While the code is running the calendar will have the right size

Reported Version: 2012  Resolved Version: N/A  Added: 02/01/2013
305978

Return
Save As Duplicate with Include All Dependencies makes a Copy of the instr.lib Folder.
Include All Dependencies option in Save As does not ignore files from laview\instr.lib folder.

Workaround: Choose "Select contents to copy" and uncheck instr.lib

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 08/02/2013
388446

Return
Eval Parsed Formula Node.vi returns incorrect results
Incorrect results are possible if preceding Parse Formula Node.vi contains too many C-style comments.

Workaround: Reduce the amount of comments used in formula input to Parse Formula Node.vi

Reported Version: 2012  Resolved Version: N/A  Added: 08/02/2013
389041

Return
Error -314250 from Create Network Stream Writer Endpoint
Error is returned when data type is set with a SGL value that has a unit label defined.

Workaround: Change representation or DBL, or remove the unit label.

Reported Version: 2013  Resolved Version: N/A  Added: 08/02/2013
391455

Return
Applying an icon to LabVIEW class overwrites the icons of its methods
The icon for a LabVIEW class appears to be only the banner, but when it is applied it overwrites the entire icon of the method VIs

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 08/02/2013
391784

Return
Memory Lead when Sound VIs are Called Dynamically
Sound Input Configure.vi and Sound Input Clear.vi leak memory when called dynamically

Workaround: Use a static call to these VIs.

Reported Version: 2012  Resolved Version: N/A  Added: 08/02/2013
392545

Return
Timed Loop crashes LabVIEW after exiting
A timed loop that meets these criteria can crash LabVIEW after finishing execution.
1) The Timed Loop must write to the "Offset" input node inside the loop
2) The Timed Loop must have set the "Mode" input node to anything else other than "No Change" or "Discard missed periods, ignore original phase" before the loop begins

Workaround: Configure the Timed Loop once at the beginning of execution instead of each iteration.

Reported Version: 2012  Resolved Version: N/A  Added: 08/02/2013
394454

Return
Data Binding: Path property can change bindings in other VI clones
Writing to a Data Binding: Path can change binding path for other instances of the control if clones of the VI are already open

Workaround: Use programmatic Shared Variable access to update front panel controls instead of Data Binding.

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 08/02/2013
398998

Return
3D Surface Axis Labes not Visible when Dialog Font Changed
Some fonts cause the Axis Labels to be visible on 3D Surface controls when the Dialog Font is changed from default. For example MS Sans Serif causes the issue.

Workaround: Use a Dialog font that doesn't cause the issue.

Reported Version: 2012  Resolved Version: N/A  Added: 08/02/2013
399068

Return
Double Numeric Slide can not be Set to 0 when it has Defined Limits with Mouse
A user can not slide a Double Numeric Slide to 0 when it has defined increment, maximum, and minimum properties. Instead of 0, a value very close to 0 will be entered ie: 5.55112E-16.

Workaround: Do not set both defined maximum and minimum for the slide. Instead, change one of them to Inf or -Inf. Also a value of 0 can be entered into the digital slide.

Reported Version: 2012  Resolved Version: N/A  Added: 08/02/2013
401421

Return
Updates to Global Variables Not Visible when Remote Debugging a LabVIEW Built Stand-Alone Application
If the updates occured before connecting to the Remote Application with the debugger, the updates won't be visible. Updates to the Global Variable after connection with the debugger is establish will be visible.

Workaround: Change the build specification for the stand-alone application to wait for debugger on launch, so no Global Variable updates can happen until a debug session is started.

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 08/02/2013
403182

Return
Sound Output.vi Does Not Support more than 2 Audio Channels on Windows 7
Error 4811: "can not support sound format" will be returned from the VI when executed on Windows 7.

Workaround: More than 2 Channels are supported on Windows XP.

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 08/02/2013
403727

Return
Repeated Dynamic Calls to VI in Packed Project Library Can Cause Error in VI Call
After over a million Dynamic Calls to a VI contained in a Packed Project Library, a error can be thrown that LabVIEW attempted a recursive call.

Workaround: The error does not occur on regular project libraries.

Reported Version: 2011 SP1  Resolved Version: N/A  Added: 08/02/2013
405271

Return
Boolean Mechanical Actions Don't Work as Expected on Windows 8 Touch Screen
Switch Until Released and Latch Until Released don't behave as expected for touch and hold gesture. Boolean controls will not toggle on touch and hold gesture, until finger is dragged outside the bounds of the control. Other Boolean mechanical actions behave as expected.

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 08/02/2013
406311

Return
VI.Control Value.Set will Crash LabVIEW When Value Non-Variant Data is Used for Value Parameter
The crash will happen when VI.Control Value.Set is invoked upon a VI reference that has been opened by Open VI Reference.

Workaround: Cast data to variant before wiring to Value parameter.

Reported Version: 2012  Resolved Version: N/A  Added: 08/02/2013
407614

Return
Control.Delete Method Crashes LabVIEW When Used on Grouped Pictures and Free Labels
LabVIEW will crash when VI scripting method Control.Delete is invoked on pictures or Free Labels that are grouped on the front panel.

Workaround: N/A

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 08/02/2013
407633

Return
Set Cell Value Method Returns Error 1604
Set Cell Value method for tables returns error 1604 if method executes at the same time that a user changes the value of a Picture Ring Control.

Workaround: Architect code so table is not updating continuously to reduce risk that user changes Picture Ring value at the same time that Set Cell Value is executing.

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 08/02/2013
408391

Return
Non-printable Characters in the Description of Will Corrupt LabVIEW Classes and Libraries
Non-printable characters can be inserted into the description of LabVIEW Classes and Libraries with the Description Property Node. This will corrupt the .lvclass or .lvlib file.

Workaround: The .lvclass or .lvlib file can be opened in a text editor, and the description can be manually deleted to recover the files.

Reported Version: 2012  Resolved Version: N/A  Added: 08/02/2013
408790

Return
Palette Editor Cannot Add LabVIEW Classes
LabVIEW Classes are an available option to be added to palettes, but adding them will not take effect.

Workaround: If your goal is to allow dropping of the class control or constant, you can create a custom control (not a typedef) that has the class on it's panel and add the custom control to the palettes. If your goal is to add the LabVIEW Class as a linked library, you can do so programmatically with Write Palette.vi.

Reported Version: 2009  Resolved Version: N/A  Added: 08/02/2013
410360

Return
LabVIEW Classes Become Corrupt When Multiple Files With Same File Name are Added to the Class
When a LabVIEW Class is saved with multiple files sub-files that have the same file name, the .lvclass file will become corrupt.

Workaround: N/A

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 08/02/2013
410479

Return
Grouping ActiveX containers removes inserted ActiveX objects
When populated ActiveX containers are grouped with other front panel objects, the inserted ActiveX object will be removed.

Workaround: Re-insert the ActiveX object after it has been grouped with another object, or group a blank ActiveX container, then insert the object.

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 08/02/2013
410904

Return
Print.VI to Printer Method Always Prints Header in LabVIEW Built Applications
The Page Headers? parameter for Print.VI to Printer is always true when running as a LabVIEW Built Application. The parameter is used properly when the method is ran in the LabVIEW development environment.

Workaround: 1. Select Operate»Print at Completion to print the front panel of a VI when it finishes running.
2. Select File»VI Properties.
3. Select Print Options from the Category pull-down menu.
4. Place a checkmark in the Automatically Print Panel Every Time VI Completes Execution checkbox.
5. Uncheck Print header (name,date,page number) box
6. Click the OK button.

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 08/02/2013
415924

Return
Double precision numeric constants set to "bar" units sometimes use Pa units
Double precision numeric controls and indicators using "bar" units work correctly, but block diagram constants use Pa instead of bar.

Workaround: Create the constant from a control with "bar" units and then change the unit label from Pa to bar to get a constant that uses bar.

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 10/14/2013
420965

Return
Adding a tooltip for a tab control after configuring the tab to show text and image can cause the tooltip to appear in the wrong position
If you configure a tab control for text-image content, and then add an image and change the tooltip, the tooltip will appear far away from the tab control.

Workaround: View the tooltip after adding the image and before changing the default tooltip

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 10/14/2013
408891

Return
Getting an Entire Column of Data from a 2D Array in the MATLAB® Script Node Returns Only 1 Element
In the context of the MATLAB® Script Node, attempting to return an entire column of data from an array using a command like "column1 = array2D(:,1);" returns only a single element. This same operation on a row "row1 = array2D(1,:);" , returns the entire row successfully.

Workaround: Transpose the array, and get the data in it's context as a row.

Reported Version: 2012  Resolved Version: N/A  Added: 10/16/2013
412979

Return
Flatten to XML String does not properly escape single and double apostrophes in a string input (' and ")
These should be escaped to "apos" and "quot" but are not. Other special characters including &,<, and > are correctly escaped.

Workaround: Parse the string manually for apostrophes to escape them

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 10/17/2013
422507

Return
Entering an integer into a numeric control that has a time display format does not update the control
Double clicking inside a time display numeric control and typing a new value does not update to the new value, and the control reverts to its original value. This happens for controls with a display format of either %t or the default Relative Time format.

Workaround: If the display format is %t, enter values with a decimal point after the number (as a double)
If the display format is the default Relative Time, single click on the hour or minute fields and update individually or enter the value in the format HH:MM with the colon to successfully update

Reported Version: 2013  Resolved Version: N/A  Added: 10/23/2013
428515

Return
On Scientific Linux 6.3 with updated Mesa Drivers, 3D Picture Controls display an inverted image
N/A

Workaround: Downgrade the Mesa drivers or manually invert the image.

If your 3rd-Party Mesa driver version is between 7.11 and 9.2.1, you need to add the LabVIEW INI token "Invert3DPictImage=True". Driver version 7.11 and earlier, and version 9.2.1 and later, do not need the INI token.

Reported Version: 2013  Resolved Version: N/A  Added: 10/23/2013
390021

Return
An inlined VI can not be placed on the block diagram of a VI with subroutine priority unless it also has subroutine priority
Inlined VIs should ignore the Priority setting in VI properties, however an inlined VI dropped in a subroutine priority VI will break the run arrow unless the inlined VI is also set to subroutine priority.

Workaround: Set the inlined subVI to subroutine priority

Reported Version: 2012  Resolved Version: N/A  Added: 03/11/2014
425313

Return
Selecting the option to hide grid lines when using Export Simplified Image with a waveform graph will not hide all grid lines when using multiple axis
When using the waveform graph right-click option to Export Simplified Image with the option to hide grid lines, some of the grid lines will still be visible if there are multiple axis

Workaround: Disable the grid of the additional axis through the scale tab of the graph properties

Reported Version: 2013  Resolved Version: N/A  Added: 03/11/2014
430758

Return
It is not possible to save a VI with the name of another VI in memory, even if they are in different libraries
LabVIEW does not check the library namespace when determining if a VI is being saved with a name that is already in use. If a VI is in memory, it is not possible to save another VI with the same name in the same project even if they are in different libraries.

Workaround: Close the other VIs with the same name so they are not in memory.

Reported Version: 2013  Resolved Version: N/A  Added: 03/14/2014
432182

Return
Custom labels on a 3D bar chart do not display properly in a 2D view
Custom labels on a 3D bar chart will revert to a numeric value when viewed in a 2D Projection

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 03/14/2014
437390

Return
File Path control does not display "Browse" dialog if Start Path is an invalid network path.
LabVIEW may hang while waiting for Windows to locate an invalid network directory. The control's owning VI may hang while it searches for the directory, or it may appear that the "Browse" button does not have any affect and does not invoke a dialog. This can happen if the Start Path input in Browse Options... is an invalid path or if the Start Path in blank and the control's value is invalid.

Workaround: Make sure the Start Path input is valid before selecting the Browse button. If the Start Path input is blank, change the File Path control's value to a known valid path before browsing.

Reported Version: 2012  Resolved Version: N/A  Added: 03/24/2014
428914

Return
The Y-Axis of a Mixed Signal Graph will not correctly scale when the graph is set to "Scale Object with Pane" and the user decreases the size of the VI Front Panel.
Increasing the size of the pane will result in the graph growing and scaling its axes correctly, but decreasing the size of the pane will only shrink the graph without scaling the Y-Axis. The Y-Axis will now have a scroll bar due to not scaling.

Workaround: Use the "Plot Area" Property Node to shrink the graph to appropriate size.

Reported Version: 2013  Resolved Version: N/A  Added: 03/31/2014
433596

Return
The 3D Surface Plot does not draw correctly when the input data is an array of the same value
The plot is completely blank if the array contains only the same value. Changing one value correctly draws the 3D Surface Plot

Workaround: Manually or programmatically toggle the Z-Axis range, or turn off Auto Scaling on Z-Axis, and the plot will appear

Reported Version: 2013  Resolved Version: N/A  Added: 03/31/2014
458973

Return
Writing a negative number to single point float Network Shared Variables through the OPC I/O Server fails.
N/A

Workaround: Use Double precision shared variables instead.

Reported Version: 2013  Resolved Version: N/A  Added: 03/31/2014
469268

Return
Formula Node and MathScript Node variable labels can shift to become misalligned
After opening and closing its VI, the label will no longer look centered inside its owning box

Workaround: This should not affect functionality. Recreate the variable on the node's border to recenter the label

Reported Version: 2013 SP1  Resolved Version: N/A  Added: 05/02/2014
461969

Return
When using a class containing a DAQmx Physical Channel control, it will not properly load that information from an XML file.
The control can be changed and saved to the XML as expected and seen when opening the XML. However, when you try to load the channel from the XML it appears blank.

Workaround: If you place the class cluster in an additional cluster the DAQmx Physical Channel control saves and loads as expected.

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
468139

Return
.NET Callback Event VI keeps the Callback VI reserved even after calling a Close Reference VI is called
For example, when running the "Passing data to a .NET Event Callback.vi" example, after stopping the main example VI, the "Callback - EventHappened.vi" is still reserved.

Workaround: Call GC.Collect() from an invoke node after closing the Callback VI's reference or in a separate VI to un-reserve the callback VI. This workaround does not work in LabVIEW 2018.

Reported Version: 2013 SP1  Resolved Version: N/A  Added: 05/07/2014
384591

Return
A password protected VI accessing a password protected community scoped VI is broken if the VIs are set to separate compiled code from source code
This only happens if the VI source-only option set to true: Tools -> Options -> Environment Settings -> Separate Compiled Code from New Files set to true, or via the VI Properties window

Workaround: Do not separate the compiled code from the source code or remove the password

Reported Version: 2011 SP1  Resolved Version: N/A  Added: 05/09/2014
478232

Return
In certain cases, LabVIEW may incorrectly crisscross wires during loop creation
When adding a loop around existing code, LabVIEW may reconnect wires to the incorrect tunnels on the border of the loop

Workaround: Manually reconnect the appropriate wires and tunnels

Reported Version: 2014  Resolved Version: N/A  Added: 06/19/2014
470218

Return
LabVIEW (64-bit) for Mac, does not show the login prompt for Revision History when starting LabVIEW
In Tools>>Options, you can set the "User Name to Record in VI Revision History" to "LabVIEW registration name" which adds the token "history.whereToGetName=LabVIEW" to the LabVIEW.ini or LabVIEW.app file, for Windows and Mac OS X respectively. Changing the token to "history.whereToGetName=prompt" should invoke a login dialog each time LabVIEW starts, but the dialog does not appear in LabVIEW (64-bit) for Mac.

Workaround: After LabVIEW finishes launching, select Tools>>User Name to view the login dialog.

Reported Version: 2014  Resolved Version: N/A  Added: 07/28/2014
420582

Return
Typing Obtain in Quick Drop populates with an unexpected selection
N/A

Workaround: Disable 'relevancy-based search' in the Quick Drop configuration options

Reported Version: 2013  Resolved Version: N/A  Added: 07/31/2014
IDKnown Issue
442745

Return
RF-RIO Instr Default Personality 5646R.lvproj's FPGA VI will hang on save.
Instrument driver\RFSA\5645R\Public\Apply Digital Correction.vi located in RF-RIO Instr Default Personality 5646R.lvproj will hang on save. This happens when removing the diagram disable structure. In addition, the VI cannot compile.

Workaround: Currently, using the structure wrap included in the example code is recommended. If you only use one instance of the polymorphic VI, re-arrange the instances such that the instance you wish to use appears first in the list.

Reported Version: 2013  Resolved Version: N/A  Added: 07/31/2014
462021

Return
In LabVIEW for Mac, filtered menu tracking is not cancelled until the event's case finishes executing
If you are the filter event "Menu Activation?" and you discard the event, the menu activation will not be cancelled until that case in the event structure finishes executing. This may cause the menu to appear momentarily before it disappears.

Workaround: Programmatically hide or disable the menu instead of filtering an event for it.

Reported Version: 2014  Resolved Version: N/A  Added: 07/31/2014
480386

Return
ActiveX call to open PDF (Adobe Reader 11.0.07) results in LabVIEW crashing
More information at https://forums.adobe.com/message/6396203#6396203

Workaround: Downgrade to an earlier versions of Adobe Reader (11.0.6 and earlier)

Reported Version: 2013  Resolved Version: N/A  Added: 07/31/2014
401078

Return
Opening any non-VI dialog, such browse for files or one button dialog, may block web service requests from executing.
The most common form of this issue seen when Show Method URL Dialog Box blocks requests to a LabVIEW Web Service. This only affects LabVIEW web services deployed to the debug server or embedded in a LabVIEW executable.

Workaround: Close the dialog box to allow requests to continue

Reported Version: 2013  Resolved Version: N/A  Added: 12/01/2014
467735

Return
"Format into File" produces Error 1 when appending to a file that has a size of 4 GB
See this NI Community page for more information.

Workaround: Use "Format Into String" and "Write to Binary File".

Reported Version: 2013  Resolved Version: N/A  Added: 12/01/2014
492341

Return
LabVIEW TDMS Advanced Asynchronous Write does not return error when target disk is full.
N/A

Workaround: Use the TDMS Reserve File Size Function to allocate disk space before writing

Reported Version: 2014  Resolved Version: N/A  Added: 12/01/2014
485336

Return
Deleting a second y-axis on a waveform graph with a cursor crashes LabVIEW
When using a waveform graph indicator, it is possible to crash LabVIEW with an access violation error 0xC0000005 at EIP=0x00FE9E79 by creating two y-axis scales, creating a graph cursor, changing the cursor's associated y-axis, and then deleting the original y-axis scale.

Workaround: Remove the scale from the waveform graph, remove the unwanted y-axis scale, then recreate the cursor.

Reported Version: 2013 SP1  Resolved Version: N/A  Added: 06/17/2015
493624

Return
Change of .NET assembly version requires manual relink of static class methods/properties
A version change to a .NET assembly (the only change) breaks the reference connection of methods/properties of static classes. When starting LV with the new assembly version, the version change warning is shown but the run arrow is broken. A manual relink of the properties/methods is required.

Workaround: N/A

Reported Version: 2013 SP1  Resolved Version: N/A  Added: 06/17/2015
493662

Return
.NET Constructor Node cannot differentiate between functions with different enums at the same position
N/A

Workaround: Create a wrapper assembly to call from LabVIEW

Reported Version: 2014  Resolved Version: N/A  Added: 06/17/2015
507856

Return
Replacing an Intensity Graph with z-axis autoscaling enabled with a Waveform Graph or XY Graph causes LabVIEW to crash
N/A

Workaround: Delete the Intensity Graph and add a Waveform Graph or XY Graph rather than using the replace option.

Reported Version: 2014  Resolved Version: N/A  Added: 06/17/2015
510218

Return
Create Mask.vi does not work in conjunction with the Get Image Subset.vi in LabVIEW
N/A

Workaround: Swap the Dimension Size inputs of the Reshape Array in the Case Structure at the bottom of Get Image Subset.vi.

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 06/17/2015
515300

Return
NamedBundler function in LV Scripting does not work properly when the reference is opened from a New VI function
N/A

Workaround: Use the Open VI Reference and Save A Copy functions, rather than New VI function, to create a new instance of a vi from a template.

Reported Version: 2014  Resolved Version: N/A  Added: 06/17/2015
584837

Return
Mass compiling a project from project explorer in certain cases can cause LabVIEW to hang.
Mass compiling a project from project explorer with an unsaved VI can cause LabVIEW to hang.

Workaround: N/A

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 04/29/2016
570754

Return
Linear Fit produces NaN result if X input value is too large
Linear Fit produces NaN result if X input value is too large. Values above around 2.2x10^9 in LabVIEW 32 bit or 4.9x10^7 in LabVIEW 64 bit may exhibit this behavior.

Workaround: Modify your data to smaller absolute values before using this function.

Reported Version: 2015  Resolved Version: N/A  Added: 06/10/2016
457854

Return
Aborting a VI can leave VIs targeted by a Call By Reference node reserved permanently
N/A

Workaround: Close the project to unreserve the VI

Reported Version: 2013  Resolved Version: N/A  Added: 08/08/2016
504716

Return
Advanced Asynchronous Write function does not return an error when target disk is full or removed
N/A

Workaround: Use the TDMS Reserve File Size Function to allocate disk space before writing

Reported Version: 2014  Resolved Version: N/A  Added: 08/08/2016
509876

Return
Bundle by Name function can send wrong pointer into subVI with Call Library Function Node
If a main VI has the output of a Bundle by Name function connected to a subVI, a Call Library Function node within the subVI can receive the wrong pointer from the wired cluster.

Workaround: Remove the Bundle by Name function or the subVI
OR
Replace the control input to the Bundle by Name function with a constant

Reported Version: 2013 SP1  Resolved Version: 2019 SP1  Added: 08/08/2016
521856

Return
Rare LabVIEW crash when using "Panel Close?" filtering event and "Quit LabVIEW" function
N/A

Workaround: Either do not use the "Panel Close?" event, do not open the front panel of the VI being closed, or turn off scrollbar visibility using a property node.

Reported Version: 2014 SP1  Resolved Version: N/A  Added: 08/08/2016
529278

Return
MATLAB Script Node can output different data in LabVIEW 32-bit vs. 64-bit
N/A

Workaround: Use LabVIEW 32-bit for MATLAB Script Nodes

Reported Version: 2014 SP1  Resolved Version: N/A  Added: 08/08/2016
544257

Return
Inplace issue can occur when using LabVIEW 32-bit on a 64-bit operating system.
Running a VI that calls a subVI containing a Call Library Function Node to the kernel32.dll IsWow64Process can cause the returned value of the dll to be incorrect.

Workaround: Adding an "Always Copy" dot before the control that is wired to the Front Panel Terminal within the subVI fixes the issue.

Reported Version: 2014  Resolved Version: N/A  Added: 08/08/2016
544623

Return
LabVIEW 64-bit for Mac OS can improperly create special characters.
LabVIEW 64-bit for Mac OS improperly creates special characters such as the 'degree' symbol and 'micro' symbol that cannot be read correctly.

Workaround: Avoid using special characters.

Reported Version: 2015  Resolved Version: N/A  Added: 08/08/2016
552304

Return
SMTP Client VI Example incorrectly converts some characters when placed in subject line
Email sent using the SMTP Client VI shipping example converts "!", ":", and "~" to "?" in the subject line of emails.

Workaround: N/A

Reported Version: 2013 SP1  Resolved Version: N/A  Added: 08/08/2016
558774

Return
Constructor node for FolderDialogBox from Windows.System.Forms (4.0.0) causes hang during execution
In recent versions of LabVIEW, placing a constructor for a FolderDialogBox object from Windows.System.Forms (4.0.0) will work successfully, but the containing VI will hang during execution.

Workaround: Do not use FolderDialogBox objects.

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 08/08/2016
558891

Return
In some scenarios, LabVIEW Menu positions within a VI or project are offset in Windows 10
For multiple displays, Windows 10 allows you to set different "size for text and other items" (magnification) for each display. In the case you have different magnifications between displays, the drop down menus of a VI or project are offset to the right and down. This can be dramatic (even off the screen) when the two magnifications are very different.

Workaround: Use a consistent magnification level for all displays.

Reported Version: 2014 SP1  Resolved Version: N/A  Added: 08/08/2016
565884

Return
When creating .NET assemblies in LabVIEW, 1-dimension arrays of doubles or strings are represented as 2-dimension arrays of rank 1
When creating .NET assemblies in LabVIEW, 1-dimension arrays of doubles or strings are represented as 2-dimension arrays of rank 1. This can create an issue when the assembly is used in Visual Studio 2015 which will not accept 2-dimensional arrays of rank 1.

Workaround: Pass a 2D array in LabVIEW instead of a 1D array.

Reported Version: 2013 SP1  Resolved Version: N/A  Added: 08/08/2016
570102

Return
Calling the "Web Server: Server Active" property causes a small memory leak.
Calling the "Web Server: Server Active" property on any supported platform (including RT) creates a small memory leak.

Workaround: Restart the application to allow the OS to reclaim the memory, or do not call this property often.

Reported Version: 2014  Resolved Version: N/A  Added: 08/08/2016
571353

Return
XNode can cause Dirty Dot when no parameters are modified
When abilities of XNodes are called, LabVIEW can erroneously report that changes have been made to the VI and prompt the user to save.

Workaround: N/A

Reported Version: 2015  Resolved Version: N/A  Added: 08/08/2016
574329

Return
Error 4 thrown in executable but not in development environment
Sometimes after manipulating the format specifier on the Open/Create/Replace primitive and then saving and reopening the VI, the VI can throw Error 4: End of File encountered on the next run. This may also occur when the application is run as an executable.

Workaround: N/A

Reported Version: 2015  Resolved Version: N/A  Added: 08/08/2016
576990

Return
Assembly created by Web Service Importer from WSDL throws error 1172
In certain cases, it is possible for the Web Service Importer tool in LabVIEW to throw error 1172 when trying to import a WSDL schema.

Workaround: Remove complex data types from the WSDL file.

Reported Version: 2015  Resolved Version: N/A  Added: 08/08/2016
578085

Return
Saving a very large VI in LabVIEW 2015 and later can take longer than in previous versions
When compared to save times in earlier versions of LabVIEW, saving a large VI in LabVIEW 2015 and later takes a longer amount of time to complete.

Workaround: Try the steps listed in this KB to minimize save time: http://ae.natinst.com/public.nsf/web/searchinternal/e43b32c14030c3b686256c1e0044d9b6?OpenDocument

Reported Version: 2015  Resolved Version: N/A  Added: 08/08/2016
583670

Return
If LabVIEW 2016 is installed, installers built in any version of LabVIEW will not work on Windows 7 RTM and older
See the following KB for details: http://digital.ni.com/public.nsf/allkb/93EC6C4911C6B72E86257FAA0067CC79?OpenDocument

Workaround: Do not install LabVIEW 2016 on a computer which builds installers for Windows 7 RTM, Windows Vista, Windows XP SP3, and older.

Reported Version: 2015 SP1  Resolved Version: N/A  Added: 08/08/2016
584455

Return
Certain Silver Controls appear differently on Front Panel versus Print Output
When using the File >> Print option to print a Front Panel containing a Silver Boolean Control or Silver Meter Indicator, the printed version might not match up with the real values or style.

Workaround: Use other style controls

Reported Version: 2016  Resolved Version: N/A  Added: 08/08/2016
585867

Return
LabVIEW 64-bit can crash while closing a VI containing certain ActiveX containers
Certain ActiveX containers such as Microsoft InkEdit Controls can cause complications when they are unloaded from memory in LabVIEW 64-bit, such as when the containing VI is closed.

Workaround: N/A

Reported Version: 2015  Resolved Version: N/A  Added: 08/08/2016
634531

Return
Template methods in a C++ DLL do not appear in the Function Name drop down list of the Call Library Function Node.
Some C++ DLLs include methods which are created from a template during compilation. These template methods will not appear in the list of function names when using the Call Library Function Node.

Workaround: 1. Create wrapper functions that call the template methods, then call the wrapper functions using the Call Library Function Node.
2. Manually specify the function prototype in the function name field of the Call Library Function Node.

Reported Version: 2015 SP1  Resolved Version: N/A  Added: 04/18/2017
317117

Return
3D Surface Graph incorrectly blends colors when interpolating
In certain situations when viewing a projection onto a 2D plane, the 3D Surface Graph can incorrectly blend colors instead of displaying them in a straight line.

Workaround: N/A

Reported Version: 2011 32-bit  Resolved Version: N/A  Added: 05/22/2017
432523

Return
Reordering elements of a cluster within the private data of a class can break VIs that reference the class
If you have a cluster within the private data of a class and you reorder the elements of the cluster, VIs that reference the class can become broken.

Workaround: Close and reopen the LabVIEW project after reordering the cluster

Reported Version: 2013  Resolved Version: N/A  Added: 05/22/2017
590224

Return
In some cases, using an XControl in a PPL can cause LabVIEW to hang
If you build an XControl into a PPL and include the XControl on the front panel of a VI that is also built into the PPL, the VI can hang in some cases.

Workaround: N/A

Reported Version: 2015 SP1  Resolved Version: N/A  Added: 05/22/2017
596788

Return
The struct ErrorCluster from InteropAssembly throws case sensitivity error in Visual Basic
The user gets the following error when using the struct ErrorCluster in Visual Basic: "'Status' is ambiguous because multiple kinds of members with this names exist in structure 'ErrorCluster'".
The struct NationalInstruments.LabVIEW.Interop.ErrorCluster defined in the DLL NationalInstruments.LabVIEW.Interop.dll has the following variable definition:
Public code As Integer
Public source As String
Public status As Boolean
Public Sub New(statusIn As Boolean, errorCode As Integer, errorMessage As String)
Public ReadOnly Property Code As Integer
Public ReadOnly Property Source As String
Public ReadOnly Property Status As Boolean

The first three members have the same name of the last three aside from the capitalization of the first letter. Although MSIL is case-sensitive, VB is case-insensitive, which is therefore causing the error.

Workaround: 1. Use the generic .NET Exception, which will have the same information as the ErrorCluster.
2. Build a wrapper in C#, then use that in VB.NET

Reported Version: 2015 SP1  Resolved Version: N/A  Added: 05/22/2017
599746

Return
When building a web service into an EXE and making an installer, some software dependencies are not automatically selected as additional installers
If you build a web service into an EXE that has method VIs with software dependencies, such as the use of a hardware driver, only VIs with dependencies that are included as Startup VIs for the web service will be automatically selected as additional installers. Any method VI that is not a Startup VI will not have its software dependencies automatically selected.

Workaround: Build the web service into the installer rather than the EXE or manually include the required software dependencies

Reported Version: 2015 SP1  Resolved Version: N/A  Added: 05/22/2017
602529

Return
Open/Create/Replace File does not return an error when attempting to create a file name that is restricted by the OS
When attempting to create a file with the Open/Create/Replace File primitive, the file will not be created but LabVIEW will not return an error. Examples of file names that are restricted by the OS are COM8.txt, LPT4.txt, etc.

Workaround: N/A

Reported Version: 2010 SP1  Resolved Version: N/A  Added: 05/22/2017
603204

Return
When using a cylindrical coordinate system on a 3D scatter plot, the color ramp legend does not reflect the displayed color gradient
After changing the coordinate system to cylindrical, the graph will correctly display the color gradient according to distance from the origin. However, the legend will display the color ramp based on the minimum and maximum values of the z axis.

Workaround: N/A

Reported Version: 2015 SP1  Resolved Version: N/A  Added: 05/22/2017
606191

Return
Building a .NET Interop Assembly with an array of classes as an output fails
When an exported VI has an array of classes as an output, attempting to build the .NET Interop Assembly results in error 1172.

Workaround: Extract the data from the classes then bundle and output the data as an array of clusters

Reported Version: 2015 SP1  Resolved Version: N/A  Added: 05/22/2017
607058

Return
Flattening an EXT representation numeric to JSON causes loss of precision
N/A

Workaround: Use Format Into String followed by Flatten to JSON

Reported Version: 2013 SP1  Resolved Version: N/A  Added: 05/22/2017
607411

Return
When using a LabVIEW-built .NET Interop Assembly in an ASP .NET application, the first call to the assembly will return a NullReferenceException
N/A

Workaround: The exception only occurs on the first call to the assembly, so using a try-catch block to handle the exception will allow subsequent calls to behave normally.

Reported Version: 2015 SP1  Resolved Version: N/A  Added: 05/22/2017
613423

Return
Registering for an event for multiple boolean controls can fail in specific configurations
When passing a mixture of strict and non-strict boolean references in a cluster to the event source terminal of the Register For Events node, the input wire will break if any strict references are not the first elements of the cluster.

Workaround: Use a Switch mechanical action, group the references with Build Array, or place any strict references at the beginning of the cluster.

Reported Version: 2016  Resolved Version: N/A  Added: 05/22/2017
IDKnown Issue
614154

Return
Renaming a shared variable with a special character in its name (ö/ü/ä/ß) fails when the project is reopened
If you attempt to rename a shared variable that has a special characters in its name, the name will revert to the original name when the project is reopened

Workaround: Do not use special characters in shared variable names

Reported Version: 2016  Resolved Version: N/A  Added: 05/22/2017
616849

Return
LabVIEW files are saved without an extension after attempting to save with an invalid character
If you attempt to save a LabVIEW file with an invalid character (such as ?), the file is correctly not saved. However, if you remove the invalid character and save the file, it will be saved with no extension on disk.

Workaround: After saving, add the correct extension to the file

Reported Version: 2010 SP1  Resolved Version: N/A  Added: 05/22/2017
617826

Return
LabVIEW will not generate a Key Down event if the mouse is held down on a cell inside a table control
If you hold the left mouse button down on a cell inside of a table control, LabVIEW will not generate a Key Down event on the first key press. Subsequent key presses will generate the event as normal

Workaround: N/A

Reported Version: 2015 SP1  Resolved Version: N/A  Added: 05/22/2017
618568

Return
Reference leaks with the Audio DataPlugin
Calling the Write Data [Channel] Express VI with the Audio DataPlugin in a loop causes LabVIEW to leak references, causing memory growth over time

Workaround: N/A

Reported Version: 2016  Resolved Version: N/A  Added: 05/22/2017
624802

Return
Setting binding properties of a control within a preallocated clone subVI or XControl sets the property for all instances of the subVI or XControl
If the BindingPath property is set on a control within a preallocated clone subVI or XControl, all instances of the controls in the subVI or XControl update their BindingPath rather than the one where the property was set

Workaround: Create a unique SubVI or XControl for each instance

Reported Version: 2016  Resolved Version: N/A  Added: 05/22/2017
625718

Return
The Web Publishing Tool has incompatibility issues with Internet Explorer 11
When the Web Publishing Tool tries to create a pop-up dialog box or a window, the pop-up dialog box or window will be blocked, and Internet Explorer hosting the Web Publishing Tool may hang or crash. This issue was detected in Internet Explorer 11.

Workaround: On Internet Explorer 11, select Internet options from the Tools menu, switch to the Security tab, remove the checkmark from Enable Protected Mode, and restart Internet Explorer.

Reported Version: 2017  Resolved Version: N/A  Added: 05/22/2017
627783

Return
Using TCP Open Connection with a Timeout of 0 can cause connection failures
When you specify a Timeout of 0 for TCP Open Connection, it will return error 56. However, in some cases, a connection can still be established. This will cause subsequent connection attempts to fail, even when they have a nonzero timeout.

Workaround: Always use nonzero timeouts

Reported Version: 2010 SP1  Resolved Version: N/A  Added: 05/22/2017
629032

Return
Wiring a 2D array with an empty string to the property names input of the TDMS Set Properties function causes data for that channel to be unreadable
If a 2D array with an empty string is wired to the property names input of the TDMS Set Properties function, the TDMS Read function is unable to retrieve data from the channel with the empty name. The TDMS Read function will return error 1.

Workaround: Do not include empty strings in the 2D array of property names

Reported Version: 2016  Resolved Version: N/A  Added: 05/22/2017
631762

Return
Using Export data to Excel on a Waveform Chart that contains an empty waveform can cause LabVIEW to crash
N/A

Workaround: Do not plot empty waveforms or add a data point that is out of range that can be manually removed from the Excel sheet

Reported Version: 2016  Resolved Version: N/A  Added: 05/22/2017
633309

Return
Waveform graphs can resize at runtime
For very large floating point numbers in a waveform graph, the control can permanently resize itself in an attempt to fit the large numbers in the axis label

Workaround: Use Automatic or Scientific as the format type for the Y Axis with large floating point numbers

Reported Version: 2017  Resolved Version: N/A  Added: 05/22/2017
634015

Return
Certain operations will not let the System Exec VI return on Windows 10
Certain commands, such as renaming a file, will cause the System Exec VI to indefinitely wait for a response on Windows 10. The IDE will continue to be responsive and the VI may be aborted. This will only occur with "Wait Until Completion" is set to True.

Workaround: Set "Wait Until Completion" parameter to False

Reported Version: 2016  Resolved Version: N/A  Added: 05/22/2017
634287

Return
Incorrect behavior when creating a .NET Interop Assembly with typedefs
When you have multiple different typedefs with identical definitions (i.e, multiple numeric typedefs), only one of them is exported to a .NET typedef.

Workaround: N/A

Reported Version: 2016  Resolved Version: N/A  Added: 05/22/2017
638070

Return
LabVIEW crashes when calling the Children[] Property Node in a VI with reentrancy set to "Shared clone reentrant execution."
N/A

Workaround: Use the Search Variable Container VI instead of the Children[] Property Node. The regular expression and class inputs can help filter the results.

Reported Version: 2015 SP1  Resolved Version: N/A  Added: 05/22/2017
639524

Return
Changing font to Application font can shrink constants inside of structures
In Japanese LabVIEW, changing the font of items on the block diagram from a non-default font to Application Font can cause constants within a structure to shrink

Workaround: Select all items on the block diagram and press Ctrl+1 to set them to Application Font again

Reported Version: 2014 SP1  Resolved Version: N/A  Added: 05/22/2017
640089

Return
DETT reports a reference leak when using the Open Data Storage express VI and Close Data Storage express VI
N/A

Workaround: N/A

Reported Version: 2016  Resolved Version: N/A  Added: 05/22/2017
640243

Return
XY graph pointers do not copy correctly using Copy Data operation
When a graph annotation is displayed on an XY graph and the user copies the data using Data Operations>Copy Data, the image that is pasted does not properly display the pointers.

Workaround: Use a waveform graph instead of an XY graph when possible

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 05/22/2017
633648

Return
LabVIEW crashes when replacing the Actor Framework library with a packed library
Building a packed library from the Actor Framework libraries and selecting "Replace with packed library..." in a project crashes LabVIEW.

Workaround: N/A

Reported Version: 2016  Resolved Version: N/A  Added: 01/23/2018
634261

Return
The Block Diagram.Get Image Scaled method displays subVIs as black rectangles if the image depth is less than 8.

Workaround: Use a depth greater than 8

Reported Version: 2017  Resolved Version: N/A  Added: 01/23/2018
647354

Return
Opening a new shared variable connection can block reading from other connected variables
When attempting to open a shared variable connection that times out, read operations happening in parallel may stall until the time out occurs.

Workaround: N/A

Reported Version: 2015 SP1  Resolved Version: N/A  Added: 01/23/2018
652898

Return
LabVIEW crashes when attempting to open detailed help for an EXE
If the Help path property of a VI points to a PDF file, LabVIEW will crash when trying to open the detailed help of the EXE

Workaround: N/A

Reported Version: 2015 SP1  Resolved Version: N/A  Added: 01/23/2018
655865

Return
The VI Method Save.For Previous fails to maintain the status of the "Separate compiled code from source file" attribute
When you use the Save.For Previous method on a VI with the "Separate compiled code from source file" attribute set to true, the saved VI will have this attribute set to false.

Workaround: Saving for previous through the File menu works as expected

Reported Version: 2016  Resolved Version: N/A  Added: 01/23/2018
674079

Return
Packed Libraries that have debugging enabled and use XNodes load slowly

Workaround: N/A

Reported Version: 2013 SP1  Resolved Version: N/A  Added: 01/23/2018
674968

Return
LabVIEW does not automatically detect the LabWindows/CVI Runtime installer as a required dependency when building an installer from an EXE that requires the LabWindows/CVI Runtime

Workaround: Manually include the LabWindows/CVI Runtime

Reported Version: 2017  Resolved Version: N/A  Added: 01/23/2018
676013

Return
LVMerge returns error 53 when the VI has a dependency on an XControl

Workaround: N/A

Reported Version: 2017  Resolved Version: N/A  Added: 01/23/2018
678334

Return
Changing the keyboard shortcut of the Bookmark Manager to Ctrl+Shift+3 does not launch the Bookmark Manager when the shortcut is pressed.

Workaround: N/A

Reported Version: 2013 SP1  Resolved Version: N/A  Added: 01/23/2018
339230

Return
Newly created typedefs are not automatically added to library
When creating a subVI from a VI contained within a library, the subVI is added to the caller VI's library. When creating a typedef from a control in the same VI, the typedef is not added to the library.

Workaround: Manually add the typedef to the library.

Reported Version: 2010 32-bit  Resolved Version: N/A  Added: 03/05/2018
678964

Return
Nested XControls require recompile when built into Packed Project Libraries
When an XControl contains another XControl as part of its Facade.vi and is built into a Packed Project Library, it will error out and request a recompile. The recompile requires building the Packed Project Library a second time. The error will persist.

Workaround: Either avoid nesting XControls or use their source directly and do not build them into a Packed Project Library

Reported Version: 2015 SP1  Resolved Version: N/A  Added: 03/05/2018
686923

Return
Bring to Front Invoke Node may not bring window to front
Some operating systems will bring the window in front of all LabVIEW windows but not any other windows. If LabVIEW is not the active window at the time of this call, the window may not come on top of other running windows.

Workaround: Use operating specific calls to find the window and bring it in front of all other windows.

Reported Version: 2017  Resolved Version: N/A  Added: 03/05/2018
631422

Return
Regenerate Channel Instances stop responding
In some situations, channel wires can hang LabVIEW when trying to regenerate channel instances. The hang will not end until LabVIEW is forced to close.

Workaround: Open smaller subVIs containing channel wires first allowing the channels to regenerate. Once all of these are complete, open the calling VI. The smaller instances already regenerated their channel instances.

Reported Version: 2017  Resolved Version: N/A  Added: 03/12/2018
670209

Return
Changing XControl state may lock XControl permanently
When changing XControl states in ways that conflict with pre-existing properties, it is possible to lock the state typedef and all of the property VIs. Unless the workaround applies, these VIs become permanently locked and the contained typedefs will be unable to update.

Workaround: Right-click an instance of the state typedef that exists prior to the edit on non-locked VI and choose Review and Update from Typedef. This will fix all of the VIs, even locked VIs.

Reported Version: 2014 SP1  Resolved Version: N/A  Added: 03/12/2018
677020

Return
Channel wires do not automatically update minor changes in core data type (Not A Bug)
Minor changes in non-typedef data types passed to a channel wire do not automatically update the channel wires. As an example, changing the name of a string contained in a cluster will not update the type: creating an indicator from the channel wire's downstream endpoint will still show the original names of the cluster.

This is not a bug. The situation is identical to using a queue, notifier, user event, or any other type-with-subtype that passes through a subVI terminal. If you have a queue of type cluster and you pass that queue into a subVI, then you change the field names of the upstream cluster, LabVIEW does not rewrite the terminal of the subVI. The only types that propagate changes to subVIs are typedefs. The endpoints of channels are subVIs and follow the same rules. LabVIEW does provide ways to request an update to the endpoints (see workaround).

Workaround: Option 1. Right click on the channel endpoint and chose "Adapt To Element Type". This will rescript the endpoint to exactly match the core type. You will need to repeat this on the other endpoint(s) of the channel.

Option 2. Using a typedef or strict typedef as the channel's core type will ensure the types always match. Any changes made to the typedef will be made to the channel.

Reported Version: 2017  Resolved Version: N/A  Added: 03/12/2018
688771

Return
Cannot add CA-signed certificates to LabVIEW Web Services
LabVIEW Web Services only accept certificates created by the LabVIEW API. Valid certificates will not appear as options to add to web services pushing design decisions to use LabVIEW certificates, even when not the best solution..

Workaround: Create a certificate with an identical name of the key for the signed certificate. Install the certificate selecting your root CA certificate. Create a new virtual host with the previously made certificate. Replace the LabVIEW generated private key with your correct private key in certstore.

Reported Version: 2017 SP1  Resolved Version: N/A  Added: 03/12/2018
684847

Return
Nested PPL VIs cannot be found when debugging built executable
PPLs containing VIs from other PPLs can successfully build into an executable. If a debuggable version of the executable is built, LabVIEW will show the VIs as not found. This prevents debugging from seeing the block diagram for the nested VIs. They will continue to run as programmed.

Workaround: N/A

Reported Version: 2016  Resolved Version: N/A  Added: 03/14/2018
706182

Return
Mass Compile causes LabVIEW crash
LabVIEW 2018 64-bit crashes during Mass Compile if Vision VIs are included, but the Vision Development Module is not installed.

Workaround: Install the Vision dependencies that are required.

Reported Version: 2018  Resolved Version: N/A  Added: 08/14/2018
691608

Return
Match Pattern primitive does not find matches if the Input String is empty.
Match Pattern function will return -1 as the offset past match if the input string is empty and the regular expression is ".*"

Workaround: Use the Match Regular Expression function instead.

Reported Version: 2014 SP1  Resolved Version: N/A  Added: 09/10/2018
703331

Return
LabVIEW Built Application will crash at launch if contained in a folder that has any character not supported in the system codepage
If you use a non-native locale, a LabVIEW executable with a folder name that contains Unicode in its path will crash immediately when run.

Workaround: Do not use any characters not supported in the legacy code page in the folder name containing the EXE.

Reported Version: 2014 SP1  Resolved Version: N/A  Added: 09/10/2018
701859

Return
[Linux Red Hat 6.x] libniPythonInterface.so* symlinks are set to absolute paths
libniPythonInterface.so, libniPythonInterface.so.1 , libniPythonInterface.so.1.0.0 are linked in /usr/local/lib64/ with absolute paths instead of relative paths like the other .so files in the folder. This means that if the RTE is moved out of the root directory, then the EXE will not execute correctly.

Workaround: Manually change the link targets for libniPythonInterface.so, libniPythonInterface.so.1, and libniPythonInterface.so.1.0.0 from specific file paths to relative paths. This should allow the RTE to execute in a non-root directory.

Reported Version: 2018  Resolved Version: N/A  Added: 09/14/2018
704478

Return
Adding array manipulation functions between signed and unsigned numeric arrays incorrectly removes coercion dots
When wiring numeric arrays between unsigned and signed integers of the same bitness, introducing an array manipulation such as Transpose 2D array, Reverse 1D array, Array Subset, and Decimate will remove any coercion dots on subsequent indicators. However LabVIEW is still performing an in-place coercion to the data in the indicator.

The data itself is coerced correctly, but the coercion dot is not shown. This can affect the results from VI Analyzer.

Workaround: N/A

Reported Version: 2010 SP1  Resolved Version: N/A  Added: 09/14/2018
706545

Return
Clicking greyed out option of the Scale Legend when using a Waveform Chart causes LabVIEW to crash
If you add a Waveform Chart to the Front Panel (without wiring anything to it on the Block Diagram) and then expand the Legend to include more Plots, set the Waveform Chart to Stacked Plots, make the Scale Legend visible, and then expand the Scale Legend to show more empty or greyed out y-scales, when you try to select any of the buttons on the greyed out portion, LabVIEW will crash.

Workaround: If you wire any 2D array (even an empty 2D array of doubles) to the Waveform Chart before setting the Waveform Chart to Stacked Plots, the crash will not occur.

Reported Version: 2014 SP1  Resolved Version: N/A  Added: 09/14/2018
706578

Return
LabVIEW RTE crashes when calling a VI that calls an ActiveX object
LabVIEW Run-Time Engine crashes when calling into a mass compiled VI that calls into an ActiveX object.

Workaround: Register Utilities\InstrumenSimulation.dll as an ActiveX server before mass compiling the VI.

Reported Version: 2018  Resolved Version: N/A  Added: 05/17/2019
715295

Return
DataSocket Write VI with default timeout can hang before proceeding
When using the DataSocket Write VI with the default 0 second timeout (or wiring in a 0 second timeout), the VI may hang for 10 seconds before completing.

Workaround: Wire in a short timeout of several ms to the DataSocket Write VI.

Reported Version: 2017 SP1  Resolved Version: N/A  Added: 05/17/2019
723354

Return
Remote debugged EXE returns error when attempting to save class changes
After remote debugging an executable that contains a class, clicking Save on the prompt results in an error.

Workaround: 1. Lock the classes you use before compiling an executable
2.Do not do remote debugging
3. Kill the process

Reported Version: 2018  Resolved Version: N/A  Added: 05/17/2019
724157

Return
[Linux] Build Specifications in Shipping examples may not be runnable by double-clicking
Most Linux shipping examples contain Build Specifications that default to a target output of 'main.exe'. This may not be directly runnable by double-clicking on a Linux OS.

Workaround: 1. Change the name of the 'Target destination' in the build specs and remove '.exe'
2. Change name of built executable and remove the '.exe'
3. Run 'Main.exe' via the command line
4. Delete the default build spec and create a new one

Reported Version: 2018 SP1  Resolved Version: N/A  Added: 05/17/2019
727256

Return
LabVIEW doesn't make a local copy of lvanlys.dll when building a PPL
When building a Packed Project Library that includes a VI in the LabVIEW analysis library (lvanlys.dll), a local copy is not made to the output directory.

Workaround: Copy the lvanlys.dll (...National Instruments\LabVIEW 2018\resource) to the PPL output directory.

Reported Version: 2018  Resolved Version: N/A  Added: 05/17/2019
729952

Return
Get Date/Time String does not work for dates beyond 2/5/2040
When trying to get a string for dates 2/6/2040 and beyond, the Get Date/Time String will instead provide an earlier, incorrect date.

Workaround: Use the Format Date/Time String VI instead of Get Date/Time String

Reported Version: 2013 SP1  Resolved Version: N/A  Added: 05/17/2019
732570

Return
System decoration frame bleeds through system checkbox boolean text
In a System Tab Control with a System Decoration frame, the color bleeds through the boolean text of a system checkbox.

Workaround: Use a normal button control configured as an indicator behind the boolean text, and resize it to match the width of the text.

Reported Version: 2016  Resolved Version: N/A  Added: 05/17/2019

Document last updated on 12/6/2019

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).