USB-8501 Specifications
- Updated2023-02-20
- 5 minute(s) read
USB-8501 Specifications
This document lists specifications for the USB-85011-port and 2-port low-speed/fault-tolerant CAN interface device.
Definitions
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
- Typical specifications describe the performance met by a majority of models.
- Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.
Specifications are Typical unless otherwise noted.
Conditions
Specifications are typical at 0 °C to 55 °C unless otherwise noted.
Bus Interface
USB | USB 2.0 High-Speed |
Power Requirements
USB 2.0, bus-powered device
Input voltage | 4.5 V min, 5.25 V max |
Working mode current | 500 mA maximum, 250 mA typical (2 ports), 200 mA typical (1 port) |
USB suspend current | 2.5 mA maximum |
Physical Characteristics
Dimensions
1 port | 8.38 cm x 10.29 cm x 2.49 cm (3.30 in. x 4.05 in. x 0.98 in.) |
2 port | 9.27 cm x 10.29 cm x 2.49 cm (3.65 in. x 4.05 in. x 0.98 in.) |
Weight
1 port | 207 g (7.30 oz) |
2 port | 215 g (7.58 oz) |
Cable Length
Captive USB cable length | 2 m |
I/O Connectors
USB | Standard Type A plug |
High-Speed CAN Interface | 9-pin male D-SUB |
Sync Port (only on 2-port variant) | 3-pin Combicon |
Environmental
Operating Environment
Ambient temperature | 0 °C to 55 °C |
Relative humidity | 10% to 90%, noncondensing |
Maximum altitude | 2,000 m (800 mbar) at 25 °C ambient temperature |
Indoor use only.
Storage Environment
Ambient temperature | -20 °C to 70 °C |
Relative humidity | 5% to 95%, noncondensing |
Pollution Degree | 2 |
Low-Speed CAN Characteristics
Transceiver | NXP TJA1055T |
Max baud rate | 125 Kbps |
CAN_H, CAN_L bus lines voltage | -27 VDC to +40 VDC |
Onboard Termination (to RTH and RTL)
Termination disabled | 4.99 kΩ |
Termination enabled | 1.12 kΩ |
Sync Port
I/O compatibility | 5V TTL compatible |
Number of generic triggers[1] | 2 |
Supported Input Time base frequencies | 1 MHz, 10 MHz, and 20 MHz with auto detection |
Supported Output Time base frequency | 1 MHz |
Isolation
The USB-8501 offers port-to-port (2-port variant) and port-to-USB (both 1 port and 2 port) isolation.
Isolation Voltage
|
Maximum Voltage on CAN Ports
This voltage is the maximum voltage that can be applied or output without creating a safety hazard.
Connect only the voltages that are within these limits.
Port-to-COM | -27 VDC to +40 VDC max, Measurement Category I |
Measurement Category I is for measurement performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
Safety Compliance Standards
This device is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
- IEC 61010-1, EN 61010-1
- UL 61010-1, CSA C22.2 No. 61010-1
Electromagnetic Compatibility Standards
This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
- EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
- EN 55011 (CISPR 11): Group 1, Class A emissions
- EN 55022 (CISPR 22): Class A emissions
- EN 55024 (CISPR 24): Immunity
- AS/NZS CISPR 11: Group 1, Class A emissions
- AS/NZS CISPR 22: Class A emissions
- FCC 47 CFR Part 15B: Class A emissions
- ICES-001: Class A emissions
CE Compliance

This product meets the essential requirements of applicable European Directives, as follows:
- 2014/30/EU; Electromagnetic Compatibility Directive (EMC)
- 2011/65/EU; Restriction of Hazardous Substances (RoHS)
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.
EU and UK Customers
电子信息产品污染控制管理办法(中国RoHS)
1 Each generic trigger can be configured independently as input or output, clock or trigger. Refer to the NI-XNET Hardware and Software Help for details.
In This Section
- Definitions
- Conditions
- Bus Interface
- Power Requirements
- Physical Characteristics
- Environmental
- Low-Speed CAN Characteristics
- Onboard Termination (to RTH and RTL)
- Sync Port
- Isolation
- Maximum Voltage on CAN Ports
- Safety Compliance Standards
- Electromagnetic Compatibility Standards
- CE Compliance
- Product Certifications and Declarations
- Environmental Management