Predefined Properties
Refer to the following table to learn more about the predefined properties you can view and interact with in the SystemLink web application.
Property | Full name or key | Description | API(s) | Example value |
---|---|---|---|---|
Path | path | Path to the tag reference Note A tag path uses dot separators to
separate each component of the path. For example, a tag path looks
like
<system>.<namespace>.<tag>. |
Tag | 39a98f00-7200-461b-8a7r-e8c84dc3094d.Throughput_Test.status |
Current Value | value | Most recent value of the tag | Tag | June 04, 2019 2:34:04 AM CDT |
Minimum Aggregate Value | min | Smallest value of a tag | Tag | 0 |
Maximum Aggregate Value | max | Largest value of a tag | Tag | 69,905,949,604 |
Mean Value | avg | Average value of a tag | Tag | 34,952,974,802 |
Count | count | Number of times a tag produced a value | Tag | 11819 |
Batch Serial Number | nitmBatchSerialNumber | Serial number assigned to a batch of DUTs or UUTs in TestStand | Test Monitor | 0123456789 |
Serial Number | nitmSerialNumber | Serial number assigned to the DUT or UUT in TestStand. | Test Monitor | 1E28B2D |
Test Socket Index | nitmTestSocketIndex | Indexed number associated with a test socket | Test Monitor | 4 |
Test Socket Count | nitmTestSocketCount | Total number of test sockets included in the TestStand test sequence | Test Monitor | 5 |
Source | nitmSource | What software application acquired the test results | Test Monitor | niteststand |
Started At | nitmTestStandStartTime | Time when the test started running in TestStand | Test Monitor | 2019-04-29T14:37:26.467 |
Test Program | nitmTestProgram | Name of the test program that executes the test steps | Test Monitor | Manufacturing Test.seq |
Process Model | nitmProcessModel | Set of operations that establishes how TestStand performs a test on a DUT or UUT | Test Monitor | Sequential |
Operator | nitmOperator | Person who executes the test | Test Monitor | Administrator |
Batch ID | nitmBatchId | Identifier assigned to a batch of DUTs or UUTs in TestStand. | Test Monitor | 1 |
System Name | nitmSystemName | Name of the test system performing the test | Test Monitor | VirtualBox--MAC-08-00-27-C1-70-57 |
Hostname | nitmHostname | Name assigned to the device | Test Monitor | localhost |
Part Number | nitmPartNumber | Unique number assigned to a test device or asset | Test Monitor | 154119E-01L |
Product | nitmProduct | Type of device under test | Test Monitor | cRIO-9030 |
Value | value | Value associated with the process your team started monitoring when the alarm transition generates | Alarm | 15 |
Minion ID | minionId | Unique identifier associated with a client system Note When you query the Alarm service,
it translates the minion ID into the hostname in the SystemLink web
application. |
|
cRIO-9068--SN-190D5D5--MAC-00-80-2F-15-AF-CC |