SWB-2811 Overview
- Updated2023-02-20
- 5 minute(s) read
SWB-2811 Overview
SWB-2811 Pinout
Type A
Signal | Description |
---|---|
ABx | Analog bus row connection |
Cx | Column connection |
GND | Safety interlock ground connection |
INTRLK | Safety interlock resistor connection |
— | No connection |
Type B
Signal | Description |
---|---|
Cx | Column connection |
GND | Safety interlock ground connection |
INTRLK | Safety interlock resistor connection |
— | No connection |
SWB-2811 Topology
Multiple modules of the same type can be combined. The following table lists possible topologies.
Number of Modules | Topology |
---|---|
1 | 1-Wire 8×21 Matrix |
2 | 1-Wire 8×42 Matrix |
3 | 1-Wire 8×63 Matrix |
4 | 1-Wire 8×84 Matrix |
5 | 1-Wire 8×105 Matrix |
6 | 1-Wire 8×126 Matrix |
1-Wire 8×21 Matrix
Module software name: Configured Topology (NISWITCH_TOPOLOGY_CONFIGURED_TOPOLOGY)
Hardware Diagram
Making a Connection
The immediate operation, the niSwitch Connect Channels VI or the niSwitch_Connect function with parameters card1r2 and c1 result in the following connection:
- signal connected to CARD1R2 is routed to C1
Relay Names
Refer to the following list for relay names of one module.
- kCARD1AB0
- kCARD1AB1
- kCARD1AB2
- kCARD1AB3
- kCARD1AB4
- kCARD1AB5
- kCARD1AB6
- kCARD1AB7
- kCARD1R0C0...kCARD1R0C20
- kCARD1R1C0...kCARD1R1C20
- kCARD1R2C0...kCARD1R2C20
- kCARD1R3C0...kCARD1R3C20
- kCARD1R4C0...kCARD1R4C20
- kCARD1R5C0...kCARD1R5C20
- kCARD1R6C0...kCARD1R6C20
- kCARD1R7C0...kCARD1R7C20
SWB-2811 Relay Replacement
The module uses reed relays.
Relay | Relay Manufacturer | Part Number |
---|---|---|
Matrix | Meder | MS05-BV50980 |
Safety (K17, K58, K83, and K116) | Tyco Electronics | 5-1462039-8 |
Relay Kit | Part Number |
---|---|
National Instruments (10 matrix relays) | 781450-10 |
National Instruments (10 safety relays) | 781089-10 |
Complete the following sets of steps to locate and replace a failed relay.
Locate the Relay
- Ground yourself using a grounding strap or a ground connected to your PXI
chassis. Note Properly grounding yourself prevents damage to your module from electrostatic discharge.
- Locate the relay you want to replace. Refer to the following figure and table
for relay locations.
The relay names in the following table correspond to a single-card device.
Relay Name | Reference Designator | Relay Name | Reference Designator | Relay Name | Reference Designator | Relay Name | Reference Designator |
---|---|---|---|---|---|---|---|
kcard1ab0 | K16 | kcard1r1c15 | K31 | kcard1r3c17 | K97 | kcard1r5c19 | K98 |
kcard1ab1 | K25 | kcard1r1c16 | K39 | kcard1r3c18 | K56 | kcard1r5c20 | K99 |
kcard1ab2 | K49 | kcard1r1c17 | K47 | kcard1r3c19 | K65 | kcard1r6c0 | K146 |
kcard1ab3 | 57 | kcard1r1c18 | K24 | kcard1r3c20 | K66 | kcard1r6c1 | K153 |
kcard1ab4 | K82 | kcard1r1c19 | K32 | kcard1r4c0 | K100 | kcard1r6c2 | K160 |
kcard1ab5 | K91 | kcard1r1c20 | K33 | kcard1r4c1 | K108 | kcard1r6c3 | K147 |
kcard1ab6 | K115 | kcard1r2c0 | K50 | kcard1r4c2 | K117 | kcard1r6c4 | K154 |
kcard1ab7 | K124 | kcard1r2c1 | K59 | kcard1r4c3 | K101 | kcard1r6c5 | K161 |
kcard1r0c0 | K1 | kcard1r2c2 | K67 | kcard1r4c4 | K109 | kcard1r6c6 | K148 |
kcard1r0c1 | K9 | kcard1r2c3 | K51 | kcard1r4c5 | K118 | kcard1r6c7 | K155 |
kcard1r0c2 | K18 | kcard1r2c4 | K60 | kcard1r4c6 | K102 | kcard1r6c8 | K162 |
kcard1r0c3 | K2 | kcard1r2c5 | K68 | kcard1r4c7 | K110 | kcard1r6c9 | K149 |
kcard1r0c4 | K10 | kcard1r2c6 | K52 | kcard1r4c8 | K119 | kcard1r6c10 | K156 |
kcard1r0c5 | K19 | kcard1r2c7 | K61 | kcard1r4c9 | K103 | kcard1r6c11 | K157 |
kcard1r0c6 | K3 | kcard1r2c8 | K69 | kcard1r4c10 | K111 | kcard1r6c12 | K150 |
kcard1r0c7 | K11 | kcard1r2c9 | K53 | kcard1r4c11 | K120 | kcard1r6c13 | K151 |
kcard1r0c8 | K20 | kcard1r2c10 | K62 | kcard1r4c12 | K104 | kcard1r6c14 | K158 |
kcard1r0c9 | K4 | kcard1r2c11 | K70 | kcard1r4c13 | K112 | kcard1r6c15 | K145 |
kcard1r0c10 | K12 | kcard1r2c12 | K54 | kcard1r4c14 | K121 | kcard1r6c16 | K152 |
kcard1r0c11 | K21 | kcard1r2c13 | K63 | kcard1r4c15 | K105 | kcard1r6c17 | K159 |
kcard1r0c12 | K5 | kcard1r2c14 | K71 | kcard1r4c16 | K113 | kcard1r6c18 | K106 |
kcard1r0c13 | K13 | kcard1r2c15 | K55 | kcard1r4c17 | K122 | kcard1r6c19 | K114 |
kcard1r0c14 | K22 | kcard1r2c16 | K64 | kcard1r4c18 | K73 | kcard1r6c20 | K107 |
kcard1r0c15 | K6 | kcard1r2c17 | K72 | kcard1r4c19 | K81 | kcard1r7c0 | K167 |
kcard1r0c16 | K14 | kcard1r2c18 | K40 | kcard1r4c20 | K74 | kcard1r7c1 | K174 |
kcard1r0c17 | K23 | kcard1r2c19 | K48 | kcard1r5c0 | K125 | kcard1r7c2 | K175 |
kcard1r0c18 | K7 | kcard1r2c20 | K41 | kcard1r5c1 | K132 | kcard1r7c3 | K168 |
kcard1r0c19 | K15 | kcard1r3c0 | K75 | kcard1r5c2 | K139 | kcard1r7c4 | K169 |
kcard1r0c20 | K8 | kcard1r3c1 | K84 | kcard1r5c3 | K126 | kcard1r7c5 | K176 |
kcard1r1c0 | K26 | kcard1r3c2 | K92 | kcard1r5c4 | K133 | kcard1r7c6 | K163 |
kcard1r1c1 | K34 | kcard1r3c3 | K76 | kcard1r5c5 | K140 | kcard1r7c7 | K170 |
kcard1r1c2 | K42 | kcard1r3c4 | K85 | kcard1r5c6 | K127 | kcard1r7c8 | K177 |
kcard1r1c3 | K27 | kcard1r3c5 | K93 | kcard1r5c7 | K134 | kcard1r7c9 | K164 |
kcard1r1c4 | K35 | kcard1r3c6 | K77 | kcard1r5c8 | K141 | kcard1r7c10 | K171 |
kcard1r1c5 | K43 | kcard1r3c7 | K86 | kcard1r5c9 | K128 | kcard1r7c11 | K178 |
kcard1r1c6 | K28 | kcard1r3c8 | K94 | kcard1r5c10 | K135 | kcard1r7c12 | K165 |
kcard1r1c7 | K36 | kcard1r3c9 | K78 | kcard1r5c11 | K142 | kcard1r7c13 | K172 |
kcard1r1c8 | K44 | kcard1r3c10 | K87 | kcard1r5c12 | K129 | kcard1r7c14 | K179 |
kcard1r1c9 | K29 | kcard1r3c11 | K95 | kcard1r5c13 | K136 | kcard1r7c15 | K166 |
kcard1r1c10 | K37 | kcard1r3c12 | K79 | kcard1r5c14 | K143 | kcard1r7c16 | K173 |
kcard1r1c11 | K45 | kcard1r3c13 | K88 | kcard1r5c15 | K130 | kcard1r7c17 | K180 |
kcard1r1c12 | K30 | kcard1r3c14 | K96 | kcard1r5c16 | K137 | kcard1r7c18 | K123 |
kcard1r1c13 | K38 | kcard1r3c15 | K80 | kcard1r5c17 | K144 | kcard1r7c19 | K131 |
kcard1r1c14 | K46 | kcard1r3c16 | K89 | kcard1r5c18 | K90 | kcard1r7c20 | K138 |
Replace the Relay
The module uses lead-free assemblies.
Make sure that you have the following items:
- Temperature-regulated soldering iron set to 371 °C (700 °F) for lead-free solder rework
- 96.5/3.0/0.5 Tin/Silver/Copper solder (flux core) for lead-free solder rework
- Solder wick
- Fine pick
- Isopropyl alcohol
- Cotton swabs
Replace the relay as you would any other through-hole part. Trim the replaced relay leads to no more than 0.5 mm (0.02 inch) from the PCB.