sbRIO-9220 Specifications
- Updated2023-02-20
- 5 minute(s) read
sbRIO-9220 Specifications
Definitions
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
- Typical specifications describe the performance met by a majority of models.
- Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.
Specifications are Typical unless otherwise noted.
Conditions
Specifications are valid for the range -40 °C to 70 °C unless otherwise noted. All voltages are relative to the AI- signal on each channel unless otherwise noted.
Input Characteristics
Number of channels | 16 analog input channels | ||||||||||||||
ADC resolution | 16 bits | ||||||||||||||
Type of ADC | Successive approximation register (SAR) | ||||||||||||||
| |||||||||||||||
Overvoltage protection | ±30 V | ||||||||||||||
Conversion time | 10 μs minimum | ||||||||||||||
Sample rate | 100 kS/s maximum |
Measurement Conditions | Percent of Reading (Gain Error) | Percent of Range[2] (Offset Error) | |
---|---|---|---|
Calibrated | Maximum (-40 °C to 70 °C) | 0.142% | ±0.070% |
Typical (23 °C ±5 °C) | 0.010% | ±0.001% | |
Uncalibrated[3] | Maximum (-40 °C to 70 °C) | 0.350% | ±0.360% |
Typical (23 °C ±5 °C) | 0.060% | ±0.070% |
| |||||||
CMRR (fin = 60 Hz) | 70 dB | ||||||
-3 dB bandwidth | >100 kHz | ||||||
Input impedance | >1 GΩ | ||||||
Input noise | 0.85 LSBrms | ||||||
Crosstalk | -90 dB | ||||||
| |||||||
No missing codes | 15 bits | ||||||
MTBF | 1,522,250 at 25 °C; Bellcore Issue 6, Method 1, Case 3, Limited Part Stress Method |
Power Requirements
| |||||||
|
Physical Characteristics
Dimensions and Weight
Connector type | Spring terminal |
Weight | 64.4 g (2.27 oz) |
Spring-Terminal Wiring Specifications
Gauge | 0.14 mm2 to 1.5 mm2 (26 AWG to 16 AWG) copper conductor wire | ||||||||
Wire strip length | 10 mm (0.394 in.) of insulation stripped from the end | ||||||||
Temperature rating | 90 °C minimum | ||||||||
Wires per terminal | One wire per spring terminal; two wires per spring terminal using a 2-wire ferrule | ||||||||
| |||||||||
|
Safety Voltages
Isolation
Voltages
Temporary Overvoltage—An overvoltage condition of a relatively long duration.
Channel-to-channel | None | ||||||
| |||||||
Temporary overvoltage protection | ±30 V between any two pins |
Measurement Category
Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe.
Environmental Characteristics
| |||||||
| |||||||
Pollution Degree | 2 | ||||||
Maximum altitude | 4,000 m |
Compliance Standards
Environmental Standards
This product meets the requirements of the following environmental standards for electrical equipment.
- IEC 60068-2-1 Cold
- IEC 60068-2-2 Dry heat
EMC Standards
This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
- EN 61326-1 (IEC 61326-1): Class A emissions; Industrial immunity
- EN 55011 (CISPR 11): Group 1, Class A emissions
- AS/NZS CISPR 11: Group 1, Class A emissions
- ICES-001: Class A emissions
Safety Compliance Standards
This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
- IEC 61010-1, EN 61010-1
- UL 61010-1, CSA C22.2 No. 61010-1
Calibration
Calibration interval | 1 year |
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.
EU and UK Customers
电子信息产品污染控制管理办法(中国RoHS)
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
NI Services
Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples.
Visit ni.com/services to learn about NI service offerings such as calibration options, repair, and replacement.
Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI.
NI corporate headquarters is located at 11500 N Mopac Expwy, Austin, TX, 78759-3504, USA.
1 The minimum measurement voltage range is the largest voltage the sbRIO-9220 is guaranteed to accurately measure.
2 Range equals ±10.5 V.
3 Uncalibrated accuracy refers to the accuracy achieved when acquiring in raw or unscaled modes where the calibration constants stored in the module are not applied to the data.