ModAcc:Measurement Length (slots)

Specifies the duration of the modulation accuracy (ModAcc) measurement. This value is expressed in slots. The default value is 1. The valid values are 1 to 16, inclusive. The sum of the ModAcc measurement offset and the ModAcc measurement length must be less than or equal to 16.

Remarks

The following table lists the characteristics of this property.

Short Name ModAcc Meas Length (slots)
Data type ci32.png
Permissions Read/Write