ModAcc:Synchronization Mode Property
- Updated2024-04-10
- 1 minute(s) read
ModAcc:Synchronization Mode Property
Short Name: ModAcc Sync Mode
Property of RFmxNR
Specifies whether the measurement is performed from slot or frame boundary.
You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.
The default value is Slot.
Slot (1) |
The measurement is performed over the ModAcc Meas Length starting at the ModAcc Meas Offset from the slot boundary. If you set the Trigger Type property to Digital Edge, the measurement expects the digital trigger at the slot boundary. |
Frame (5) |
The measurement is performed over the ModAcc Meas Length starting at ModAcc Meas Offset from the frame boundary. If you set the Trigger Type property to Digital Edge, the measurement expects the digital trigger from the frame boundary. |
SSB Start Frame (7) |
The measurement is performed over the ModAcc Meas Length starting at ModAcc Meas Offset from the frame boundary. If you set the Trigger Type property to Digital Edge, the measurement expects the digital trigger from the boundary of the frame having SSB. |
Remarks
The following table lists the characteristics of this property.
Datatype | |
Permissions | Read/Write |
High-level VIs | N/A |
Resettable | Yes |