PXIe-8861 Specifications
- Updated2024-09-05
- 5 minute(s) read
PXIe-8861 Specifications
Features
CPU | Intel® Xeon® Processor E3-1515M v5 |
Cache | 8 MB SmartCache |
Quad-Channel DDR4-2133 (PC-17000) | 8 GB standard, 32 GB maximum |
Storage | 512 GB (or greater) solid-state, NVME |
Video | 1 DisplayPort 1.1, 1 DisplayPort 1.2 |
Ethernet |
1 i219 port; 1 i210 port, 1588, 10/100/1000 Base T |
PXI Express 4 Link Configuration | x4, x4, x4, x4 |
PXI Express 2 Link Configuration | x8, x8 |
GPIB (IEEE 488 Controller) | 1 mini-GPIB |
Serial Port (RS-232) | 1 DB-9 |
Thunderbolt 3 Ports | 2 Type-C |
Hi-Speed USB (2.0) Ports | 4 Type-A |
SuperSpeed USB (3.0) Ports | 2 Type-A |
PXI Trigger Bus Input/Output | 1 SMB |
Installed Operating System | Windows 10 IoT Enterprise or NI Linux Real-Time |
Trusted Platform Module | Optional TPM 2.0 (Infineon/ST TPM for global market, no TPM available for China market) |
Front Panel Dimensions
The following figure shows the front panel layout and dimensions of the PXIe-8861. Dimensions are in inches (millimeters).
Electrical
Voltage (V) | Current (Amps) Typical | Current (Amps) Maximum |
---|---|---|
+3.3 V | 3.75 A | 4.25 A |
+5 V | 2.0 A | 2.5 A |
+12 V | 6.0 A | 7.6 A |
-12 V | 0 A | 0 A |
+5 VAux | 0.75 A | 0.8 A |
Physical
Board dimensions | Four-wide 3U PXI Express module |
Slot requirements | One system slot plus three controller expansion slots |
Compatibility | Fully compatible with PXI Express Specification 1.0 |
Weight | 1.2 kg (2.6 lb) typical |
Environmental
Maximum altitude | 4,600 m (570 mbar) (at 25 °C ambient) |
Pollution Degree | 2 |
Indoor use only.
Operating Environment
Ambient temperature range | 0 °C to 55 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.) |
Relative humidity range | 10% to 90%, noncondensing (Tested in accordance with IEC-60068-2-56.) |
Storage Environment
Ambient temperature range[1]1 CPU performance may decrease for some workloads if a unit is stored at the extreme ambient temperature range and then subjected to max nonoperating random vibration limits. | -40 °C to 71 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 limits.) |
Relative humidity range | 5% to 95%, noncondensing (Tested in accordance with IEC 60068-2-56.) |
Shock and Vibration
Operating shock | 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Meets MIL-PRF-28800F Class 2 limits.) | ||||||
|
Safety
- IEC 61010-1, EN 61010-1
- UL 61010-1, CSA C22.2 No. 61010-1
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
- EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
- EN 55011 (CISPR 11): Group 1, Class A emissions
- EN 55022 (CISPR 22): Class A emissions
- EN 55024 (CISPR 24): Immunity
- AS/NZS CISPR 11: Group 1, Class A emissions
- AS/NZS CISPR 22: Class A emissions
- FCC 47 CFR Part 15B: Class A emissions
- ICES-001: Class A emissions
CE Compliance

This product meets the essential requirements of applicable European Directives, as follows:
- 2014/35/EU; Low-Voltage Directive (safety)
- 2014/30/EU; Electromagnetic Compatibility Directive (EMC)
- 2011/65/EU; Restriction of Hazardous Substances (RoHS)
- 2014/53/EU; Radio Equipment Directive (RED)
- 2014/34/EU; Potentially Explosive Atmospheres (ATEX)
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.
EU and UK Customers
Battery Replacement and Disposal
电子信息产品污染控制管理办法(中国RoHS)
1 CPU performance may decrease for some workloads if a unit is stored at the extreme ambient temperature range and then subjected to max nonoperating random vibration limits.