PXIe-6509 Specifications

This document lists specifications for the PXIe-6509, 96-channel, 5 V TTL/CMOS, 24 mA PXI Digital I/O Module.

Definitions

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.

  • Typical specifications describe the performance met by a majority of models.
  • Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.

Specifications are Typical unless otherwise noted.

Conditions

Specifications are typical at 25 °C unless otherwise noted.

Digital I/O

Number of channels

96 input/output

Compatibility

TTL Schmitt Trigger/CMOS, single-ended GND reference

Power-on state

Input pulled up or down (software-selectable),

output 1 or 0

Data transfers

Interrupts, programmed I/O

I/O connector

100-pin female 0.050 series SCSI

Pull resistor

Pull-up resistor

4.7 kΩ (typical)

Pull-down resistor

47 kΩ (typical)

Input voltage protection

±20 V on up to two pins, maximum

Digital Logic Levels

Input Signals

Level Minimum Maximum
Input voltage (Vin) 0 V 5 V
Positive-going threshold (VT+) 2.2 V
Negative-going threshold (VT– ) 0.8 V
Delta VT hysteresis (VT+ – VT–) 0.2 V
Input high current (IIH) (Vin = 5 V, resistors set to pull-up) 260 µA
Input high current (IIH) (Vin = 5 V, resistors set to pull-down) 260 µA
Input low current (IIL) (Vin = 0 V, resistors set to pull-up) –1250 µA
Input low current (IIL) (Vin = 0 V, resistors set to pull-down) –20 µA

Output Signals

Level Minimum Maximum
High-level output current (IOH) –24 mA
Low-level output current (IOL) 24 mA
Output voltage (Vout) 0 V 5.5 V
Output high voltage (VOH), at –24 mA 3.4 V
Output low voltage (VOL), at 24 mA 0.78 V

The total current sinking/sourcing from one port cannot exceed 100 mA.

Power Requirements

Current draw from bus during no-load condition

Typical

575 mA on +3.3 VDC;

20 mA on +12 VDC

Peak

700 mA on +3.3 VDC;

90 mA on +12 VDC

+5 V power available at I/O connector (pins 49 and 99)

+4.0 V to 5.25 V;

1A, maximum

Note The voltage at the I/O connector depends on the amount of current drawn from the PXIe-6509.

Physical Characteristics

Printed circuit board dimensions

Standard 3U PXI

Dimensions (without connectors)

14.2 cm × 10.4 cm (5.6 in. × 4.1 in.)

Weight

140 g (4.8 oz)

I/O Connector

100-pin SCSI

Environmental Guidelines

Notice This model is intended for use in indoor applications only.

Environmental Characteristics

Temperature

Operating

0 °C to 55 °C

Storage

–40 °C to 71 °C

Humidity

Operating

10% to 90%, noncondensing

Storage

5% to 95%, noncondensing

Pollution Degree

2

Maximum altitude

2,000 m (at 25 °C ambient temperature)

Shock and Vibration

Operating vibration

5 Hz to 500 Hz, 0.3 g RMS

Non-operating vibration

5 Hz to 500 Hz, 2.4 g RMS

Operating shock

30 g, half-sine, 11 ms pulse

Environmental Management

NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.

For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.

EU and UK Customers
  • Waste Electrical and Electronic Equipment (WEEE)—At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee.
  • 电子信息产品污染控制管理办法(中国RoHS)
  • 中国RoHSNI符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于NI中国RoHS合规性信息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)
  • Environmental Standards

    This product meets the requirements of the following environmental standards for electrical equipment.

    • IEC 60068-2-1 Cold
    • IEC 60068-2-2 Dry heat
    • IEC 60068-2-78 Damp heat (steady state)
    • IEC 60068-2-64 Random operating vibration
    • IEC 60068-2-27 Operating shock
    • MIL-PRF-28800F
      • Low temperature limits for operation Class 3, for storage Class 3
      • High temperature limits for operation Class 2, for storage Class 3
      • Random vibration for non-operating Class 3
      • Shock for operating Class 2

    Absolute Maximum Voltage Rating

    Absolute maximum voltage rating refers to the peak voltage recommended during normal operation, including transient voltages. Refer to Digital Logic Levels for the maximum voltage input and output.

    Channel-to-earth

    -0.5 V to 5.5 V, Measurement Category I

    Caution Do not connect the PXIe-6509 to signals or use for measurements within Measurement Categories II, III, or IV.
    Attention Ne connectez pas le PXIe-6509 à des signaux et ne l'utilisez pas pour effectuer des mesures dans les catégories de mesure II, III ou IV.

    Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.

    Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are for other circuits not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV.

    Safety Compliance Standards

    This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:

    • IEC 61010-1, EN 61010-1
    • UL 61010-1, CSA C22.2 No. 61010-1
    Note For safety certifications, refer to the product label or the Product Certifications and Declarations section.

    Electromagnetic Compatibility Standards

    This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:

    • EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
    • EN 55011 (CISPR 11): Group 1, Class A emissions
    • AS/NZS CISPR 11: Group 1, Class A emissions
    Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes.
    Note In Australia and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations.
    Notice For EMC declarations and certifications, and additional information, refer to the Product Certifications and Declarations section.

    CE Compliance

    This product meets the essential requirements of applicable European Directives, as follows:

    • 2014/30/EU; Electromagnetic Compatibility Directive (EMC)
    • 2011/65/EU; Restriction of Hazardous Substances (RoHS)

    Product Certifications and Declarations

    Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.

    Additional Resources

    Visit ni.com/manuals for more information about your product, including specifications, pinouts, and instructions for connecting, installing, and configuring your system.

    NI Services

    Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples.

    Visit ni.com/services to learn about NI service offerings such as calibration options, repair, and replacement.

    Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI.

    NI corporate headquarters is located at 11500 N Mopac Expwy, Austin, TX, 78759-3504, USA.