PXIe-5605 Downconverter IF Filter
You can allow NI-RFSA to automatically control IF filtering or you can manually select the IF filter.
Manual selection is useful when the PXIe-5622 IF digitizer is not being used as well as in other applications, such as in-band retuning.
The PXIe-5605 supports the following IF bandpass filters:
IF Filter Selection in Spectrum Acquisitions
For spectrum acquisitions, NI-RFSA automatically selects the appropriate filter based on the requested acquisition span.
You can change the bandwidth using the Device Instantaneous Bandwidth property or the NIRFSA_ATTR_DEVICE_INSTANTANEOUS_BANDWIDTH attribute. You can use this property or attribute to determine the actual bandwidth achieved by the downconverter in (external digitizer mode) or the PXIe-5665.
IF Filter Selection in I/Q Acquisitions
For I/Q acquisitions, NI-RFSA defaults to the widest IF bandwidth available.