PXIe-2738 Specifications
- Updated2023-02-19
- 7 minute(s) read
PXIe-2738 Specifications
This document lists specifications for the PXIe-2738 . All specifications are subject to change without notice.
PXIe-2738
Specifications
Specifications characterize the warranted performance of the instrument under the stated operating conditions. Data in this document are Specifications unless otherwise noted.
Typical Specifications are specifications met by the majority of the instrument under the stated operating conditions and are tested at 23 °C ambient temperature. Typical specifications are not warranted.
All voltages are specified in DC, ACpk, or a combination unless otherwise specified.
Topology
Topology | 2-wire 8 × 32 matrix |
Input Characteristics
|
Measurement Categories CAT I and CAT O (Other) are equivalent and are for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. This category is for measurement of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special hardware, limited-energy parts of hardware, circuits powered by regulated low-voltage sources, and electronics.
Maximum switching power | 60 W, 62.5 VA |
| |||||||
Minimum switching load | 20 mV/1 mA |
DC isolation resistance (channel-to-COM) | 1 GΩ (typical at 25º C) | ||||||
|
Thermal EMF | <10 µV |
RF Performance Characteristics
| |||||||||
| |||||||||
|
Dynamic Characteristics
| |||||||||||
Simultaneous drive limit | 90 relays | ||||||||||
Expected mechanical relay life | 1 × 108 cycles | ||||||||||
|
Physical Characteristics
Relay type | Electromechanical, non-latching | ||||||||||
Relay contact material | Palladium-ruthenium, gold covered | ||||||||||
Front panel connector | 160 DIN 41612, 160 positions, male | ||||||||||
| |||||||||||
Dimensions (L × W × H) | 3U, one slot, PXI/cPCI module, PXI Express compatible 21.6 cm × 2.0 cm × 13.0 cm (8.5 in. × 0.8 in. × 5.1 in.) | ||||||||||
Weight | 423 g (14.9 oz) |
Environment
Maximum altitude | 2,000 m (800 mbar) (at 25 °C ambient temperature) |
Pollution Degree | 2 |
Indoor use only.
Operating Environment
Ambient temperature range | 0 °C to 55 °C |
Relative humidity range | 10% to 90%, noncondensing |
Storage Environment
Ambient temperature range | -40 °C to 71 °C |
Relative humidity range | 5% to 95%, noncondensing |
Shock and Vibration
Operating shock | 30 g peak, half-sine, 11 ms pulse | ||||||
|
Derating
PXIe-2738
Load at >50 °C
-
Use the following equation to calculate the load:where Channels is the number of channels that simultaneously carry a signal, Current, for 1, ... , n.
-
Verify that the load at your ambient operating temperature falls within the shaded region of the following figure.
Figure 1. PXIe-2738 Load Derating, 2-Wire
Module Load Derating at >50 °C
The following examples calculate supported derating conditions for the PXIe-2738 .
Example 1
where | 3 channels carry 2 A |
4 channels carry 1.7 A |
You can use this module at ambient temperatures between 0 °C and 55 °C.
Example 2
where | 8 channels carry 2 A |
You can use this module at ambient temperatures between 0 °C and 50 °C.
Compliance and Certifications
Safety Compliance Standards
This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
- IEC 61010-1, EN 61010-1
- UL 61010-1, CSA C22.2 No. 61010-1
Electromagnetic Compatibility
- EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
- EN 55011 (CISPR 11): Group 1, Class A emissions
- EN 55022 (CISPR 22): Class A emissions
- EN 55024 (CISPR 24): Immunity
- AS/NZS CISPR 11: Group 1, Class A emissions
- AS/NZS CISPR 22: Class A emissions
- FCC 47 CFR Part 15B: Class A emissions
- ICES-001: Class A emissions
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.