PXIe-1073 Specifications
- Updated2024-09-17
- 6 minute(s) read
PXIe-1073 Specifications
This document contains specifications for the PXIe-1073 chassis.
Electrical
The following section provides information about the PXIe-1073 AC input and DC output.
AC Input
Input voltage range | 100 to 240 VAC | ||||||||
Operating voltage range | 90 to 264 VAC | ||||||||
Input current rating | 4 to 2 A | ||||||||
Input frequency | 50/60 Hz | ||||||||
Operating frequency range[1]1 The operating range is guaranteed by design. | 47 to 63 Hz | ||||||||
| |||||||||
Efficiency | >70% at full load, normal input voltage | ||||||||
Power disconnect | The AC power cable provides main power disconnect. The front-panel power switch controls the internal chassis power supply that provides DC power to the CompactPCI/PXI backplane. |
DC Output
Voltage | Maximum Current |
---|---|
+3.3 V | 15 A |
+5 V | 7.5 A |
+12 V | 15 A |
-12 V | 0.75 A |
+5 VAUX | 1.0 A |
Over-current protection | All outputs protected from short circuit |
Over-voltage at | Minimum (Active Range) | Maximum (Active Range) |
---|---|---|
+3.3 V | 3.76 V | 4.3 V |
+5 V | 5.74 V | 7.0 V |
+12 V | 13.4 V | 15.6 V |
Chassis Cooling
Per slot cooling capacity | 38.25 W |
Module cooling system | Forced air circulation (positive pressurization) through a 126 CFM fan with High/Auto speed selector |
Slot airflow direction | Bottom of module to top of module |
Module cooling intake | Bottom of chassis |
Module cooling exhaust | Along rear, right side, and top of chassis |
Power supply cooling system | Forced air circulation through integrated fan |
Power supply cooling intake | Front side of chassis |
Power supply cooling exhaust | Rear side of chassis |
Environmental
Maximum altitude | 2,000 m (800 mbar) (at 25 °C ambient) |
Measurement Category | II |
Pollution Degree | 2 |
Indoor use only.
Operating Environment
Ambient temperature range | 0 °C to 50 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.) |
Relative humidity range | 20% to 80%, noncondensing (Tested in accordance with IEC-60068-2-56.) |
Storage Environment
Ambient temperature range | –40 °C to 71 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2. Meets MIL-PRF-28800F Class 3 limits.) |
Relative humidity range | 10% to 95%, noncondensing (Tested in accordance with IEC-60068-2-56.) |
Shock and Vibration
Operational shock | 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC-60068-2-27. Meets MIL-PRF-28800F Class 2 limits.) | ||||||
|
Sound Pressure Level (at Operator Position)
(Tested in accordance with ISO 7779. Meets MIL-PRF-28800F requirements.)
Auto fan (up to ~25 °C ambient) | 43.3 dBA |
High fan | 58.3 dBA |
Sound Power
Auto fan (up to ~25 °C ambient) | 51.3 dBA |
High fan | 64.6 dBA |
Safety Compliance Standards
This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
- IEC 61010-1, EN 61010-1
- UL 61010-1, CSA C22.2 No. 61010-1
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
- EN 61326 (IEC 61326): Class A emissions; Basic immunity
- EN 55011 (CISPR 11): Group 1, Class A emissions
- AS/NZS CISPR 11: Group 1, Class A emissions
- FCC 47 CFR Part 15B: Class A emissions
- ICES-001: Class A emissions
CE Compliance

This product meets the essential requirements of applicable European Directives, as follows:
- 2014/35/EU; Low-Voltage Directive (safety)
- 2014/30/EU; Electromagnetic Compatibility Directive (EMC)
- 2011/65/EU; Restriction of Hazardous Substances (RoHS)
- 2014/53/EU; Radio Equipment Directive (RED)
- 2014/34/EU; Potentially Explosive Atmospheres (ATEX)
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.
EU and UK Customers
电子信息产品污染控制管理办法(中国RoHS)
Backplane
Size | 3U-sized; one system slot (with three system expansion slots) and 5 peripheral slots. Compliant with IEEE 1101.10 mechanical packaging. PXI Express Specification compliant. Accepts both PXI Express and CompactPCI (PICMG 2.0 R 3.0) 3U modules. |
V (I/O)[2]2 V(I/O) is connected to the +5 V DC power plane, so the same specifications apply to V(I/O) and +5 V . | +5 |
Backplane bare-board material | UL 94 V-0 Recognized |
Backplane connectors | Conforms to IEC 917 and IEC 1076-4-101, UL 94 V-0 rated |
System Synchronization Clocks (PXI_CLK10, PXIe_CLK100, PXIe_SYNC100)
10 MHz System Reference Clock: PXI_CLK10
Maximum slot-to-slot skew | 250 ps |
Accuracy | ±25 ppm max (guaranteed over the operating temperature range) |
Maximum jitter | 5 ps RMS phase-jitter (10 Hz–1 MHz range) |
Duty-factor | 45% to 55% |
Unloaded signal swing | 3.3 V ±0.3 V |
100 MHz System Reference Clock: PXIe_CLK100 and PXIe_SYNC100
Maximum slot-to-slot skew | 100 ps |
Accuracy | ±25 ppm max (guaranteed over the operating temperature range) |
Maximum jitter | 3 ps RMS phase-jitter (10 Hz to 12 kHz range), 2 ps RMS phase-jitter (12 kHz to 20 MHz range) |
Duty-factor for PXIe_CLK100 | 45% to 55% |
Absolute differential voltage (When terminated with a 50 Ω load to 1.30 V or Thévenin equivalent) | 400 mV to 1000 mV |
Mechanical
|
Weight | 11.0 lb (5.0 kg) |
Chassis materials | Sheet Aluminum, Extruded Aluminum, Cold Rolled Steel, Nylon |
Finish | Clear Chromate Conversion Coat on Aluminum Electrodeposited Nickel Plate Plate on Cold Rolled Steel Polyester Urethane Powder Paint |
The following figures show the PXIe-1073 chassis dimensions. The holes shown are for the installation of the optional rack mount kits. You can install those kits on the front or rear of the chassis, depending on which end of the chassis you want to face toward the front of the instrument cabinet. Notice that the front and rear chassis mounting holes (size M4) are symmetrical.
- PXI-1031 Rack Mount Kit (P/N 778948-01)
- PXIe-1073 Chassis
In This Section
- Electrical
- Chassis Cooling
- Environmental
- Shock and Vibration
- Safety Compliance Standards
- Electromagnetic Compatibility
- CE Compliance
- Product Certifications and Declarations
- Environmental Management
- EU and UK Customers
- 电子信息产品污染控制管理办法(中国RoHS)
- Backplane
- System Synchronization Clocks (PXI_CLK10, PXIe_CLK100, PXIe_SYNC100)
- Mechanical