PXI-8517 Specifications
- Updated2023-02-19
- 4 minute(s) read
PXI-8517 Specifications
This document lists specifications for the PXI-8517 2-port Flexray interface module.
Definitions
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
- Typical specifications describe the performance met by a majority of models.
- Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.
Specifications are Typical unless otherwise noted.
Conditions
Specifications are typical at 0 °C to 55 °C unless otherwise noted.
Power Requirements
+5 VDC (±5%) | 210 mA |
+3.3 VDC (±5%) | 940 mA |
Physical
Dimensions and Weight
Dimensions | 10.67 cm x 16.76 cm (4.2 in. x 6.6 in.) |
Weight | 102 g (3.6 oz) |
RTSI/Front Panel Sync Connectors
Trigger lines | 7 input/output |
Clock lines | 1 input/output |
Front panel sync connectors | 2 input/output |
I/O compatibility | TTL |
Power-on state | Input (High-Z) |
Response | Rising edge triggers |
Physical Characteristics
Transceiver | NXP TJA1080 x 2 |
Max baud rate | 10 Mbps |
Min baud rate | 1 Mbps |
Environmental
Operating temperature | 0 °C to 55 °C |
Storage temperature | -20 °C to 70 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) |
Operating humidity | 10% to 90% RH, noncondensing |
Storage humidity | 5% to 95% RH, noncondensing (Tested in accordance with IEC-60068-2-56.) |
Maximum altitude | 2000 m |
Pollution Degree (IEC 60664) | 2 |
Indoor use only.
Shock
Operating shock | 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC-60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.) |
Random Vibration
Operating | 5 Hz to 500 Hz, 0.3 grms |
Nonoperating | 5 Hz to 500 Hz, 2.4 grms (Tested in accordance with IEC-60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) |
Safety
Isolation Voltages
| |||||||
|
Measurement Category I is for measurement performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
Safety Standards
- IEC 61010-1, EN 61010-1
- UL 61010-1, CSA 61010-1
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
- EN 61326 (IEC 61326): Class A emissions; Basic immunity
- EN 55011 (CISPR 11): Group 1, Class A emissions
- AS/NZS CISPR 11: Group 1, Class A emissions
- FCC 47 CFR Part 15B: Class A emissions
- ICES-001: Class A emissions
CE Compliance

This product meets the essential requirements of applicable European Directives, as follows:
- 2014/35/EU; Low-Voltage Directive (safety)
- 2014/30/EU; Electromagnetic Compatibility Directive (EMC)
- 2011/65/EU; Restriction of Hazardous Substances (RoHS)
- 2014/53/EU; Radio Equipment Directive (RED)
- 2014/34/EU; Potentially Explosive Atmospheres (ATEX)
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.