NI PCIe-1477 Specifications

The following specifications are typical at 25 °C unless otherwise noted.

Definitions

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.

  • Typical specifications describe the performance met by a majority of models.
  • Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.

Specifications are Typical unless otherwise noted.

Features

Supported camera standard

Camera Link 2.1

Supported configurations

Base, Medium, Full, 72-bit, 80-bit

Camera connectors

Two 26-pin SDR

General-purpose digital I/O connectors

One 15-pin high-density female D-SUB

Pixel clock

20 MHz to 85 MHz

Camera power

Dual Power over Camera Link (PoCL) with SafePower

Bus Interface

Form factor

x8 PCIe, specification v2.0 compliant

Slot compatibility

x8, and x16 PCIe slots

Up-plugging availability

x16

Note Some system devices limit data transfer rates for plug-in devices in an up-plugging configuration. Refer to the documentation provided by the computer manufacturer to determine if your computer will support a x8 plug-in device at a x8 data rate in a larger slot.

Reconfigurable FPGA

FPGA type

Kintex-7 325T

Number of flip-flops

407,600

Number of 6-input LUTs

203,800

Number of DSP48 slices (25 × 18 multipliers)

840

Embedded block RAM

16,020 kbits

TTL I/O

Number of channels

6

Type

Bidirectional

Voltage range

0 V to 5 V

Maximum pulse rate

2 MHz

Minimum pulse detected

500 ns

Power-on state

Input (high-impedance), 10 kΩ pull-up to 5 V

Logic levels

Input high voltage

2.57 V, minimum

Input low voltage

0.59 V, maximum

Output high voltage

4.12 V, minimum at 1.5 mA source

Output low voltage

0.37 V, maximum at 1.5 mA sink

Differential I/O

Number of channels

2

Type

Bidirectional (RS-422) or single-ended

Maximum pulse rate

5 MHz, differential

Differential input threshold

±0.2 V, maximum, RS-422 compatible

Differential output voltage

2.0 V min (RLOAD= 100 Ω)

Single-ended input voltage range

0 V DC to 5.5 V DC

TTL-compatible single-ended logic levels

Input high voltage

2.0 V, minimum

Input low voltage

0.8 V, maximum

Isolated Input

Number of channels

2

Type

Current sinking

Input voltage range

0 V to 30 V

Input ON voltage

3.5 V to 30 V

Input OFF voltage

0 V to 2 V

Turn-on current

7.1 mA; 14 mA, maximum

Maximum pulse rate

100 kHz

Minimum pulse detected

10 µs

Reverse polarity protection

Yes, -30 V

FPGA External Memory

Type

DDR3L SDRAM

Density

2,048 MB

Theoretical data rate

10.66 GB/s, maximum

Clocks

Pixel clock frequency range

20 MHz to 85 MHz[1]

Note The Camera Link specification requires cameras to transmit at a minimum of 20 MHz.

Serial Interface

Baud rates supported

9.6, 19.2, 38.4, 57.6, 115.2, 230.4, 460.8, or 921.6 kbps

RTSI

Number of channels

8

Camera Link I/O Extension

This extension I/O is available with the addition of the Camera Link I/O Extension Board (e.g., part number 780869-01 for PCIe or 779352-01 for PCI). See the appropriate Camera Link I/O Extension Board User Guide on ni.com/manuals for additional details and specifications.

Extension supported

Yes

TTL I/O

8

Isolated inputs

3

Isolated outputs

3

Quadrature encoder inputs

1 (two RS-422 or single-ended inputs)

Power Requirements

On-board voltage

+3.3 V (3.0 A); +12 V (1.9 A)

Auxiliary voltage[2]

+12 V (1.2 A)

Power Over Camera Link (PoCL)

Powered connectors

2

Voltage

12 V, nominal

Power output

4 W, maximum (per connector)

SafePower

Supported

Physical Characteristics

Printed Circuit Board (PCB) dimensions

16.8 cm × 11.2 cm (6.6 in. × 4.4 in.)

Weight

180 g (6.35 oz)

Environment

The NI PCIe-1477 is intended for indoor use only.
Note Clean the device with a soft, non-metallic brush. Make sure the device is completely dry and free from contaminants before returning it to service.

Operating Environment

Operating temperature, local

0 °C to 55 °C

(IEC 60068-2-1 and IEC 60068-2-2)

Operating humidity

10% to 90% RH, noncondensing

(IEC 60068-2-78)

Storage Environment

Ambient temperature range

-20 °C to 70 °C

(IEC 60068-2-1 and IEC 60068-2-2)

Relative humidity range

5% to 95% RH, noncondensing

(IEC 60068-2-78)

Safety Compliance Standards

This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:

  • IEC 61010-1, EN 61010-1
  • UL 61010-1, CSA C22.2 No. 61010-1
Note For safety certifications, refer to the product label or the Product Certifications and Declarations section.

Electromagnetic Compatibility Standards

This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:

  • EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
  • EN 55011 (CISPR 11): Group 1, Class A emissions
  • AS/NZS CISPR 11: Group 1, Class A emissions
  • FCC 47 CFR Part 15B: Class A emissions
  • ICES-001: Class A emissions
Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes.
Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intended for use only in heavy-industrial locations.

CE Compliance 1378

This product meets the essential requirements of applicable European Directives, as follows:

  • 2014/35/EU; Low-Voltage Directive (safety)
  • 2014/30/EU; Electromagnetic Compatibility Directive (EMC)
  • 2011/65/EU; Restriction of Hazardous Substances (RoHS)
  • 2014/53/EU; Radio Equipment Directive (RED)
  • 2014/34/EU; Potentially Explosive Atmospheres (ATEX)

Product Certifications and Declarations

Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.

Environmental Management

NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.

For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.

EU and UK Customers

  • 1378 Waste Electrical and Electronic Equipment (WEEE)—At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee.
  • 电子信息产品污染控制管理办法(中国RoHS)

  • 1378 中国RoHSNI符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于NI中国RoHS合规性信息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)
  • NI Services

    Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples.

    Visit ni.com/services to learn about NI service offerings such as calibration options, repair, and replacement.

    Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI.

    NI corporate headquarters is located at 11500 N Mopac Expwy, Austin, TX, 78759-3504, USA.

    1 This value corresponds to the serialized Camera Link cable transmission rate of 140 to 595 MHz.

    2 Sourced from ATX 12 V power supply.

    3 For PCI Express adapter cards with integrated air movers, NI defines the local operational ambient environment to be at the fan inlet. For cards without integrated air movers, NI defines the local operational ambient environment to be 25 mm (1 in.) upstream of the leading edge of the card. For more information about the local operational ambient environment definition for PCI Express adapter cards, visit ni.com/info and enter the Info Code pcielocalambient.