FD-11637 Signal Conditioning
- Updated2024-10-22
- 1 minute(s) read
FD-11637 Signal Conditioning
Learn about excitation, quarter-bridge completion, and shunt calibration for the FD-11637.
Excitation
The FD-11637 supports internal excitation at 3 V, 5 V, and 10 V. 10 V excitation is only supported in Full-Bridge and Half-Bridge modes.
Quarter-Bridge Completion
The FD-11637 supports internal quarter-bridge completion with resistances of 120 Ω and 350 Ω.
Shunt Calibration
The FD-11637 has a built-in resistor for shunt calibration. Shunt calibration also only works in Quarter-Bridge mode.