NI-DAQmx Properties

Content Type
Programming Language
Current manual

More:Master Timebase:Source Property

Short Name: MasterTimebase.Src

Property of DAQmx Timing

Specifies the terminal of the signal to use as the Master Timebase. On an E Series device, you can choose only between the onboard 20MHz Timebase or the RTSI7 terminal.

Remarks

The following table lists the characteristics of this property.

Permissionsread/write
Resettableyes
Settable while task is runningdevice-specific
Available in Run-Time Engineyes
In This Section
Was this information helpful?

Previous

Rate

Next

Rate

Previous

Rate

Next

Rate

Log in to get a better experience