Reads samples from the task or virtual channels you specify. The instances of this polymorphic VI specify what format of samples to return, whether to read a single sample or multiple samples at once, and whether to read from one or multiple channels.
The DAQmx Read properties include additional configuration options for read operations.
Analog DBL 1Chan 1Samp
Reads a single floating-point sample from a task that contains a single analog input channel.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a sample. NI-DAQmx scales the data to the units of the measurement, including any custom scaling you apply to the channels. Use the DAQmx Create Virtual Channel VI or the DAQ Assistant to specify these units. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Analog Wfm 1Chan 1Samp
Reads a waveform that contains a single sample from a task that contains a single analog input channel.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a waveform. NI-DAQmx scales the data to the units of the measurement, including any custom scaling you apply to the channels. Use the DAQmx Create Virtual Channel VI or the DAQ Assistant to specify these units. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Analog 1D DBL 1Chan NSamp
Reads one or more floating-point samples from a task that contains a single analog input channel.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of samples. Each element in the array corresponds to a sample from the channel. NI-DAQmx scales the data to the units of the measurement, including any custom scaling you apply to the channels. Use the DAQmx Create Virtual Channel VI or the DAQ Assistant to specify these units. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Analog Wfm 1Chan NSamp
Reads a waveform from a task that contains a single analog input channel.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a waveform. NI-DAQmx scales the data to the units of the measurement, including any custom scaling you apply to the channels. Use the DAQmx Create Virtual Channel VI or the DAQ Assistant to specify these units. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Analog 1D DBL NChan 1Samp
Reads a single floating-point sample from each channel in a task that contains one or more analog input channels.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of samples. Each element of the array corresponds to a channel in the task. The order of the channels in the array corresponds to the order in which you add the channels to the task or to the order of the channels you specify with the Channels to Read property. NI-DAQmx scales the data to the units of the measurement, including any custom scaling you apply to the channels. Use the DAQmx Create Virtual Channel VI or the DAQ Assistant to specify these units. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Analog 1D Wfm NChan 1Samp
Reads a waveform that contains a single sample from each channel in a task that contains one or more analog input channels.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of waveforms. Each element of the array corresponds to a channel in the task. The order of the channels in the array corresponds to the order in which you add the channels to the task or to the order of the channels you specify with the Channels to Read property. NI-DAQmx scales the data to the units of the measurement, including any custom scaling you apply to the channels. Use the DAQmx Create Virtual Channel VI or the DAQ Assistant to specify these units. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Analog 2D DBL NChan NSamp
Reads one or more floating-point samples from a task that contains one or more analog input channels.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 2D array of samples. Each row corresponds to a channel in the task. Each column corresponds to a sample from each channel. The order of the channels in the array corresponds to the order in which you add the channels to the task or to the order of the channels you specify with the Channels to Read property. NI-DAQmx scales the data to the units of the measurement, including any custom scaling you apply to the channels. Use the DAQmx Create Virtual Channel VI or the DAQ Assistant to specify these units. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Analog 1D Wfm NChan NSamp
Reads one or more waveforms from a task that contains one or more analog input channels.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of waveforms. Each element of the array corresponds to a channel in the task. The order of the channels in the array corresponds to the order in which you add the channels to the task or to the order of the channels you specify with the Channels to Read property. NI-DAQmx scales the data to the units of the measurement, including any custom scaling you apply to the channels. Use the DAQmx Create Virtual Channel VI or the DAQ Assistant to specify these units. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Analog 2D I16 NChan NSamp
Reads one or more unscaled 16-bit signed integer samples from a task that contains one or more analog input channels.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 2D array of 16-bit signed integer samples. Each row corresponds to a channel in the task. Each column corresponds to a sample from that channel. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Analog 2D I32 NChan NSamp
Reads one or more unscaled 32-bit signed integer samples from a task that contains one or more analog input channels.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 2D array of 32-bit signed integer samples. Each row corresponds to a channel in the task. Each column corresponds to a sample from that channel. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Analog 2D U16 NChan NSamp
Reads one or more unscaled 16-bit unsigned integer samples from a task that contains one or more analog input channels.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 2D array of 16-bit unsigned integer samples. Each row corresponds to a channel in the task. Each column corresponds to a sample from that channel. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Analog 2D U32 NChan NSamp
Reads one or more unscaled 32-bit unsigned integer samples from a task that contains one or more analog input channels.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 2D array of 32-bit unsigned integer samples. Each row corresponds to a channel in the task. Each column corresponds to a sample from that channel. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital Bool 1Line 1Point
Reads a single Boolean sample from a task that contains a digital input channel composed of a single line.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a Boolean sample. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital 1D Bool 1Chan 1Samp
Reads an array of Boolean values from a task that contains a single digital input channel.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of Boolean samples. Each element of the array corresponds to a digital line in the channel. The order of the lines in the array corresponds to the order in which you add the lines to the channel. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital U8 1Chan 1Samp
Reads a single 8-bit unsigned integer sample from a task that contains a single digital input channel. Use an instance that reads 8-bit unsigned integers for devices with up to eight lines per port.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns an 8-bit unsigned integer sample. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital U16 1Chan 1Samp
Reads a single 16-bit unsigned integer sample from a task that contains a single digital input channel. Use an instance that reads 16-bit unsigned integers for devices with up to 16 lines per port.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 16-bit unsigned integer sample. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital U32 1Chan 1Samp
Reads a single 32-bit unsigned integer sample from a task that contains a single digital input channel. Use an instance that reads 32-bit unsigned integers for devices with up to 32 lines per port.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 32-bit unsigned integer sample. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital Wfm 1Chan 1Samp
Reads a digital waveform that contains a single sample from a task that contains a single digital input channel.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a digital waveform. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital 1D U8 1Chan NSamp
Reads one or more 8-bit unsigned integer samples from a task that contains a single digital input channel. Use an instance that reads 8-bit unsigned integers for devices with up to eight lines per port.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of 8-bit unsigned integer samples. Each element in the array corresponds to a sample from the task. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital 1D U16 1Chan NSamp
Reads one or more 16-bit unsigned integer samples from a task that contains a single digital input channel. Use an instance that reads 16-bit unsigned integers for devices with up to 16 lines per port.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of 16-bit unsigned integer samples. Each element in the array corresponds to a sample from the task. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital 1D U32 1Chan NSamp
Reads one or more 32-bit unsigned integer samples from a task that contains a single digital input channel. Use an instance that reads 32-bit unsigned integers for devices with up to 32 lines per port.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of 32-bit unsigned integer samples. Each element in the array corresponds to a sample from the task. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital Wfm 1Chan NSamp
Reads a digital waveform from a task that contains a single digital input channel.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a digital waveform. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital 1D Bool NChan 1Samp
Reads a single Boolean sample from each channel in a task that contains one or more digital input channels. Each channel must contain only a single digital line.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of Boolean samples. Each element of the array corresponds to a channel in the task. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital 2D Bool NChan 1Samp
Reads a single sample that contains Boolean values from each channel in a task that contains one or more digital input channels. Each channel can contain multiple digital lines.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 2D array of Boolean samples. Each row corresponds to a channel in the task. Each column corresponds to a line in that channel. The order of the channels in the array corresponds to the order that you add the channels to the task or to the order of the channels you specify in the Channels to Read property. The order of the lines in each channel corresponds to the order that you add the lines to the channel. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital 1D U8 NChan 1Samp
Reads a single 8-bit unsigned integer sample from each channel in a task that contains one or more digital input channels. Use an instance that reads 8-bit unsigned integers for devices with up to eight lines per port.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of 8-bit unsigned integer samples. Each element in the array corresponds to a channel in the task. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital 1D U16 NChan 1Samp
Reads a single 16-bit unsigned integer sample from each channel in a task that contains one or more digital input channels. Use an instance that reads 16-bit unsigned integers for devices with up to 16 lines per port.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of 16-bit unsigned integer samples. Each element in the array corresponds to a channel in the task. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital 1D U32 NChan 1Samp
Reads a single 32-bit unsigned integer sample from each channel in a task that contains one or more digital input channels. Use an instance that reads 32-bit unsigned integers for devices with up to 32 lines per port.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of 32-bit unsigned integer samples. Each element in the array corresponds to a channel in the task. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital 1D Wfm NChan 1Samp
Reads a waveform that contains a single sample from each channel in a task that contains one or more digital input channels.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of digital waveforms that each contain a single sample. Each element in the array corresponds to a channel in the task. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital 2D U8 NChan NSamp
Reads one or more 8-bit unsigned integer samples from a task that contains one or more digital input channels. Use an instance that reads 8-bit unsigned integers for devices with up to eight lines per port.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 2D array of 8-bit unsigned integer samples. Each row corresponds to a channel in the task. Each column corresponds to a sample from each channel. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital 2D U16 NChan NSamp
Reads one or more 16-bit unsigned integer samples from a task that contains one or more digital input channels. Use an instance that reads 16-bit unsigned integers for devices with up to 16 lines per port.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 2D array of 16-bit unsigned integer samples. Each row corresponds to a channel in the task. Each column corresponds to a sample from each channel. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital 2D U32 NChan NSamp
Reads one or more 32-bit unsigned integer samples from a task that contains one or more digital input channels. Use an instance that reads 32-bit unsigned integers for devices with up to 32 lines per port.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 2D array of 32-bit unsigned integer samples. Each row corresponds to a channel in the task. Each column corresponds to a sample from each channel. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Digital 1D Wfm NChan NSamp
Reads one or more digital waveforms from a task that contains one or more digital input channels.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of digital waveforms. Each element in the array corresponds to a channel in the task. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Counter DBL 1Samp
Reads a single floating-point sample from a counter task. Use an instance that reads floating-point values when NI-DAQmx scales counter samples to a floating-point value, such as for frequency and period measurement.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a sample. NI-DAQmx scales the data to the units of the measurement, including any custom scaling you apply to the channels. Use the DAQmx Create Virtual Channel VI or the DAQ Assistant to specify these units. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Counter U32 1Samp
Reads a 32-bit unsigned integer sample from a counter task. Use an instance that reads 32-bit unsigned integers when NI-DAQmx returns counter samples unscaled, such as for event counting.
If the sample unit of your task cannot be represented by an integer, data is returned in the unit of clock ticks.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a sample. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Counter Freq 1Samp
Reads a single pair of pulse frequency and duty cycle from a counter input task.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
frequency is the pulse frequency. |
||||||
![]() |
duty cycle is the pulse high time divided by the pulse period. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Counter Time 1Samp
Reads a single pair of pulse high and low times from a counter input task.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
high time is the amount of time the pulse is high. |
||||||
![]() |
low time is the amount of time the pulse is low. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Counter Ticks 1Samp
Reads a single pair of pulse high and low tick counts from a counter input task.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
high ticks is the number of ticks the pulse is high. |
||||||
![]() |
low ticks is the number of ticks the pulse is low. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Counter 1D DBL 1Chan NSamp
Reads one or more floating-point samples from a counter task. Use an instance that reads a floating-point value when NI-DAQmx scales counter samples to a floating-point value, such as for frequency and period measurement.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of samples. Each element in the array corresponds to a sample from the channel. NI-DAQmx scales the data to the units of the measurement, including any custom scaling you apply to the channels. Use the DAQmx Create Virtual Channel VI or the DAQ Assistant to specify these units. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Counter 1D DBL NChan 1Samp
Reads one floating-point sample from one or more counter tasks. Use an instance that reads a floating-point value when NI-DAQmx scales counter samples to a floating-point value.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of samples. Each element of the array corresponds to a channel in the task. The order of the channels in the array corresponds to the order in which you add the channels to the task or to the order of the channels you specify with the Channels to Read property. NI-DAQmx scales the data to the units of the measurement, including any custom scaling you apply to the channels. Use the DAQmx Create Virtual Channel VI or the DAQ Assistant to specify these units. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Counter 1D U32 1Chan NSamp
Reads one or more 32-bit unsigned integer samples from a counter task. Use an instance that reads 32-bit unsigned integers when NI-DAQmx returns counter samples unscaled, such as for event counting.
If the sample unit of your task cannot be represented by an integer, data is returned in the unit of clock ticks.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns samples. Each element of the array corresponds to a sample from the task. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Counter 1D U32 NChan 1Samp
Reads an unscaled 32-bit unsigned integer sample from one or more counter tasks.
If the sample unit of your task cannot be represented by an integer, data is returned in the unit of clock ticks.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of 32-bit unsigned integer samples. Each element in the array corresponds to a channel in the task. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Counter 1D Freq NSamp
Reads one or more pairs of pulse frequency and duty cycle from a counter input task.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data contains pairs of pulse frequency and duty cycle. Each element in the array corresponds to a sample from the task.
|
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Counter 1D Time NSamp
Reads one or more pairs of pulse high and low times from a counter input task.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data contains pairs of pulse high times and low times. Each element in the array corresponds to a sample from the task.
|
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Counter 1D Ticks NSamp
Reads one or more pairs of pulse high and low tick counts from a counter input task.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data contains pairs of pulse high and low tick counts. Each element in the array corresponds to a sample from the task.
|
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Counter 2D DBL NChan NSamp
Reads one or more floating-point samples from one or more counter tasks. Use an instance that reads a floating-point value when NI-DAQmx scales counter samples to a floating-point value.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 2D array of samples. Each row corresponds to a channel in the task. Each column corresponds to a sample from each channel. The order of the channels in the array corresponds to the order in which you add the channels to the task or to the order of the channels you specify with the Channels to Read property. NI-DAQmx scales the data to the units of the measurement, including any custom scaling you apply to the channels. Use the DAQmx Create Virtual Channel VI or the DAQ Assistant to specify these units. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Counter 2D U32 NChan NSamp
Reads one or more unscaled 32-bit unsigned integer samples from one or more counter tasks.
If the sample unit of your task cannot be represented by an integer, data is returned in the unit of clock ticks.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 2D array of 32-bit unsigned integer samples. Each row corresponds to a channel in the task. Each column corresponds to a sample from each channel. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Power DBL 1Chan 1Samp
Reads one floating-point sample from a task that contains a single power channel.
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
voltage contains the read voltage value data. |
||||||
![]() |
current contains the read current value data. |
Power Wfm 1Chan 1Samp
Reads a waveform that contains a single floating-point sample from a task that contains a single power channel.
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
voltage contains the read voltage value data. |
||||||
![]() |
current contains the read current value data. |
Power 1D DBL 1Chan NSamp
Reads one or more floating-point samples from a task that contains a single power channel.
![]() |
number of samples per channel specifies the number of samples to read. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
voltage contains the read voltage value data. |
||||||
![]() |
current contains the read current value data. |
Power Wfm 1Chan NSamp
Reads a waveform that contains one or more floating-point samples from a task that contains a single power channel.
![]() |
number of samples per channel specifies the number of samples to read. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
voltage contains the read voltage value data. |
||||||
![]() |
current contains the read current value data. |
Power 1D DBL NChan 1Samp
Reads one floating-point sample from a task that contains one or more power channels.
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
voltage contains the read voltage value data. |
||||||
![]() |
current contains the read current value data. |
Power 1D Wfm NChan 1Samp
Reads a waveform that contains a single floating-point sample from each channel in a task that contains one or more power channels.
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
voltage contains the read voltage value data. |
||||||
![]() |
current contains the read current value data. |
Power 2D DBL NChan NSamp
Reads one or more floating-point samples from a task that contains one or more power channel.
![]() |
number of samples per channel specifies the number of samples to read. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
voltage contains the read voltage value data. |
||||||
![]() |
current contains the read current value data. |
Power 1D Wfm NChan NSamp
Reads one or more waveforms that contains one or more floating-point samples from a task that contains one or more power channels.
![]() |
number of samples per channel specifies the number of samples to read. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
voltage contains the read voltage value data. |
||||||
![]() |
current contains the read current value data. |
Power 2D I16 NChan NSamp
Reads one or more unscaled 16-bit signed integer samples from a task that contains one or more power channels.
![]() |
number of samples per channel specifies the number of samples to read. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
voltage contains the read voltage value data. |
||||||
![]() |
current contains the read current value data. |
Raw 1D U8
Reads one or more raw, 8-bit unsigned integer samples from a task. Use this instance with devices that use 8-bit unsigned integers as the internal representation of a sample.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of raw 8-bit unsigned integer samples. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Raw 1D U16
Reads one or more raw, 16-bit unsigned integer samples from a task. Use this instance with devices that use 16-bit unsigned integers as the internal representation of a sample.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of raw 16-bit unsigned integer samples. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Raw 1D U32
Reads one or more raw, 32-bit unsigned integer samples from a task. Use this instance with devices that use 32-bit unsigned integers as the internal representation of a sample.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of raw 32-bit unsigned integer samples. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Raw 1D I8
Reads one or more raw, 8-bit signed integer samples from a task. Use this instance with devices that use 8-bit signed integers as the internal representation of a sample.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of raw 8-bit signed integer samples. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Raw 1D I16
Reads one or more raw, 16-bit signed integer samples from a task. Use this instance with devices that use 16-bit signed integers as the internal representation of a sample.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of raw 16-bit signed integer samples. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
Raw 1D I32
Reads one or more raw, 32-bit signed integer samples from a task. Use this instance with devices that use 32-bit signed integers as the internal representation of a sample.
![]() |
task/channels in is the name of the task or a list of virtual channels to which the operation applies. If you provide a list of virtual channels, NI-DAQmx creates a task automatically. |
||||||
![]() |
number of samples per channel specifies the number of samples to read. If you leave this input unwired or set it to -1, NI-DAQmx determines how many samples to read based on if the task acquires samples continuously or acquires a finite number of samples. If the task acquires samples continuously and you set this input to -1, this VI reads all the samples currently available in the buffer. If the task acquires a finite number of samples and you set this input to -1, the VI waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the VI reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples. |
||||||
![]() |
timeout specifies the amount of time in seconds to wait for samples to become available. If the time elapses, the VI returns an error and any samples read before the timeout elapsed. The default timeout is 10 seconds. If you set timeout to -1, the VI waits indefinitely. If you set timeout to 0, the VI tries once to read the requested samples and returns an error if it is unable to. |
||||||
![]() |
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
||||||
![]() |
task out is a reference to the task after this VI or function runs. If you wired a channel or list of channels to task/channels in, NI-DAQmx creates this task automatically. |
||||||
![]() |
data returns a 1D array of raw 32-bit signed integer samples. |
||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|
In This Section
- Analog DBL 1Chan 1Samp
- Analog Wfm 1Chan 1Samp
- Analog 1D DBL 1Chan NSamp
- Analog Wfm 1Chan NSamp
- Analog 1D DBL NChan 1Samp
- Analog 1D Wfm NChan 1Samp
- Analog 2D DBL NChan NSamp
- Analog 1D Wfm NChan NSamp
- Analog 2D I16 NChan NSamp
- Analog 2D I32 NChan NSamp
- Analog 2D U16 NChan NSamp
- Analog 2D U32 NChan NSamp
- Digital Bool 1Line 1Point
- Digital 1D Bool 1Chan 1Samp
- Digital U8 1Chan 1Samp
- Digital U16 1Chan 1Samp
- Digital U32 1Chan 1Samp
- Digital Wfm 1Chan 1Samp
- Digital 1D U8 1Chan NSamp
- Digital 1D U16 1Chan NSamp
- Digital 1D U32 1Chan NSamp
- Digital Wfm 1Chan NSamp
- Digital 1D Bool NChan 1Samp
- Digital 2D Bool NChan 1Samp
- Digital 1D U8 NChan 1Samp
- Digital 1D U16 NChan 1Samp
- Digital 1D U32 NChan 1Samp
- Digital 1D Wfm NChan 1Samp
- Digital 2D U8 NChan NSamp
- Digital 2D U16 NChan NSamp
- Digital 2D U32 NChan NSamp
- Digital 1D Wfm NChan NSamp
- Counter DBL 1Samp
- Counter U32 1Samp
- Counter Freq 1Samp
- Counter Time 1Samp
- Counter Ticks 1Samp
- Counter 1D DBL 1Chan NSamp
- Counter 1D DBL NChan 1Samp
- Counter 1D U32 1Chan NSamp
- Counter 1D U32 NChan 1Samp
- Counter 1D Freq NSamp
- Counter 1D Time NSamp
- Counter 1D Ticks NSamp
- Counter 2D DBL NChan NSamp
- Counter 2D U32 NChan NSamp
- Power DBL 1Chan 1Samp
- Power Wfm 1Chan 1Samp
- Power 1D DBL 1Chan NSamp
- Power Wfm 1Chan NSamp
- Power 1D DBL NChan 1Samp
- Power 1D Wfm NChan 1Samp
- Power 2D DBL NChan NSamp
- Power 1D Wfm NChan NSamp
- Power 2D I16 NChan NSamp
- Raw 1D U8
- Raw 1D U16
- Raw 1D U32
- Raw 1D I8
- Raw 1D I16
- Raw 1D I32