NI-9866
Block Diagram
The NI-9866 has one full-featured LIN port that is isolated from the other modules in the system. The port has a LIN controller that is fully compliant with the LIN 1.3/2.0/2.1/2.2 Specification. The port also has an NXP TJA1028 LIN transceiver that is fully compatible with the LIN 1.3/2.0/2.1/2.2 and SAE J2602 standard and supports baud rates up to 20 kbps.
NI-9866
Pinout
Connector | Pin | Signal Name |
---|---|---|
![]() |
1 | No Connection (NC) |
2 | NC | |
3 | COM | |
4 | NC | |
5 | SHLD | |
6 | COM | |
7 | LIN | |
8 | NC | |
9 | Vsup |
The NI-9866 has one 9-pin male D-Sub connector that provides connections to a LIN bus.
The port has two common pins (COM) that are internally connected to the module’s isolated reference and serve as the reference ground for LIN signal. You can connect the LIN bus reference ground to one or both COM pins. The port also has an optional shield pin, SHLD, that you can connect to a shielded LIN cable. Connecting SHLD may improve signal integrity and EMC performance in a noisy environment.
The NI-9866 requires an external power supply of +8 V to +18 V to operate. Supply power to the NI-9866 Vsup pin from the LIN bus.
Cabling Requirements for the NI-9866
This section deals with cabling specifications, termination resistors, cable lengths, and the number of LIN nodes that can exist in a system.
Cable Specifications
Cable Lengths
The maximum allowable cable length is 40 m, per the LIN specification.
Number of LIN Devices
The maximum number of devices on a LIN bus is 16, per the LIN specification.
Termination Resistors
LIN cables require no termination, as nodes are terminated at the transceiver. Slave nodes typically are pulled up from the LIN bus to VBat with a 30 kΩ resistance and a serial diode. This termination usually is integrated into the transceiver package. The master node requires a 1 kΩ resistor and serial diode between the LIN bus and VBat. On NI-XNET LIN products, master termination is software selectable; you can enable it in the API with the NI-XNET Session Interface:LIN:Termination property.