NI-9477 Specifications
- Updated2024-11-25
- 4 minute(s) read
NI-9477 Specifications
Definitions
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
- Typical specifications describe the performance met by a majority of models.
- Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.
Specifications are Typical unless otherwise noted.
Conditions
Specifications are valid for the range -40 °C to 70 °C unless otherwise noted. All voltages are relative to COM unless otherwise noted.
NI-9477 Pinout
Signal | Description |
---|---|
COM | Common reference connection |
DO | Digital output signal connection |
NC | No connection |
Output Characteristics
Number of channels | 32 digital output channels | ||||||
Output type | Sinking | ||||||
Power-on output state | Channels off[1]1 The module may experience a 3 ms to 4 ms glitch on the output during a chassis power cycle or software reset. | ||||||
Output voltage (V0) | I0 · R0 | ||||||
External power supply voltage range | 0 V DC to 60 V DC | ||||||
| |||||||
Output impedance (R0) | 0.065 Ω maximum | ||||||
Reversed-voltage protection | None | ||||||
Short-circuit protection | None | ||||||
Maximum update rate | 8 μs maximum | ||||||
Propagation delay | 1 μs maximum | ||||||
MTBF | 717,920 hours at 25 °C; Bellcore Issue 2, Method 1, Case 3, Limited Part Stress Method |
Environmental Characteristics
| |||||||||||||
| |||||||||||||
Ingress protection | IP40 | ||||||||||||
Pollution Degree | 2 | ||||||||||||
Maximum altitude | 2,000 m | ||||||||||||
|
To meet these shock and vibration specifications, you must panel mount the system.
Safety Voltages
Connect only voltages that are within the following limits:
Channel-to-COM[2]2 The maximum voltage that can be applied or output between a channel and COM without creating a safety hazard. | 60 V DC maximum, Measurement Category I | ||||||||||||
|
Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
Power Requirements
| |||||||
|
Physical Characteristics
Dimensions | Visit ni.com/dimensions and search by module number. |
Weight | 145 g (5.1 oz) |