NI-9421 Specifications
- Updated2024-11-25
- 6 minute(s) read
NI-9421 Specifications
Connector Types
The NI-9421 has more than one connector type: NI-9421 with screw terminal, NI-9421 with spring terminal, and NI-9421 with DSUB. Unless the connector type is specified, NI-9421 refers to all connector types.
Definitions
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
- Typical specifications describe the performance met by a majority of models.
- Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.
Specifications are Typical unless otherwise noted.
Conditions
Specifications are valid for the range -40 °C to 70 °C unless otherwise noted.
NI 9421 with DSUB Pinout
Signal | Description |
---|---|
COM | Common reference connection to isolated ground |
DI | Digital input signal connection |
NC | No connection |
LED Pattern | Indication |
---|---|
Solid | The channel has been programmed to be in the ON state. |
Off | The channel has been programmed to be in the OFF state. |
NI 9421 with Screw Terminal or Spring Terminal Pinout
Signal | Description |
---|---|
COM | Common reference connection to isolated ground |
DI | Digital input signal connection |
NC | No connection |
LED Pattern | Indication |
---|---|
Solid | The channel has been programmed to be in the ON state. |
Off | The channel has been programmed to be in the OFF state. |
Input Characteristics
Number of channels | 8 digital input channels | ||||||||||||||||||
Input type | Sinking | ||||||||||||||||||
| |||||||||||||||||||
| |||||||||||||||||||
Input delay time | 100 μs maximum | ||||||||||||||||||
MTBF | 2,086,204 hours at 25 °C; Bellcore Issue 2, Method I, Case 3, Limited Part Stress Method |
Power Requirements
| |||||||
|
Physical Characteristics
Weight
NI-9421 with screw terminal | 166 g (5.9 oz) |
NI-9421 with spring terminal | 153 g (5.4 oz) |
NI-9421 with DSUB | 144 g (5.0 oz) |
NI-9421 with Screw
Terminal Wiring
Gauge | 0.2 mm2 to 2.5 mm2 (26 AWG to 14 AWG) copper conductor wire |
Wire strip length | 13 mm (0.51 in.) of insulation stripped from the end |
Temperature rating | 90 °C minimum |
Torque for screw terminals | 0.5 N · m to 0.6 N · m(4.4 lb · in. to 5.3 lb · in.) |
Wires per screw terminal | One wire per screw terminal; two wires per screw terminal using a 2-wire ferrule |
NI-9421 with Spring
Terminal Wiring
Gauge | 0.2 mm2 to 2.5 mm2 (30 AWG to 12 AWG) copper conductor wire |
Wire strip length | 10 mm (0.39 in.) of insulation stripped from the end |
Temperature rating | 90 °C minimum |
Wires per spring terminal | One wire per spring terminal; two wires per spring terminal using a 2-wire ferrule |
NI-9421 with Screw
Terminal and NI-9421 with Spring Terminal Connector
Securement
Securement type | Screw flanges provided |
Torque for screw flanges | 0.2 N · m (1.80 lb · in.) |
NI-9421 with Screw Terminal and NI-9421 with Spring Terminal Safety Voltages
Connect only voltages that are within the following limits:
Channel-to-COM | 30 V maximum | ||||||||||||
Overvoltage protection | 40 V maximum | ||||||||||||
Reverse-biased voltage | -30 V maximum | ||||||||||||
|
NI-9421 with
DSUB Safety Voltages
Connect only voltages that are within the following limits:
Channel-to-COM | 30 V maximum | ||||||||||||
Overvoltage protection | 40 V maximum | ||||||||||||
Reverse-biased voltage | -30 V maximum | ||||||||||||
|
Measurement Categories
Measurement Category I
Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
Measurement Category II
Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe.
Environmental Characteristics
| |||||||||||||
| |||||||||||||
Ingress protection | IP40 | ||||||||||||
Pollution Degree | 2 | ||||||||||||
Maximum altitude | 2,000 m | ||||||||||||
|
To meet these shock and vibration specifications, you must panel mount the system.
In This Section
- Connector Types
- Definitions
- Conditions
- NI 9421 with DSUB Pinout
- NI 9421 with Screw Terminal or Spring Terminal Pinout
- Input Characteristics
- Power Requirements
- Physical Characteristics
- NI-9421 with Screw Terminal and NI-9421 with Spring Terminal Safety Voltages
- NI-9421 with
DSUB Safety Voltages
- Measurement Categories
- Environmental Characteristics