NI-9403 Specifications
- Updated2024-11-05
- 5 minute(s) read
NI-9403 Specifications
Definitions
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
- Typical specifications describe the performance met by a majority of models.
- Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.
Specifications are Typical unless otherwise noted.
Conditions
Specifications are valid for the range -40 °C to 70 °C unless otherwise noted. All voltages are relative to COM unless otherwise noted.
NI 9403 Pinout
Signal | Description |
---|---|
COM | Common reference connection to isolated ground |
DIO | Digital input/output signal connection |
RSVD | Reserved, no connection |
Input/Output Characteristics
Number of channels | 32 digital input/output channels | ||||||||||||||||||||||||||||
Input/output type | TTL, single-ended | ||||||||||||||||||||||||||||
Default power-on line direction | Input | ||||||||||||||||||||||||||||
Input Current (0 V ≤ Vin ≤ 4.5 V) | ±250 µA maximum | ||||||||||||||||||||||||||||
Module output current[1]1 Module output current is the maximum guaranteed current that the module can drive from all the I/O lines without going into an overcurrent state. | 64 mA maximum | ||||||||||||||||||||||||||||
Input capacitance | 30 pF | ||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||
Overvoltage protection Channel-to-COM | ±30 V maximum on up to 8 channels at a time; however, continued use at this level will degrade the life of the module. | ||||||||||||||||||||||||||||
MTBF | 763,325 hours at 25 °C; Bellcore Issue 2, Method 1, Case 3, Limited Part Stress Method |
Digital Logic Levels
| |||||||||||||||||||
|
Power Requirements
| |||||||
|
Physical Characteristics
Dimensions | Visit ni.com/dimensions and search by module number. |
Weight | 150 g (5.3 oz) |
Safety Voltages
Connect only voltages that are within the following limits:
Channel-to-COM | ±30 V maximum on up to 8 channels at a time, Measurement Category I | ||||||||||||||||||
|
Measurement Category I
Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
Environmental Characteristics
| |||||||||||||
| |||||||||||||
Ingress protection | IP40 | ||||||||||||
Pollution Degree | 2 | ||||||||||||
Maximum altitude | 5,000 m | ||||||||||||
|
To meet these shock and vibration specifications, you must panel mount the system.
1 Module output current is the maximum guaranteed current that the module can drive from all the I/O lines without going into an overcurrent state.
2 Setup time is the amount of time input signals must be stable before reading from the module.
3 Hold time is the amount of time input signals must be stable after initiating a read from the module.
4 Propagation delay is the amount of time after writing to the module that the output signals become valid.
5 Channel-to-channel skew is the amount of time between the first output signal updating and the last output signal updating.
6 The update/transfer and direction change times are valid when the module is used in a CompactRIO system. When used in other systems, driver software and system latencies impact these times.