NI-9403 Specifications

Definitions

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.

  • Typical specifications describe the performance met by a majority of models.
  • Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.

Specifications are Typical unless otherwise noted.

Conditions

Specifications are valid for the range -40 °C to 70 °C unless otherwise noted. All voltages are relative to COM unless otherwise noted.

NI 9403 Pinout



Table 1. Signal Descriptions
Signal Description
COM Common reference connection to isolated ground
DIO Digital input/output signal connection
RSVD Reserved, no connection

Input/Output Characteristics

Number of channels

32 digital input/output channels

Input/output type

TTL, single-ended

Default power-on line direction

Input

Input Current (0 V ≤ Vin4.5 V)

±250 µA maximum

Module output current[1]1 Module output current is the maximum guaranteed current that the module can drive from all the I/O lines without going into an overcurrent state.

64 mA maximum

Input capacitance

30 pF

Timing
Input

Setup time[2]2 Setup time is the amount of time input signals must be stable before reading from the module.

10 ns minimum

Hold time[3]3 Hold time is the amount of time input signals must be stable after initiating a read from the module.

60 ns minimum

Output

Propagation delay[4]4 Propagation delay is the amount of time after writing to the module that the output signals become valid.

330 ns maximum

Channel-to-channel skew[5]5 Channel-to-channel skew is the amount of time between the first output signal updating and the last output signal updating.

265 ns maximum

Update/transfer time[6]6 The update/transfer and direction change times are valid when the module is used in a CompactRIO system. When used in other systems, driver software and system latencies impact these times.

cRIO-9151 R Series Expansion chassis

8 µS maximum

All other chassis

7 µS maximum

Direction change time

18 µS maximum

Overvoltage protection Channel-to-COM

±30 V maximum on up to 8 channels at a time; however, continued use at this level will degrade the life of the module.

MTBF

763,325 hours at 25 °C; Bellcore Issue 2, Method 1, Case 3, Limited Part Stress Method

Digital Logic Levels

Input

Voltage

-0.25 V to 5.25 V

High, VIH

2.2 V minimum

Low, VIL

0.8 V maximum

Hysteresis, VH

0.2 V minimum

Output
High, VOH (5.2 V maximum)

Sourcing 100 µA

4.75 V minimum

Sourcing 2 mA

4.4 V minimum

Low, VOL

Sinking 100 µA

0.1 V maximum

Sinking 2 mA

0.26 V maximum

Power Requirements

Power consumption from chassis

Active mode

1 W maximum

Sleep mode

25 µW maximum

Thermal dissipation (at 70 °C)

Active mode

1 W maximum

Sleep mode

25 µW maximum

Physical Characteristics

Dimensions

Visit ni.com/dimensions and search by module number.

Weight

150 g (5.3 oz)

Safety Voltages

Connect only voltages that are within the following limits:

Channel-to-COM

±30 V maximum on up to 8 channels at a time, Measurement Category I

Isolation

Channel-to-channel

None

Channel-to-earth ground

Continuous

60 V DC, Measurement Category I

Withstand

Up to 3,000 m altitude

1,000 V RMS, verified by a 5 s dielectric withstand test

Up to 5,000 m altitude

860 V RMS, verified by a 5 s dielectric withstand test

Measurement Category I

Warning Do not connect the product to signals or use for measurements within Measurement Categories II, III, or IV, or for measurements on MAINs circuits or on circuits derived from Overvoltage Category II, III, or IV which may have transient overvoltages above what the product can withstand. The product must not be connected to circuits that have a maximum voltage above the continuous working voltage, relative to earth or to other channels, or this could damage and defeat the insulation. The product can only withstand transients up to the transient overvoltage rating without breakdown or damage to the insulation. An analysis of the working voltages, loop impedances, temporary overvoltages, and transient overvoltages in the system must be conducted prior to making measurements.
Mise en garde Ne pas connecter le produit à des signaux dans les catégories de mesure II, III ou IV et ne pas l'utiliser pour des mesures dans ces catégories, ou des mesures sur secteur ou sur des circuits dérivés de surtensions de catégorie II, III ou IV pouvant présenter des surtensions transitoires supérieures à ce que le produit peut supporter. Le produit ne doit pas être raccordé à des circuits ayant une tension maximale supérieure à la tension de fonctionnement continu, par rapport à la terre ou à d'autres voies, sous peine d'endommager et de compromettre l'isolation. Le produit peut tomber en panne et son isolation risque d'être endommagée si les tensions transitoires dépassent la surtension transitoire nominale. Une analyse des tensions de fonctionnement, des impédances de boucle, des surtensions temporaires et des surtensions transitoires dans le système doit être effectuée avant de procéder à des mesures.

Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.

Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are for other circuits not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV.

Environmental Characteristics

Temperature

Operating

-40 °C to 70 °C

Storage

-40 °C to 85 °C

Humidity

Operating

10% RH to 90% RH, noncondensing

Storage

5% RH to 95% RH, noncondensing

Ingress protection

IP40

Pollution Degree

2

Maximum altitude

5,000 m

Shock and Vibration
Operating vibration

Random

5 g RMS, 10 Hz to 500 Hz

Sinusoidal

5 g, 10 Hz to 500 Hz

Operating shock

30 g, 11 ms half sine; 50 g, 3 ms half sine; 18 shocks at 6 orientations

To meet these shock and vibration specifications, you must panel mount the system.

1 Module output current is the maximum guaranteed current that the module can drive from all the I/O lines without going into an overcurrent state.

2 Setup time is the amount of time input signals must be stable before reading from the module.

3 Hold time is the amount of time input signals must be stable after initiating a read from the module.

4 Propagation delay is the amount of time after writing to the module that the output signals become valid.

5 Channel-to-channel skew is the amount of time between the first output signal updating and the last output signal updating.

6 The update/transfer and direction change times are valid when the module is used in a CompactRIO system. When used in other systems, driver software and system latencies impact these times.