NI-9228 Specifications

Definitions

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.

  • Typical specifications describe the performance met by a majority of models.
  • Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.

Specifications are Typical unless otherwise noted.

Conditions

Specifications are valid for the range -40 °C to 70 °C unless otherwise noted. All voltages are relative to the AI- signal on each channel unless otherwise noted.

NI-9228 Pinout



Table 1. Signal Descriptions
Signal Description
AI+ Positive analog input signal connection
AI- Negative analog input signal connection

Safety Voltages

Connect only voltages that are within the following limits:

Channel-to-channel isolation
Up to 2,000 m altitude

Continuous

250 V RMS, Measurement Category II

Withstand

1,500 V RMS, verified by a 5 s dielectric test

Up to 5,000 m altitude

Continuous

60 V DC, Measurement Category I

Withstand

1,000 V RMS, verified by a 5 s dielectric test

Division 2 and Zone 2 hazardous locations applications

60 V DC, Measurement Category I

Channel-to-earth ground isolation
Up to 2,000 m altitude

Continuous

250 V RMS, Measurement Category II

Withstand

3,000 V RMS, verified by a 5 s dielectric test

Up to 5,000 m altitude

Continuous

60 V DC, Measurement Category I

Withstand

1,000 V RMS , verified by a 5 s dielectric test

Division 2 and Zone 2 hazardous locations applications

60 V DC, Measurement Category I

Measurement Categories

Measurement Category I

Warning Do not connect the product to signals or use for measurements within Measurement Categories II, III, or IV, or for measurements on MAINs circuits or on circuits derived from Overvoltage Category II, III, or IV which may have transient overvoltages above what the product can withstand. The product must not be connected to circuits that have a maximum voltage above the continuous working voltage, relative to earth or to other channels, or this could damage and defeat the insulation. The product can only withstand transients up to the transient overvoltage rating without breakdown or damage to the insulation. An analysis of the working voltages, loop impedances, temporary overvoltages, and transient overvoltages in the system must be conducted prior to making measurements.
Mise en garde Ne pas connecter le produit à des signaux dans les catégories de mesure II, III ou IV et ne pas l'utiliser pour des mesures dans ces catégories, ou des mesures sur secteur ou sur des circuits dérivés de surtensions de catégorie II, III ou IV pouvant présenter des surtensions transitoires supérieures à ce que le produit peut supporter. Le produit ne doit pas être raccordé à des circuits ayant une tension maximale supérieure à la tension de fonctionnement continu, par rapport à la terre ou à d'autres voies, sous peine d'endommager et de compromettre l'isolation. Le produit peut tomber en panne et son isolation risque d'être endommagée si les tensions transitoires dépassent la surtension transitoire nominale. Une analyse des tensions de fonctionnement, des impédances de boucle, des surtensions temporaires et des surtensions transitoires dans le système doit être effectuée avant de procéder à des mesures.

Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.

Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are for other circuits not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV.

Measurement Category II

Caution If using in explosive atmospheres, do not connect the NI-9228 to signals or use for measurements within Measurement Categories II, III, or IV.
Attention S'il est utilisé dans des atmosphères explosibles, ne pas connecter le NI-9228 à des signaux ou l'utiliser pour effectuer des mesures dans les catégories de mesure II, III ou IV.
Caution Do not connect the product to signals or use for measurements within Measurement Categories III or IV.
Attention Ne pas connecter le produit à des signaux dans les catégories de mesure III ou IV et ne pas l'utiliser pour effectuer des mesures dans ces catégories.

Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe.

Environmental Characteristics

Temperature

Operating

-40 °C to 70 °C

Storage

-40 °C to 85 °C

Humidity

Operating

10% RH to 90% RH, noncondensing

Storage

5% RH to 95% RH, noncondensing

Ingress protection

IP40

Pollution Degree

2

Maximum altitude

5,000 m

Shock and Vibration
Operating vibration

Random

5 g RMS, 10 Hz to 500 Hz

Sinusoidal

5 g, 10 Hz to 500 Hz

Operating shock

30 g, 11 ms half sine; 50 g, 3 ms half sine; 18 shocks at 6 orientations

To meet these shock and vibration specifications, you must panel mount the system.

Power Requirements

Power consumption from chassis

Active mode

934 mW maximum

Sleep mode

53 μW maximum

Thermal dissipation

Active mode

1.43 W maximum

Sleep mode

53 μW maximum

Physical Characteristics

If you need to clean the module, wipe it with a dry towel.

Dimensions

Visit ni.com/dimensions and search by module number.

Screw-terminal wiring

Gauge

0.05 mm2 to 1.5 mm2 (30 AWG to 14 AWG) copper conductor wire

Wire strip length

6 mm (0.24 in.) of insulation stripped from the end

Temperature rating

90 °C, minimum

Torque for screw terminals

0.22 N · m to 0.25 N · m (1.95 lb · in. to 2.21 lb · in.)

Wires per screw terminal

One wire per screw terminal; two wires per screw terminal using a 2-wire ferrule

Ferrules

0.25 mm2 to 1.5 mm2

Connector securement

Securement type

Screw flanges provided

Torque for screw flanges

0.2 N · m (1.80 lb · in.)

Weight

152 g (5.36 oz)

Input Characteristics

Number of channels

8 analog input channels

ADC resolution

24 bits

Type of ADC

Delta-Sigma

Sampling mode

Simultaneous

Table 2. Conversion time (simultaneously sampled)
Timing Mode Conversion Time (ms) Sample Rate (S/s)
High resolution 500 2
Medium resolution 83.3 12
Medium speed 10 100
High speed 1 1000
Input voltage ranges, AI+ to AI-

Typical

±63.8 V

Minimum

±63.2 V

Overvoltage protection, AI+ to AI-

250 Vrms

Input coupling

DC

Figure 1. Input Bias Current


Table 3. NI-9228 Accuracy
Measurement Conditions Percent of Reading (Gain Error) Percent of Range[1]1 Range equals 63.8 V (Offset Error)
Calibrated Typical (25 °C, ±5 °C) ±0.11% ±0.02%
Maximum (-40 °C to 70 °C) ±0.40% ±0.06%
Input noise

High resolution

24 μVrms

Medium resolution

34 μVrms

Medium speed

78 μVrms

High speed

294 μVrms

Stability

Gain drift

±16 ppm/°C

Offset drift

±96 μV/°C

Post-calibration gain match (fin = 100 Hz)

±76 mdB maximum

Phase mismatch, channel-to-channel (fin = 100 Hz)

±0.002 °/Hz maximum

Input delay

High resolution

199.290 ms

Medium resolution

41.619 ms

Medium speed

3.696 ms

High speed

0.323 ms

Figure 1. Filter Frequency Response


Signal input bandwidth, -3 dB

High resolution

2.2 Hz

Medium resolution

11.8 Hz

Medium speed

115.3 Hz

High speed

1.3 kHz

Common-Mode Rejection Ratio (CMRR), rejection of channel-to-earth common-mode voltages

High resolution (fin = 50/60 Hz)

160 dB

Medium resolution (fin = 50/60 Hz)

160 dB

Medium speed (fin = 50/60 Hz)

130 dB

High speed

Refer to the following figure

Figure 1. High speed CMRR (0 Hz to 500 Hz)


Normal-Mode Rejection Ratio (NMRR)

High resolution (fin = 50 Hz ±1 Hz or 60 Hz ±1 Hz)

120 dB minimum

Medium resolution (fin = 50 Hz ±1 Hz or 60 Hz ±1 Hz)

80 dB minimum

Crosstalk (fin = 1 kHz)

-120 dB

Alias hole rejection ( (fin = 614.4 kHz)

75 dB

Calibration

You can obtain the calibration certificate and information about calibration services for the NI-9228 at ni.com/calibration.

Calibration interval

2 years

1 Range equals 63.8 V