NI-9149 Specifications
- Updated2025-07-01
- 5 minute(s) read
NI-9149 Specifications
Definitions
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
- Typical specifications describe the performance met by a majority of models.
- Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.
Specifications are Typical unless otherwise noted.
Conditions
Specifications are valid under the following conditions unless otherwise noted.
- -40 °C to 70 °C
Operating System
| Supported operating system | NI Linux Real-Time (32-bit) |
| Application software |
LabVIEW 2014 SP1 or later LabVIEW FPGA Module 2014 SP1 or later [1]1 LabVIEW FPGA Module is not required when using Scan Interface mode. To program the user-accessible FPGA on the NI-9149, LabVIEW FPGA Module is required. |
| Driver software | NI CompactRIO 14.5 or later |
Memory
Network
| Network interface | 10Base-T, 100Base-T, 1000Base-T Ethernet |
| Compatibility | IEEE 802.3 |
| Communication rates | 10 Mb/s, 100 Mb/s, 1,000 Mb/s auto-negotiated |
| Maximum cabling distance | 100 m/segment |
Internal Real-Time Clock
| Accuracy | 5 ppm |
USB Port
| Type | USB 2.0 Hi-Speed, with standard B connector |
| Maximum data rate | 480 Mb/s |
Reconfigurable FPGA
| Type | Xilinx Zynq-7000, XC7Z020 All Programmable SoC |
| Number of logic cells | 85,000 |
| Number of flip-flops | 106,400 |
| Number of 6-input LUTs | 53,200 |
| Number of DSP slices (18 × 25 multipliers) | 220 |
| Available block RAM | 4480 kbits |
| Number of DMA channels | 16 |
| Number of logical interrupts | 32 |
Battery Life
| Typical battery life with power applied to power connector | 10 years |
| Typical battery life in storage at 55 °C | 5.7 years |
| Minimum battery life in storage at 85 °C | 5.3 years |
Safety Voltages
| V terminal to C terminal | 30 V maximum, Measurement Category I |
Measurement Category
Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
Environmental Guidelines
Environmental Characteristics
| Operating | -40 °C to 70 °C |
| Storage | -40 °C to 85 °C |
| Operating | 10% RH to 90% RH, noncondensing |
| Storage | 5% RH to 95% RH, noncondensing |
| Ingress protection | IP40 |
| Pollution degree | 2 |
| Maximum altitude | 5,000 m |
| Operating vibration - Random | 5 g RMS, 10 Hz to 500 Hz |
| Operating vibration - Sinusoidal | 5 g, 10 Hz to 500 Hz |
| Operating shock | 30 g, 11 ms half sine; 50 g, 3 ms half sine; 18 shocks at 6 orientations |
Power Requirements
| Voltage input range | 9 V DC to 30 V DC |
| Reverse-voltage protection | 30 V DC maximum |
| Maximum power input, with eight C Series modules | 19 W |
| Maximum power input, without C Series modules | 11 W |
Physical Characteristics
| Weight (unloaded) | 1,048 g (36.97 oz) |
| Dimensions (unloaded) | 272.8 mm × 88.1 mm × 62.3 mm (10.74 in. × 3.47 in. × 2.45 in.) |
| Gauge | 0.2 mm 2 to 2.1 mm2 (24 AWG to 14 AWG) copper conductor wire |
| Wire strip length | 6 mm (0.24 in.) of insulation stripped from the end |
| Temperature rating | 85 °C |
| Torque for screw terminals | 0.20 N · m to 0.25 N · m (1.8 lb · in. to 2.2 lb · in.) |
| Wires per screw terminal | One wire per screw terminal |
| Securement type | Screw flanges provided |
| Torque for screw flanges | 0.3 N · m to 0.4 N · m (2.7 lb · in. to 3.5 lb · in.) |
1 LabVIEW FPGA Module is not required when using Scan Interface mode. To program the user-accessible FPGA on the NI-9149, LabVIEW FPGA Module is required.
2 Formatted capacity of nonvolatile memory may be slightly less than this value.
3 To protect the device in harsh, dirty, or wet environments, use NI-9917 and NI-9918 industrial enclosures.