cRIO-9081 Specifications

This document lists the specifications for the NI cRIO-9081.

Processor

CPU

Intel Celeron U3405

Number of cores

2

CPU frequency

1.06 GHz

On-die L2 cache

256 KB x2 (256 KB/core)

On-die L3 cache

2 MB (shared)

Operating System

Note For minimum software support information, visit ni.com/info and enter the Info Code swsupport.

Supported operating system

Windows Embedded Standard 7 Runtime (WES7)

Software requirements
Application software

LabVIEW

LabVIEW 2011 or later, LabVIEW Real-Time Module 2011 or later[1], LabVIEW FPGA Module 2011 or later [2]

Driver software

NI CompactRIO Device Drivers 4.0 or later

Network/Ethernet Port

Number of ports

2

Network interface

10Base-T, 100Base-TX, and 1000Base-T Ethernet

Compatibility

IEEE 802.3

Communication rates

10 Mb/s, 100 Mb/s, 1,000 Mb/s auto-negotiated

Maximum cabling distance

100 m/segment

RS-232 Serial Port

Maximum baud rate

115,200 b/s

Data bits

5, 6, 7, 8

Stop bits

1, 2

Parity

Odd, even, mark, space

Flow control

RTS/CTS, XON/XOFF, DTR/DSR

RI wake maximum low level

0.8 V

RI wake minimum high level

2.4 V

RI overvoltage tolerance

±24 V

RS-485/422 (DTE) Serial Port

Maximum baud rate

230,400 bps

Data bits

5, 6, 7, 8

Stop bits

1, 1.5, 2

Parity

Odd, Even, Mark, Space

Flow control

XON/XOFF

Wire mode

4-wire, 2-wire, 2-wire auto

Isolation voltage, port to earth ground

Continuous

60 VDC, Measurement Category I

Withstand

1,000 Vrms, verified by a 5 s dielectric withstand test

MXI-Express Port

Communication rate

2.5 Gbps

Maximum cabling distance

7 m

USB Ports

Number of ports

4

Note The USB device port is intended for use in device configuration, application deployment, debugging, and maintenance.

USB interface

USB 2.0, Hi-Speed

Maximum data rate

480 Mb/s per port

Maximum current

500 mA

Video Port (VGA)

Maximum resolution

1600 × 1200 at 60 Hz

Memory

Nonvolatile

16 GB minimum

DDR3 system memory

2 GB minimum

Note Visit ni.com/info and enter the Info Code ssdbp for information about the life span of the nonvolatile memory and about best practices for using nonvolatile memory.

Reconfigurable FPGA

FPGA type

Xilinx Spartan-6 LX75

Number of flip-flops

93,296

Number of 6-input LUTs

46,648

Number of DSP slices (18 × 25 multipliers)

132

Available block RAM

3,096 kbits

Number of DMA channels

3

Number of logical interrupts

32

Internal Real-Time Clock

Accuracy

200 ppm; 35 ppm at 25 °C

CMOS Battery

Typical battery life with power applied to power connector

10 years

Typical battery life when stored at temperatures up to 55 °C

5.7 years

Typical battery life when stored at temperatures up to 85 °C

5.3 years

Power Requirements

Caution You must use a UL Listed ITE power supply marked LPS with the cRIO-9081.
Note Some C Series modules have additional power requirements. For more information about C Series module power requirements, refer to the C Series module(s) documentation.
Voltage input range (measured at the cRIO-9081 power connector)

V1

9 V to 30 V

V2

9 V to 30 V

Maximum power consumption

75 W

Note The maximum power consumption specification is based on a fully populated system running a high-stress application at elevated ambient temperature and with all C Series modules and USB devices consuming the maximum allowed power.

Typical standby power consumption at 25 °C

2 W

Recommended power supply

100 W, 24 VDC

Typical leakage current from secondary power input (V2) while system is powered from primary power input (V1)

At 9 V

0.5 mA

At 30 V

2.7 mA

Caution Do not connect V2 to a DC mains supply or to any supply that requires a connecting cable longer than 3 m(10 ft). A DC mains supply is a local DC electricity supply network in the infrastructure of a site or building.
EMC ratings for inputs as described in IEC 61000

V1

Short lines, long lines, and DC distributed networks

V2

Short lines only

Power input connector

4-position, 3.5 mm pitch, pluggable screw terminal with screw locks, Sauro CTF04BV8-AN000A

Physical Characteristics

Tip For two-dimensional drawings and three-dimensional models of the cRIO-9081, visit ni.com/dimensions and search by module number.

Weight (unloaded)

3.1 kg (6.7 lb)

Dimensions (unloaded)

403.7 mm (15.89 in.) × 88.1 mm (3.43 in.) × 121.9 mm (4.80 in.)

Screw-terminal wiring

Gauge

2.0 mm2 to 3.0 mm2 (14 AWG to 12 AWG) copper conductor wire

Wire strip length

7 mm (0.28 in.) of insulation stripped from the end

Temperature rating

85 °C

Torque for screw terminals

0.5 N · m to 0.6 N · m (4.4 lb · in. to 5.3 lb · in.)

Wires per screw terminal

One wire per screw terminal

Connector securement

Securement type

Screw flanges provided

Torque for screw flanges

0.3 N · m to 0.4 N · m (2.7 lb · in. to 3.5 lb · in.)

Safety Voltages

Connect only voltages that are below these limits.

V1 terminal to C terminal

30 V DC maximum, Measurement Category I

V2 terminal to C terminal

30 V DC maximum, Measurement Category I

Chassis ground to C terminal

30 V DC maximum, Measurement Category I

Environmental

Temperature (IEC-60068-2-1 and IEC-60068-2-2)

Operating

0 °C to 45 °C

Operating temperature with NI panel mount kit

0 °C to 55 °C

Storage

-40 °C to 85 °C

Caution Failure to follow the mounting instructions in the user manual can cause temperature derating. Visit ni.com/info and enter Info Code criomounting for more information about mounting configurations and temperature derating.

Ingress protection

IP20

Operating humidity (IEC 60068-2-56)

10% RH to 90% RH, noncondensing

Storage humidity (IEC 60068-2-56)

5% RH to 95% RH, noncondensing

Pollution Degree (IEC 60664)

2

Maximum altitude

2,000 m

Indoor use only.

Hazardous Locations

U.S. (UL)

Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx nA IIC T4 Gc

Canada (C-UL)

Class I, Division 2, Groups A, B, C, D, T4; Ex nA IIC T4 Gc

Europe (ATEX) and International (IECEx)

Ex nA IIC T4 Gc

DEMKO 07 ATEX 0626664X

IECEx UL 14.0089X

Shock and Vibration

To meet these specifications, you must mount the cRIO-9081 system directly on a flat, rigid surface as described in the user manual, affix ferrules to the ends of the terminal wires, install an SD card cover (SD Door Kit, 783660-01), and use retention accessories for the USB host ports (NI Industrial USB Extender Cable, 152166-xx), USB device port (NI Locking USB Cable, 157788-01), and mini DisplayPort connector (NI Retention Accessory for Mini DisplayPort, 156866-01). All cabling should be strain-relieved near input connectors. Take care to not directionally bias cable connectors within input connectors when applying strain relief.

Operating vibration

Random

5 g RMS, 10 Hz to 500 Hz

Sinusoidal

5 g, 10 Hz to 500 Hz

Operating shock

30 g, 11 ms half sine; 50 g, 3 ms half sine; 18 shocks at 6 orientations

Safety Compliance and Hazardous Locations Standards

This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:

  • IEC 61010-1, EN 61010-1
  • UL 61010-1, CSA C22.2 No. 61010-1
  • EN 60079-0, EN 60079-7
  • IEC 60079-0, IEC 60079-7
  • UL 60079-0, UL 60079-7
  • CSA C22.2 No. 60079-0, CSA C22.2 No. 60079-7
Note For safety certifications, refer to the product label or the Product Certifications and Declarations section.

Electromagnetic Compatibility

  • EN 61326 EMC requirements; Industrial Immunity
  • EN 55011 Emissions; Group 1, Class A
  • CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
Note For EMC compliance, operate this device according to product documentation.

CE Compliance 1378

  • 2014/34/EU; Potentially Explosive Atmospheres (ATEX)

Product Certifications and Declarations

Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.

Environmental Management

NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.

For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.

EU and UK Customers

  • 1378 Waste Electrical and Electronic Equipment (WEEE)—At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee.
  • Battery Replacement and Disposal

  • 1378 Battery Directive—This product contains a long-life coin cell battery. If you need to replace it, use the Return Material Authorization (RMA) process or contact an authorized NI service representative. For more information about compliance with the EU Battery Directive 2006/66/EC about Batteries and Accumulators and Waste Batteries and Accumulators, visit ni.com/environment/batterydirective.
  • 电子信息产品污染控制管理办法(中国RoHS)

  • 1378 中国RoHSNI符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于NI中国RoHS合规性信息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)
  • NI Services

    Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples.

    Visit ni.com/services to learn about NI service offerings such as calibration options, repair, and replacement.

    Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI.

    NI corporate headquarters is located at 11500 N Mopac Expwy, Austin, TX, 78759-3504, USA.

    1 LabVIEW Real-Time Module is only required when using a Real-Time cRIO-9081.

    2 LabVIEW FPGA Module is not required when using Scan Interface mode. To program the user-accessible FPGA on the cRIO-9081, LabVIEW FPGA Module is required.