Product Descriptions

cRIO-9040: 1.30 GHz Dual-Core CPU, 2 GB DRAM, 4 GB Storage, -20 °C to 55 °C, Kintex-7 70T FPGA, 4-Slot CompactRIO Controller

cRIO-9041: 1.30 GHz Dual-Core CPU, 2 GB DRAM, 4 GB Storage, -40 °C to 70 °C, Kintex-7 70T FPGA, 4-Slot CompactRIO Controller

cRIO-9042: 1.60 GHz Quad-Core CPU, 4 GB DRAM, 4 GB Storage, -40 °C to 70 °C, Kintex-7 70T FPGA, 4-Slot CompactRIO Controller

cRIO-9043: 1.30 GHz Dual-Core CPU, 2 GB DRAM, 8 GB Storage, -40 °C to 70 °C, Kintex-7 160T FPGA, 4-Slot CompactRIO Controller

cRIO-9045: 1.30 GHz Dual-Core CPU, 2 GB DRAM , 4 GB Storage, -20 °C to 55 °C, Kintex-7 70T FPGA, 8-Slot CompactRIO Controller

cRIO-9046: 1.30 GHz Dual-Core CPU, 2 GB DRAM, 4 GB Storage, -40 °C to 70 °C, Kintex-7 70T FPGA, 8-Slot CompactRIO Controller

cRIO-9047: 1.60 GHz Quad-Core CPU, 4 GB Storage, -40 °C to 70 °C, Kintex-7 70T FPGA, 8-Slot CompactRIO Controller

cRIO-9048: 1.30 GHz Dual-Core CPU, 2 GB DRAM, 8 GB Storage, -40 °C to 70 °C, Kintex-7 160T FPGA, Extended Temperature, 8-Slot CompactRIO Controller

cRIO-9049: 1.60 GHz Quad-Core CPU, 4 GB DRAM, 16 GB Storage, -20 to 55 °C, Kintex-7 325T FPGA, 8-Slot CompactRIO Controller

Physical Characteristics

Weight

cRIO-9040

1,800 g (3 lb 15 oz)

cRIO-9041

1,800 g (3 lb 15 oz)

cRIO-9042

1,800 g (3 lb 15 oz)

cRIO-9043

1,800 g (3 lb 15 oz)

cRIO-9045

2,250 g (4 lb 15 oz)

cRIO-9046

2,250 g (4 lb 15 oz)

cRIO-9047

2,250 g (4 lb 15 oz)

cRIO-9048

2,250 g (4 lb 15 oz)

cRIO-9049

2,250 g (4 lb 15 oz)

Dimensions (unloaded)

cRIO-9040

219.5 mm × 88.1 mm × 121.2 mm (8.64 in. × 3.47 in. × 4.77 in.)

cRIO-9041

219.5 mm × 88.1 mm × 121.2 mm (8.64 in. × 3.47 in. × 4.77 in.)

cRIO-9042

219.5 mm × 88.1 mm × 121.2 mm (8.64 in. × 3.47 in. × 4.77 in.)

cRIO-9043

219.5 mm × 88.1 mm × 121.2 mm (8.64 in. × 3.47 in. × 4.77 in.)

cRIO-9045

328.8 mm × 88.1 mm × 121.2 mm (12.94 in. × 3.47 in. × 4.77 in.)

cRIO-9046

328.8 mm × 88.1 mm × 121.2 mm (12.94 in. × 3.47 in. × 4.77 in.)

cRIO-9047

328.8 mm × 88.1 mm × 121.2 mm (12.94 in. × 3.47 in. × 4.77 in.)

cRIO-9048

328.8 mm × 88.1 mm × 121.2 mm (12.94 in. × 3.47 in. × 4.77 in.)

cRIO-9049

328.8 mm × 88.1 mm × 121.2 mm (12.94 in. × 3.47 in. × 4.77 in.)

Power Connector

Power connector wiring

Gauge

0.5 mm2 to 2.1 mm2 (20 AWG to 14 AWG) copper conductor wire

Wire strip length

6 mm (0.24 in.) of insulation stripped from the end

Temperature rating

85 °C

Torque for screw terminals

0.20 N · m to 0.25 N · m (1.8 lb · in. to 2.2 lb · in.)

Wires per screw terminal

One wire per screw terminal

Connector securement

Securement type

Screw flanges provided

Torque for screw flanges

0.20 N · m to 0.25 N · m (1.8 lb · in. to 2.2 lb · in.)

Insulation rating

300 V, maximum

Environmental

Operating temperature

cRIO-9040

-20 °C to 55 °C

cRIO-9041

-40 °C to 70 °C

cRIO-9042

-40 °C to 70 °C

cRIO-9043

-40 °C to 70 °C

cRIO-9045

-20 °C to 55 °C

cRIO-9046

-40 °C to 70 °C

cRIO-9047

-40 °C to 70 °C

cRIO-9048

-40 °C to 70 °C

cRIO-9049

-20 °C to 55 °C

Storage temperature

-40 °C to 85 °C

Ingress protection

IP20

Operating humidity

10% RH to 90% RH, noncondensing

Storage humidity

5% RH to 95% RH, noncondensing

Pollution Degree

2

Maximum altitude

5,000 m

Indoor use only.

Hazardous Locations

Explosive atmospheres rating

Ex ec IIC T4 Gc

CCC certificate number

2021312304000993

Safety Guidelines

Operate the product only as described in this document.

Caution Take precautions to avoid injury. Consult the model documentation for cautionary statements when you see this icon printed on the model.
Caution Observe all instructions and cautions in the user documentation. Using the model in a manner not specified can damage the model and compromise the built-in safety protection. Return damaged models to NI for repair.

Safety Guidelines for Hazardous Locations

The cRIO-9040/9045/9049 have been evaluated as Ex ec IIC T4 Gc equipment and are CCC certified. Each product is suitable for use within ambient temperatures of -20 °C ≤ Ta ≤55 °C in either nonhazardous locations or Zone 2 hazardous locations.

The cRIO-9041/9042/9043/9046/9047/9048 have been evaluated as Ex ec IIC T4 Gc equipment and are CCC certified. Each product is suitable for use within ambient temperatures of -40 °C ≤ Ta ≤70 °C in either nonhazardous locations or Zone 2 hazardous locations.

Follow these guidelines if you are installing the product in a potentially explosive environment. Not following these guidelines may result in serious injury or death.

Caution Do not disconnect the power supply wires, I/O-side wires, or connectors from the controller unless power has been switched off or the area is known to be nonhazardous.
Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous.
Caution Substitution of components may impair suitability for Zone 2.
Caution Transient protection shall be provided that is set at a level not exceeding 140% of the peak rated voltage value at the supply terminals to the equipment.
Caution The system shall only be used in an area of not more than Pollution Degree 2, as defined in IEC/EN 60664-1.
Caution The system shall be mounted in a CCC-certified enclosure with a minimum ingress protection rating of at least IP54 as defined in GB/T3836.1.

Safety Voltages

Connect only voltages that are below these limits.

V1 terminal to C terminal

30 V, maximum

V2 terminal to C terminal

30 V, maximum

Chassis ground to C terminal

30 V, maximum

Caution Do not connect the product to signals or use for measurements within Measurement Categories II, III, or IV.

Power Requirements

Voltage input range (measured at the cRIO controller power connector)

V1

9 V to 30 V

V2

9 V to 30 V

Maximum power consumption

60 W

Recommended power supply

100 W, 24 V DC

Installing C Series Modules

Verify that power is not connected to the I/O connector(s) on the C Series module.

Removing C Series Modules

Verify that power is not connected to the I/O connector(s) on the C Series module before you remove a module from the chassis.

Safety Compliance and Hazardous Locations Standards

This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:

  • IEC 61010-1
  • IEC 60079-0, IEC 60079-7
  • GB/T3836.1, GB/T3836.3
Note For safety certifications, refer to the product label or the Product Certifications and Declarations section.

Product Certifications and Declarations

To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.

Worldwide Support and Services

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504, USA.