Product Descriptions
- Updated2022-05-02
- 9 minute(s) read
Product Descriptions
NI-9260: 51.2 kS/s/ch Simultaneous, 3 Vrms, 2-Channel C Series Voltage Output Module
NI-9262: 1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module
NI-9263: 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module
NI-9264: 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module
NI-9269: 100 kS/s/ch Simultaneous, ±10 V, Isolated, 4-Channel C Series Voltage Output Module
Physical Characteristics
| |||||||||||||||||||||
Dimensions | Visit ni.com/dimensions and search by module number. |
NI-9263 with screw terminal
| |||||||||||||||
|
NI-9263 with spring terminal
| |||||||||||
Ferrules | 0.25 mm2 to 2.5 mm2 | ||||||||||
|
NI-9264 with push-in spring terminal
(black/orange connector)
| |||||||||||||
|
NI-9264 with spring terminal (black
connector)
| |||||||||||
|
NI-9269
| |||||||||||||||
|
Environmental
Refer to the manual for the chassis you are using for more information about meeting these specifications.
Operating temperature | -40 °C to 70 °C | ||||||||||||||||
Storage temperature | -40 °C to 85 °C | ||||||||||||||||
Ingress protection | IP40 | ||||||||||||||||
Operating humidity | 10% RH to 90% RH, noncondensing | ||||||||||||||||
Storage humidity | 5% RH to 95% RH, noncondensing | ||||||||||||||||
Pollution Degree | 2 | ||||||||||||||||
|
Indoor use only.
Hazardous Locations
Explosive atmospheres rating | Ex ec IIC T4 Gc |
CCC certificate number | 2021312310000312 |
Safety Guidelines
Operate the product only as described in this document.
Safety Guidelines for Hazardous Voltages
(Screw Terminal and Spring Terminal Products)
If hazardous voltages are connected to the device, take the following precautions. A hazardous voltage is a voltage greater than 42.4 V peak voltage or 60 V DC to earth ground.
You may connect signals which may be floating at hazardous voltages only to the products with screw terminal or spring terminal connectors. Do not connect hazardous voltages to the products with DSUB, BNC, or mini XLR connectors.
Safety Guidelines for Hazardous Locations
These products have been evaluated as Ex ec IIC T4 Gc equipment and are CCC certified. Each product is suitable for use within ambient temperatures of -40 °C ≤ Ta ≤ 70 °C in either nonhazardous locations or Zone 2 hazardous locations. If you are using the products in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex ec IIC T4 Gc equipment.
Follow these guidelines if you are installing the product in a potentially explosive environment. Not following these guidelines may result in serious injury or death.
Safety Voltages
NI-9260 with BNC, NI-9260 with Mini
XLR
AO-to-COM voltage | 3.16 V RMS (±4.68 V peak) maximum | ||||||
Overvoltage protection | ±30 V | ||||||
Channel-to-earth ground | ±30 V maximum | ||||||
|
NI-9262 with DSUB
Connect only voltages that are within the following limits.
AO-to-COM | ±30 V maximum | ||||||||||||
Overvoltage protection | ±30 V maximum | ||||||||||||
|
NI-9263 with Screw Terminal, NI-9263 with
Spring Terminal
Connect only voltages that are within the following limits:
AO-to-COM | ±11 V maximum | ||||||
Overvoltage protection | ±30 V | ||||||
Channel-to-channel | None | ||||||
| |||||||
Zone 2 hazardous locations applications (Channel-to-earth ground) | 60 V DC, Measurement Category I |
NI-9264 with Push-In Spring Terminal
(Black/Orange Connector)
Connect only voltages that are within the following limits:
AO-to-COM | ±10.65 V maximum | ||||||
Overvoltage protection | ±27 V at 25 °C | ||||||
Channel-to-channel | None | ||||||
|
NI-9264 with Spring Terminal (Black
Connector)
Connect only voltages that are within the following limits:
|
NI-9264 with DSUB
Connect only voltages that are within the following limits:
|
NI-9269 with Screw Terminal
Connect only voltages that are within the following limits:
AO-to-COM | ±10.56 V maximum | ||||||
Overvoltage protection | ±30 V | ||||||
| |||||||
| |||||||
Zone 2 hazardous locations applications (Channel-to-channel and channel-to-earth ground) | 60 V DC, Measurement Category I |
Installing C Series Modules
Verify that power is not connected to the I/O connector(s) on the C Series module.
Removing C Series Modules
Verify that power is not connected to the I/O connector(s) on the C Series module before you remove a module from the chassis.
Safety Compliance and Hazardous Locations Standards
This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
- IEC 61010-1
- IEC 60079-0, IEC 60079-7
- GB/T3836.1, GB/T3836.3
Product Certifications and Declarations
To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
Worldwide Support and Services
NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504, USA.