January 2022
This file contains late breaking news about NI-Serial and supersedes any information found in other documentation included in the distribution.
Refer to for the most recent information about Linux support at National Instruments.
Refer to NI-Serial Release Notes for known issues, bugs fixed since the last release, and other release details.
NI-Serial software for the Linux/x86 64-bit architecture has been tested on the following distributions:
NI-Serial requires a 64-bit distribution and does not support 32-bit applications.
PCI Interfaces | Standard | Number of Ports | Isolated | Max Baud (kbaud) |
---|---|---|---|---|
PCI-8430/2 | RS-232 | 2 | No | 1000.0 |
PCI-8430/4 | RS-232 | 4 | No | 1000.0 |
PCI-8430/8 | RS-232 | 8 | No | 1000.0 |
PCI-8430/16 | RS-232 | 16 | No | 1000.0 |
PCI-8431/2 | RS-485/RS-422 | 2 | No | 3000.01 |
PCI-8431/4 | RS-485/RS-422 | 4 | No | 3000.01 |
PCI-8431/8 | RS-485/RS-422 | 8 | No | 3000.01 |
PCI-8432/2 | RS-232 | 2 | Yes | 1000.0 |
PCI-8432/4 | RS-232 | 4 | Yes | 1000.0 |
PCI-8433/2 | RS-485/RS-422 | 2 | Yes | 3000.01 |
PCI-8433/4 | RS-485/RS-422 | 4 | Yes | 3000.01 |
PCI Express Interfaces | Standard | Number of Ports | Isolated | Max Baud (kbaud) |
---|---|---|---|---|
PCIe-8430/2 | RS-232 | 2 | No | 1000.0 |
PCIe-8430/8 | RS-232 | 8 | No | 1000.0 |
PCIe-8430/16 | RS-232 | 16 | No | 1000.0 |
PCIe-8431/2 | RS-485/RS-422 | 2 | No | 3000.01 |
PCIe-8431/8 | RS-485/RS-422 | 8 | No | 3000.01 | PCIe-8431/16 | RS-485/RS-422 | 16 | No | 3000.01 |
PCIe-8432/2 | RS-232 | 2 | Yes | 1000.01 |
PCIe-8433/2 | RS-485/RS-422 | 2 | Yes | 1000.01 |
PXI Interfaces | Standard | Number of Ports | Isolated | Max Baud (kbaud) |
---|---|---|---|---|
PXI-8430/2 | RS-232 | 2 | No | 1000.0 |
PXI-8430/4 | RS-232 | 4 | No | 1000.0 |
PXI-8430/8 | RS-232 | 8 | No | 1000.0 |
PXI-8430/16 | RS-232 | 16 | No | 1000.0 |
PXI-8431/2 | RS-485/RS-422 | 2 | No | 3000.01 |
PXI-8431/4 | RS-485/RS-422 | 4 | No | 3000.01 |
PXI-8431/8 | RS-485/RS-422 | 8 | No | 3000.01 |
PXI-8432/2 | RS-232 | 2 | Yes | 1000.0 |
PXI-8432/4 | RS-232 | 4 | Yes | 1000.0 |
PXI-8433/2 | RS-485/RS-422 | 2 | Yes | 3000.01 |
PXI-8433/4 | RS-485/RS-422 | 4 | Yes | 3000.01 |
PXI Express Interfaces | Standard | Number of Ports | Isolated | Max Baud (kbaud) |
---|---|---|---|---|
PXIe-8430/8 | RS-232 | 8 | No | 1000.0 |
PXIe-8430/16 | RS-232 | 16 | No | 1000.0 |
PXIe-8431/8 | RS-485/RS-422 | 8 | No | 3000.01,2 |
PXIe-8431/16 | RS-485/RS-422 | 16 | No | 3000.01,2 |
1The two-wire auto control mode for RS-485 transceiver control has a maximum baud rate of 2 Mbaud.
2For possible use with higher baud rates, refer to ni.com/kb and search for KnowledgeBase 58KEI82F.
NI provides a repository add-on for all supported drivers that you can install using your Linux distribution's native package manager.
After the driver package(s) are installed, you must rebuild the new packages for the system kernel. NI recommends that you run the command 'dkms autoinstall' after installation, and before rebooting the system, to install the latest revision of all modules that have been installed for other kernel revisions. After doing so, the installed device drivers will function immediately on the next system start.
Use a web browser to view the NI-Serial documentation at ni.com/manuals
This publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.
NI respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.
Notices are located in the /usr/share/doc/
If you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.
Content from the IVI specifications reproduced with permission from the IVI Foundation.
The IVI Foundation and its member companies make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The IVI Foundation and its member companies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.
For patents covering the NI products/technology, refer to the NI Patent Notice at ni.com/patents.
378686B-01