October 2022
This file contains installation instructions and compatibility information for VeriStand 2021 R3.
You can find more release information on ni.com.
Product Security and Critical Updates
Upgrade and Compatibility Issues
Automating the Installation of NI Products
Using NI Software with Microsoft Windows 11
Using NI Software with Microsoft Windows 10
Unsupported Windows Operating Systems
VeriStand is configuration-based testing software, allowing you to develop, prototype, and test control systems using hardware I/O and simulation models. The VeriStand software framework enables you to perform real-time or PC-based test configuration and execution that can be customized and extended with LabVIEW, NI TestStand, and other software tools. Use VeriStand's run-time editable user interface to implement triggered multi-file data logging, stimulus generation and playback, and real-time test sequencing.
VeriStand 2021 R3 installs with the following:
Refer to the following sections for system requirements that apply if you use models, LabVIEW functionality, and .NET APIs.
To configure and run a simulation using your existing compiled model, you need only VeriStand installed. You need the following additional software to perform other tasks with models:
Note You do not need the full VeriStand environment to generate a compatible model. Instead, you can install VeriStand Model Generation Support Toolbox for Simulink or the VeriStand Model Framework.
If you use other modeling environments, contact your model vendor for specific requirements.
To create custom devices, menu items, workspace controls and indicators, or timing and sync devices, you must have LabVIEW 2021 SP1 64-bit. The LabVIEW functionality in VeriStand always requires like-numbered versions.
The VeriStand .NET APIs require the following Microsoft software:
VeriStand 2021 R3 supports the following operating systems:
Windows Systems | Real-Time Targets |
---|---|
|
|
1 NI software installs VC2015 Runtime and .NET 4.6.2. 2 VeriStand no longer supports Phar Lap ETS or NI Linux Real-Time (ARM-based) targets. |
When formatting a disk with a PXI Linux RT system image for VeriStand 2021 R3, select Linux RT System Image 2022 Q4 and enable support for the LabVIEW 2021 programming environment. Doing so prevents driver version conflicts while deploying XNET to a real-time target.
Install VeriStand with either the online installer or with installation media.
Download the VeriStand installer from ni.com/downloads. NI software includes NI Package Manager to handle the installation. Refer to the NI Package Manager Manual for more information about installing, removing, and upgrading NI software using NI Package Manager.
If you purchased this product with media, insert the VeriStand installation media and follow the instructions that appear on the screen.
Visit ni.com/security to view and subscribe to receive security notifications about NI products. For information about critical updates from NI, refer to Available Critical and Security Updates for NI Software.
The following sections describe issues to be aware of when you upgrade to VeriStand 2021 R3.
Note NI recommends that you review the Upgrade and Compatibility Issues in the readme files for each VeriStand version between the version from which you are upgrading and VeriStand 2021 R3. To access the documents, refer to the VeriStand Release Notes.
VeriStand does not support communication with uncompiled models.
Models compiled from LabVIEW VIs (.lvmodel or .lvmodelso files) using earlier versions of LabVIEW must be recompiled using LabVIEW 2021 SP1 64-bit. The LabVIEW functionality in VeriStand requires like-numbered versions.
Take the following actions to ensure your models are 64-bit compatible:
Beginning with VeriStand 2021, the VeriStand Model Framework contains changes to the files used to develop and compile models in C/C++ and third-party modeling environments. If your system contains models compiled for Linux RT 64-bit with previous versions of the Model Framework, choose from the following options to continue to use the models:
VeriStand 2021 R3 can open projects from VeriStand 2010 to 2018 SP1 using the Open Legacy Project option in the Welcome tab.
Beginning with VeriStand 2021, the VeriStand suite installer will include custom devices for both offline and online installation. To install custom devices separately, refer to the release page for each Custom Device on the VeriStand Add-ons support page.
VeriStand includes the following documentation resources:
Resource | Contents | Access Instructions |
---|---|---|
VeriStand Help | Conceptual, how-to, and reference information for using VeriStand. | In software: Help»Show VeriStand Help... OR Windows Start menu: All Programs»National Instruments»VeriStand 2021 R3 Help |
VeriStand .NET API Help | Reference information for the .NET APIs included with VeriStand. You can access these assemblies from any .NET-compatible programming language or environment, including LabVIEW and NI TestStand. | Windows Start menu: All Programs»National Instruments»VeriStand 2021 R3 .NET API Help. |
Note If you install VeriStand with a compatible version of LabVIEW, you can access a subset of VeriStand related materials in the LabVIEW Help. This includes information about VeriStand VIs and extending VeriStand functionality. To access this help from LabVIEW, select Help»LabVIEW Help.
VeriStand includes the following types of examples:
You can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes.
If the NI product you are installing uses Microsoft .NET 4.6.2, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.6.2 separately before you install NI software.
For more information about automating the installation of NI products, refer to Automating an Installer in the NI Package Manager documentation.
Microsoft Windows 11 is the latest version of the Windows operating system and features significant changes compared to previous versions. For more information about NI support for Windows 11, refer to NI Product Compatibility for Microsoft Windows 11.
For more information about NI support for Windows 10, refer to NI Product Compatibility for Microsoft Windows 10.
VeriStand no longer supports Windows Vista/XP/7/8.x, Windows Server 2003/2008/2012, or any 32-bit Windows operating system. Versions of this product that ship after May 1, 2021, may not install or execute correctly on these operating systems. For detailed information about NI operating system support, visit https://www.ni.com/r/win32bitsupport.
Copyright
© 2009–2022 National Instruments Corporation. All rights reserved.
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.
NI respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.
End-User License Agreements and Third-Party Legal Notices
You can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:
U.S. Government Restricted Rights
If you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.
IVI Foundation Copyright Notice
Content from the IVI specifications reproduced with permission from the IVI Foundation.
The IVI Foundation and its member companies make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The IVI Foundation and its member companies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Trademarks
Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.
Patents
For patents covering the NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the NI Patent Notice at ni.com/patents.