July 2022
This file contains installation instructions and compatibility information for LabVIEW 2022 Q3.
You can find more release information on ni.com.
Product Security and Critical Updates
Automating the Installation of NI Products
Using NI Software with Microsoft Windows 10
Unsupported Windows Operating Systems
LabVIEW 2022 Q3 has the following requirements:
Windows | Run-Time Engine | Development Environment |
---|---|---|
Processor | Pentium 4M/Celeron 866 MHz (or equivalent) or later (32-bit) Pentium 4 G1 (or equivalent) or later (64-bit) | Pentium 4M (or equivalent) or later (32-bit) Pentium 4 G1 (or equivalent) or later (64-bit) |
RAM | 256 MB | 1 GB |
Screen Resolution | 1024 x 768 pixels | 1024 x 768 pixels |
Disk Space | 620 MB | 5 GB (includes default drivers) |
Color Palette | N/A | LabVIEW and the LabVIEW Help contain 16-bit color graphics. LabVIEW requires a minimum color palette setting of 16-bit color. |
Temporary Files Directory | N/A | LabVIEW uses a directory for storing temporary files. NI recommends that you have several megabytes of disk space available for this temporary directory. |
Adobe Reader | N/A | You must have Adobe Reader 7.0 or later installed to search PDF versions of all LabVIEW manuals. |
LabVIEW 2022 Q3 supports the following operating systems:
Note Refer to Unsupported Windows Operating Systems for more information about support for Microsoft Windows OSes.
Note LabVIEW no longer supports Windows Vista/XP/7/8.x, Windows Server 2003/2008/2012, or any 32-bit Windows operating system. LabVIEW 2022 Q3 will not install or run on an unsupported OS. You cannot deploy or distribute applications that use LabVIEW 2022 Q3 to an unsupported OS. Additionally, after installing LabVIEW 2022 Q3, you cannot use any installers built on this computer with any version of LabVIEW, LabWindows™/CVI™, NI TestStand™, or Measurement Studio on an unsupported OS.
For more information about the changes to our OS support, visit https://www.ni.com/r/win32bitsupport.
Download the LabVIEW installer from ni.com/downloads. NI software includes NI Package Manager to handle the installation. Refer to the NI Package Manager Manual for more information about installing, removing, and upgrading NI software using NI Package Manager.
Notes
If you install software using the LabVIEW Platform media, insert the LabVIEW Platform media and follow the onscreen instructions to install LabVIEW, modules, toolkits, and drivers. When prompted, log in to your NI User Account to activate your NI products. If you are managing your license with a volume license server, you should receive your volume license file by email.
Refer to Upgrading LabVIEW for information about protecting existing VIs and projects before installing a new version of LabVIEW, as well as upgrade and compatibility issues and a complete list of new features in LabVIEW 2022 Q3.
Visit ni.com/security to view and subscribe to receive security notifications about NI products. Visit ni.com/r/critical-updates for information about critical updates from NI.
Use the LabVIEW Platform media to install modules and toolkits supported by LabVIEW 2022 Q3 (32-bit) and LabVIEW 2022 Q3 (64-bit). LabVIEW (64-bit) provides access to more memory than a 32-bit operating system or what a 32-bit application can provide. LabVIEW (64-bit) is available in English only.
Refer to the NI website for information about drivers compatible with LabVIEW 2022 Q3 (64-bit). Refer to the specific hardware documentation for more information about compatibility with LabVIEW (64-bit).
LabVIEW 2022 Q3 (64-bit) supports a limited number of modules and toolkits. The following table compares the modules and toolkits supported by LabVIEW (32-bit) and LabVIEW (64-bit).
Product | LabVIEW 2022 Q3 (32-bit) | LabVIEW 2022 Q3 (64-bit) |
---|---|---|
Advanced Signal Processing Toolkit3 | ✓ | ✓ |
Application Builder Module3 | ✓ | ✓ |
Control Design and Simulation Module | ✓ | ✓1 |
Database Connectivity Toolkit3 | ✓ | ✓ |
Datalogging and Supervisory Control Module | ✓ | — |
Desktop Execution Trace Toolkit for Windows3 | ✓ | ✓ |
Digital Filter Design Toolkit3 | ✓ | ✓ |
FPGA Module | ✓ | ✓ |
MathScript Module | ✓ | ✓2 |
Real-Time Module | ✓ | ✓ |
Report Generation Toolkit for Microsoft Office3 | ✓ | ✓ |
Sound and Vibration Toolkit | ✓ | ✓ |
Unit Test Framework Toolkit3 | ✓ | ✓ |
VI Analyzer Toolkit3 | ✓ | ✓ |
Vision Development Module | ✓ | ✓ |
1 The Control Design and Simulation Module (64-bit) does not support the System Identification Assistant, Control Design Assistant, and real-time targets. 2 The MathScript Module (64-bit) does not support the libraries class of MathScript Module functions. 3These modules and toolkits are only available with the LabVIEW Professional Development System. |
Refer to the readme of each product for more information about 32-bit and 64-bit support, system requirements, installation instructions, and activation. For information about products not listed in the previous table, refer to the user documentation of those products.
You can use the LabVIEW debug and deployment license to fix issues on an application or system that was previously created with one of the development licenses of LabVIEW.
Debug and deployment license activates your edition of LabVIEW, LabVIEW FPGA, LabVIEW Real-Time, all LabVIEW toolkits, and the LabVIEW Mathscript Module.
Select Help»Find Examples from LabVIEW to launch the NI Example Finder. You can modify an example VI to fit an application, or you can copy and paste from one or more examples into a VI that you create.
You can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes.
If the NI product you are installing uses Microsoft .NET 4.6.2, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.6.2 separately before you install NI software.
For more information about automating the installation of NI products, refer to Automating an Installer in the NI Package Manager manual.
For more information about NI support for Windows 10, refer to NI Product Compatibility for Microsoft Windows 10.
LabVIEW no longer supports Windows Vista/XP/7/8.x, Windows Server 2003/2008/2012, or any 32-bit Windows operating system. Versions of this product that ship after May 1, 2021, may not install or execute correctly on these operating systems. For detailed information about NI operating system support, visit https://www.ni.com/r/win32bitsupport.
Copyright
© 2004–2022 National Instruments Corporation. All rights reserved.
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.
NI respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.
End-User License Agreements and Third-Party Legal Notices
You can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:
U.S. Government Restricted Rights
If you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.
IVI Foundation Copyright Notice
Content from the IVI specifications reproduced with permission from the IVI Foundation.
The IVI Foundation and its member companies make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The IVI Foundation and its member companies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Trademarks
Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.
An NI Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
Patents
For patents covering the NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the NI Patent Notice at ni.com/patents.