LabVIEW 2023 Q1 and Drivers Readme

January 2023

This file contains installation instructions and compatibility information for LabVIEW 2023 Q1 and Drivers.

You can find more release information on ni.com.

System Requirements

Supported Operating Systems

Products Included in the LabVIEW 2023 Q1 and Drivers Installer

Installation Instructions

Product Security and Critical Updates

Supported Hardware

Finding Examples

Automating the Installation of NI Products

Using NI Software with Microsoft Windows 11

Unsupported Windows Operating Systems

NI no longer supports Phar Lap ETS Real-Time Operating System


System Requirements

LabVIEW 2023 Q1 and Drivers has the following requirements:

Windows Run-Time Engine Development Environment
Processor Pentium 4M/Celeron 866 MHz (or equivalent) or later (32-bit)
Pentium 4 G1 (or equivalent) or later (64-bit)
Pentium 4M (or equivalent) or later (32-bit)
Pentium 4 G1 (or equivalent) or later (64-bit)
RAM 256 MB 1 GB
Screen Resolution 1024 x 768 pixels 1024 x 768 pixels
Disk Space 620 MB 5 GB (includes default drivers)
Color Palette N/A LabVIEW and the LabVIEW Help contain 16-bit color graphics. LabVIEW requires a minimum color palette setting of 16-bit color
Temporary Files Directory N/A LabVIEW uses a directory for storing temporary files. NI recommends that you have several megabytes of disk space available for this temporary directory
Adobe Reader N/A You must have Adobe Reader 7.0 or later installed to search PDF versions of all LabVIEW manuals

Supported Operating Systems

LabVIEW 2023 Q1 and Drivers supports the following operating systems:

  • Windows 11
  • Windows 10
  • Windows Server 2022
  • Windows Server 2019
  • Windows Server 2016

Products Included in the LabVIEW 2023 Q1 and Drivers Installer

Application Software

Product Version Bitness
G Web Development Software1 2022 Q3 64-bit
LabVIEW 2023 Q1 32-bit and 64-bit
1 Evaluation mode only

Note: This product no longer supports LabVIEW NXG. Refer to LabVIEW NXG on ni.com for more information about LabVIEW NXG Life-Cycle Dates and driver version support.

Add-ons

Product Version Bitness
JKI VI Package Manager 2022 Q3 32-bit and 64-bit
LabVIEW Datalogging and Supervisory Control Module 2023 Q1 32-bit
LabVIEW Datalogging and Supervisory Control Runtime 2023 Q1 32-bit
LabVIEW FPGA Compilation Tool for Vivado 2021.1 2022 Q3 64-bit
LabVIEW FPGA Compile Farm Toolkit 2023 Q1 32-bit and 64-bit
LabVIEW FPGA Module 2023 Q1 32-bit and 64-bit
LabVIEW Real-Time Module 2023 Q1 32-bit and 64-bit
Vision Acquisition Software (includes IMAQ, IMAQdx, IMAQ I/O) 2023 Q1 32-bit and 64-bit
Vision Development Module 2023 Q1 32-bit and 64-bit

Note: The LabVIEW Professional Development System installs the LabVIEW Advanced Signal Processing Toolkit, LabVIEW Desktop Execution Trace Toolkit, LabVIEW Digital Filter Design Toolkit, LabVIEW Unit Test Framework Toolkit, LabVIEW VI Analyzer Toolkit, LabVIEW Database Connectivity Toolkit and the LabVIEW Report Generation Toolkit. You can locate the readmes for these products in the labview\readme directory.

Drivers

Product Version Bitness
FlexRIO with Integrated I/O 2023 Q1 32-bit and 64-bit
FlexRIO with Modular I/O 2023 Q1 32-bit and 64-bit
IVI Compliance Package 2022 Q3 32-bit and 64-bit
NI CompactRIO 2023 Q1 32-bit and 64-bit
NI-488.2 2022 Q4 32-bit and 64-bit
NI-DAQmx 2023 Q1 32-bit and 64-bit
NI-DCPower 2022 Q3 32-bit and 64-bit
NI-DMM 2023 Q1 32-bit and 64-bit
NI-FGEN 2023 Q1 32-bit and 64-bit
NI-SCOPE 2023 Q1 32-bit and 64-bit
NI-Serial 21.5 32-bit and 64-bit
NI-SWITCH 2023 Q1 32-bit and 64-bit
NI-Sync 2023 Q1 32-bit and 64-bit
NI-VISA 2022 Q3 32-bit and 64-bit
NI-XNET 2023 Q1 32-bit and 64-bit
PXI Platform Services 2023 Q1 32-bit and 64-bit

Note: Some drivers included with previous versions of LabVIEW and Drivers are not included with this release. Visit ni.com/downloads for the latest driver versions.

Microsoft Visual Studio Support

If you are using the LabVIEW .NET Class Library, .NET Framework 4.0 (minimum) is required. The LabVIEW 2023 Q1 and Drivers .NET Class Library can be used with Visual C# or Visual Basic .NET in any Visual Studio version that can target .NET Framework 4.0 or .NET Framework 4.5.

To use the .NET API, you must install the .NET class libraries or the .NET wrapper in addition to the NI device driver. For information about versions of the .NET Framework and the drivers each supports, as well as the download location of the installer files, refer to .NET Resources for NI Hardware and Software.

Installation Instructions

Download the LabVIEW installer from ni.com/downloads. NI software includes NI Package Manager to handle the installation. Refer to the NI Package Manager Manual for more information about installing, removing, and upgrading NI software using Package Manager.

Notes

  • If Windows Update is enabled, the installation process might hang if Windows Update interferes with the installation of Microsoft Visual C++ 2015 Run-Time. Visit ni.com/r/exjq43 for more information and steps to resolve this issue.
  • Use the serial number that is included with your software to activate LabVIEW. For more information on LabVIEW activation, refer to Activating a Product.

Product Security and Critical Updates

Visit ni.com/security to view and subscribe to receive security notifications about NI products. For information about critical updates from NI, refer to Available Critical and Security Updates for NI Software.

Supported Hardware

Visit NI Hardware and Operating System Compatibility to view driver, desktop operating system, and real-time operating system support for individual hardware devices.

To view information for your device:

  • Select your hardware model in the dropdown list on the page to view compatibility information for your device.
  • Type your hardware model number in the dropdown list on the web page to filter the list of available devices.

Note: Some compatibility information may only be available in the archive attached to the NI Hardware and Operating System Compatibility page. For historic driver and OS support information, refer to the readme for the relevant driver version.

Finding Examples

Select Help»Find Examples from LabVIEW to launch the NI Example Finder. LabVIEW examples for LabVIEW are located in the \LabVIEW 2022\examples directory. You can modify an example VI to fit an application, or you can copy and paste from one or more examples into a VI that you create.

Automating the Installation of NI Products

You can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes.

If the NI product you are installing uses Microsoft .NET 4.6.2, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.6.2 separately before you install NI software.

For more information about automating the installation of NI products, refer to Automating an Installer in the NI Package Manager manual.

Using NI Software with Microsoft Windows 11

Microsoft Windows 11 is the latest version of the Windows operating system and features significant changes compared to previous versions. For more information about NI support for Windows 11, refer to NI Product Compatibility for Microsoft Windows 11.

Unsupported Windows Operating Systems

LabVIEW no longer supports Windows Vista/XP/7/8.x, Windows Server 2003/2008/2012, or any 32-bit Windows operating system. Versions of this product that ship after May 1, 2021, may not install or execute correctly on these operating systems. For detailed information about NI operating system support, visit https://www.ni.com/r/win32bitsupport.

NI No Longer Supports Phar Lap ETS Real-Time Operating System

NI Software no longer supports Phar Lap ETS Real-Time Operating System. Versions of this product that ship after May 1, 2022, may not install or execute correctly on this operating system. For high-level information on the support roadmap for Phar Lap and its replacement, NI Linux Real-Time, visit ni.com/r/xf35k1. To find out what hardware is supported on PXI controllers running NI Linux Real-Time, visit ni.com/r/b7g5wi.