November 2020
This file contains important information about PXI Platform Services, including installation instructions, new features, and a partial list of bugs fixed for PXI Platform Services 20.5.
If you plan to use LabVIEW NXG, refer to LabVIEW NXG Support and Considerations.
Product Security and Critical Updates
LabVIEW NXG Support and Considerations
Automating the Installation of NI Products
Using NI Software with Microsoft Windows 10
Using NI Software with Microsoft Windows 8.1
PXI Platform Services provides support for customers using NI PXI and PXI Express chassis and controllers.
If you are using PXI Platform Services 20.5 to upgrade a Windows system that serves as a host for one or more LabVIEW Real-Time Module targets, it is highly recommended that you also update your targets to leverage new features and improved performance.
Note You cannot use PXI Platform Services 20.5 to configure a LabVIEW RT target with a version of PXI Platform Services earlier than 2.0.
PXI Platform Services 20.5 supports the following operating systems:
1 NI software installs VC2015 Runtime and .NET 4.6.2. Windows 8.1 and Windows Server 2012 R2 require Microsoft updates to support these items. Refer to Microsoft KB2919442 and KB2919355 for more information about how to install these updates.
2 NI software is signed with a SHA-256 certificate. Windows 7 SP1, Windows Embedded Standard 7 SP1, and Windows Server 2008 R2 SP1 require Microsoft updates to support SHA-256. Refer to Microsoft KB3033929 and KB3125574 for more information about how to install these updates.
For the most up-to-date information on compatibility with PXI Platform Services, visit ni.com/info and enter the Info Code pxipsos.
Note Some hardware may not support all operating systems listed above. Consult your hardware documentation for more information.
Note Refer to PXI Platform Services Drops Support for Windows 7 (32- and 64-Bit), Windows Server 2008 R2, and All 32-Bit Windows Operating Systems in 2021 for information about future OS support.
Note Support for Windows 32-bit operating systems may require disabling physical address extension (PAE). To learn how this might affect your system and what actions you might need to take, visit ni.com/r/PAESupport.
PXI Platform Services 20.5 supports the following application software versions, including service packs.
Application Software | Versions Supported by PXI Platform Services |
---|---|
LabVIEW | 2017, 2018, 2019, 2020 |
LabVIEW NXG | 5.0 |
LabWindows™/CVI™ | 2013 and later |
NI installs PXI Platform Services using NI Package Manager. If you do not already have NI software installed, PXI Platform Services installs NI Package Manager to handle the installation of your NI software. Visit ni.com/r/NIPMDownload to download NI Package Manager. Refer to the NI Package Manager Manual for more information about installing, removing, and upgrading NI software using NI Package Manager.
Note If Windows Update is enabled, the installation process might hang if Windows Update interferes with the installation of Microsoft Visual C++ 2015 Run-Time. Visit ni.com/r/exjq43 for more information and steps to resolve this issue.
Visit ni.com/security to view and subscribe to receive security notifications about NI products. Visit ni.com/critical-updates for information about critical updates from NI.
Added support for new PXI hardware.
Added support for LabVIEW 2020 and LabVIEW NXG 5.0.
Added support for new PXI hardware.
PXI Platform Services has updated support for PXI Systems in NI Measurement & Automation Explorer (MAX) and the NI System Configuration API for LabVIEW, .NET, and C/C++. The following changes were made:
PXI Platform Services will no longer provide support for the following hardware:
PXI Platform Services supports PXI and PXI Express functionality. Visit ni.com/info and enter the Info Code pxipshw for a complete list of hardware that is compatible with PXI Platform Services.
The following sections detail considerations for using LabVIEW NXG 5.0 with PXI Platform Services 20.5.
Software support for LabVIEW NXG differs in the following ways:
View context help in LabVIEW by pressing <Ctrl-H> and hovering over an object.
Search for items using the search bar in the upper right corner of the LabVIEW window. You can also view context help for the search results.
Additional documentation is available online at ni.com/manuals.
Launch LabVIEW and click the Learning tab.
LabVIEW lessons are located in the Lessons tab, and LabVIEW Examples are located in the Examples tab. Follow the instructions in the lessons and examples.
You can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes.
If the NI product you are installing uses Microsoft .NET 4.6.2, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.6.2 separately before you install NI software.
For more information about automating the installation of NI products, refer to Automating an Installer in the NI Package Manager manual.
Microsoft Windows 10 is the latest version of the Windows operating system and features significant changes compared to previous versions. Windows 10 introduces several new capabilities and also combines features from both Windows 7 and Windows 8. For more information about NI support for Windows 10, visit ni.com/windows10.
When you install NI software on Microsoft Windows 8.1, you will notice a few additional tiles in the Apps view, including shortcuts to NI application software products such as NI LabVIEW, Measurement & Automation Explorer (NI MAX), and NI Launcher. For more information about NI support for Windows 8.1, visit ni.com/windows8.
PXI Platform Services will drop support for Windows 7 (32- and 64-bit), Windows Server 2008 R2, and all 32-bit Windows operating systems starting in 2021. Versions of this product that ship after May 1, 2021, may not install or execute correctly on these operating systems. For detailed information about NI operating system support, visit ni.com/r/win32bitsupport.
Copyright
© 1998–2020 National Instruments Corporation. All rights reserved.
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.
NI respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.
End-User License Agreements and Third-Party Legal Notices
You can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:
U.S. Government Restricted Rights
If you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.
IVI Foundation Copyright Notice
Content from the IVI specifications reproduced with permission from the IVI Foundation.
The IVI Foundation and its member companies make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The IVI Foundation and its member companies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Trademarks
Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.
Patents
For patents covering the NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the NI Patent Notice at ni.com/patents.
378480A-01