Overview

The LabVIEW DSC Module extends the LabVIEW graphical development environment with additional functionality for the rapid development of distributed measurement, control, and high-channel-count monitoring applications. The DSC Module enhances the LabVIEW shared variable, supports logging data to the Citadel and relational databases, enhances the Historical Data Viewer and the NI Distributed System Manager, and provides tools for graphing historical or real-time trends, enhancing the security of front panels, and writing custom I/O servers.

System Requirements

In addition to the system requirements for the LabVIEW Development System, the DSC Module has the following requirements:

  • LabVIEW 2020 Base, Full, or Professional Development System (32-bit)
  • At least 2.5 GB of disk space
  • 512 MB of RAM. NI recommends 1 GB of RAM.
  • Internet Explorer 6 Service Pack 1 or later

Refer to the LabVIEW Readme for additional system requirements and supported operating systems for LabVIEW.

Note  The DSC Module is compatible with LabVIEW (32-bit) only. Therefore, you must have LabVIEW (32-bit) installed even if you use a 64-bit OS.

Supported Operating Systems

The DSC Module supports the following operating systems:

  • Windows 10 (version 1909)/8.1 Update 11/7 SP12
  • Windows Server 2016
  • Windows Server 2012 R21
  • Windows Server 2008 R2 SP12

1 NI software installs VC2015 Runtime and .NET 4.6.2. Windows 8.1 and Windows Server 2012 R2 require Microsoft updates to support these items. Refer to Microsoft KB2919442 and KB2919355 for more information about how to install these updates.

2 NI software is signed with a SHA-256 certificate. Windows 7 SP1, Windows Embedded Standard 7 SP1, and Windows Server 2008 R2 SP1 require Microsoft updates to support SHA-256. Refer to Microsoft KB3033929 for more information about how to install this security update.

Note

  • In 2016 the LabVIEW DSC Module dropped support for Windows Vista, Windows XP, Windows Server 2003, and installations of Windows 7 without any service packs. The LabVIEW 2020 DSC Module will not install or run on an unsupported OS. You cannot deploy or distribute applications that use the LabVIEW 2020 DSC Module to an unsupported OS. Additionally, after installing the LabVIEW 2020 DSC Module, you cannot use any installers built on this computer with any version of LabVIEW, LabWindows™/CVI™, NI TestStand™, or Measurement Studio on an unsupported OS. For more information about the changes to our OS support for 2016, visit ni.com/r/OSSupport2016.
  • Support for Windows 32-bit operating systems may require disabling physical address extension (PAE). To learn how this might affect your system and what actions you might need to take, visit ni.com/r/PAESupport.
  • Refer to LabVIEW Datalogging and Supervisory Control Module Drops Support for Windows 7 (32- and 64-Bit), Windows Server 2008 R2, and All 32-Bit Windows Operating Systems in 2021 for information about future OS support.

Installation Instructions

NI installs the DSC Module using NI Package Manager. If you do not already have NI software installed, the DSC Module installs NI Package Manager to handle the installation of your NI software. Visit ni.com/r/NIPMDownload to download NI Package Manager. Refer to the NI Package Manager Manual for more information about installing, removing, and upgrading NI software using NI Package Manager.

You can also install LabVIEW and the DSC Module using the LabVIEW Platform media. To request additional LabVIEW Platform media, refer to the NI website.

Note  If you purchased this product with an NI Software Suite or NI Product Bundle, use the installation media that shipped with your purchase to install this product.

SQL Server Support

The LabVIEW 2020 DSC Module requires Microsoft SQL Server 2012 Service Pack 4 (SP4) Express. This component is installed by default when you install the DSC Module.

To install the LabVIEW 2020 DSC Module on a machine that has a previous version of the DSC Module installed, you need to upgrade the Microsoft SQL Server version from 2008 R2 to 2012 SP4 Express. Because upgrading the Microsoft SQL Server affects the Citadel database, you must backup your Citadel data before upgrading. Refer to the Archiving Citadel Data topic in the LabVIEW Help for detailed information about archiving the Citadel database.

Licensing

The DSC Module relies on licensing activation. When the evaluation period expires, you must activate a valid DSC Module license to continue using the DSC Module.

The NI OPC Servers application installed with the DSC Module provides a temporary license for a two-hour evaluation period. You must activate a valid license to continue using the NI OPC Servers application after the evaluation period expires.

Product Security and Critical Updates

Visit ni.com/security to view and subscribe to receive security notifications about NI products. Visit ni.com/critical-updates for information about critical updates from NI.

Known Issues

You can access the software and documentation known issues list online. Visit LabVIEW 2020 DSC Module Known Issues for an up-to-date list of known issues.

Accessing the Help

Refer to the LabVIEW Help, accessible by selecting Help»LabVIEW Help, for information about the DSC Module.

Finding Examples

Select Help»Find Examples from LabVIEW to launch the NI Example Finder. LabVIEW examples for the DSC Module are located in the labview\examples\lvdsc directory. You can modify an example VI to fit an application, or you can copy and paste from one or more examples into a VI that you create.

Automating the Installation of NI Products

You can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes.

If the NI product you are installing uses Microsoft .NET 4.6.2, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.6.2 separately before you install NI software.

For more information about automating the installation of NI products, refer to Automating an Installer in the NI Package Manager manual.

Using NI Software with Microsoft Windows 10

Microsoft Windows 10 is the latest version of the Windows operating system and features significant changes compared to previous versions. Windows 10 introduces several new capabilities and also combines features from both Windows 7 and Windows 8. For more information about NI support for Windows 10, visit ni.com/windows10.

Using NI Software with Microsoft Windows 8.1

When you install NI software on Microsoft Windows 8.1, you will notice a few additional tiles in the Apps view, including shortcuts to NI application software products such as NI LabVIEW, Measurement & Automation Explorer (NI MAX), and NI Launcher. For more information about NI support for Windows 8.1, visit ni.com/windows8.

LabVIEW Datalogging and Supervisory Control Module Drops Support for Windows 7 (32- and 64-Bit), Windows Server 2008 R2, and All 32-Bit Windows Operating Systems in 2021

The Datalogging and Supervisory Control Module will drop support for Windows 7 (32- and 64-bit), Windows Server 2008 R2, and all 32-bit Windows operating systems starting in 2021. Versions of this product that ship after May 1, 2021, may not install or execute correctly on these operating systems. For detailed information about NI operating system support, visit ni.com/r/win32bitsupport.


Legal Information

Copyright

© 2000–2020 National Instruments. All rights reserved.

Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.

NI respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.

End-User License Agreements and Third-Party Legal Notices

You can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:

  • Notices are located in the <National Instruments>\_Legal Information and <National Instruments> directories.
  • EULAs are located in the <National Instruments>\Shared\MDF\Legal\license directory.
  • Review <National Instruments>\_Legal Information.txt for information on including legal information in installers built with NI products.

U.S. Government Restricted Rights

If you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.

IVI Foundation Copyright Notice

Content from the IVI specifications reproduced with permission from the IVI Foundation.

The IVI Foundation and its member companies make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The IVI Foundation and its member companies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.

Trademarks

Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.

Patents

For patents covering the NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the NI Patent Notice at ni.com/patents.

375310G-01