June 2020
This file contains important information about the RFmx Demod, including system requirements, and installation instructions.
Product Security and Critical Updates
Automating the Installation of NI Products
Using NI Software with Microsoft Windows 10
Using NI Software with Microsoft Windows 8.1
RFmx Demod Drops Support for Windows 7 (64-Bit) and Windows Server 2008 R2 in 2021
RFmx Demod provides a highly optimized RF measurement experience. Use RFmx Demod to perform demodulation measurements on analog and digital modulation signal formats, including QAM and ASK.
RFmx Demod 20.0 includes the following new features:
RFmx Demod 19.1 includes the following new features:
RFmx Demod 19.0 includes the following new features:
The following hardware products are supported in all operating systems listed in the Supported Operating Systems section.
Device-specific information about these modules is included in the NI RF Vector Signal Analyzers Help.
Device-specific information about these modules is included in the NI RF Vector Signal Transceivers Help.
RFmx Demod has the following requirements:
* Depending on the amount of data acquired and/or processed, a larger amount of memory may be required.
RFmx Demod 20.0 supports the following 64-bit operating systems:
1 NI software installs VC2015 Runtime and .NET 4.6.2. Windows 8.1 and Windows Server 2012 R2 require Microsoft updates to support these items. Refer to Microsoft KB2919442 and KB2919355 for more information about how to install these updates.
2 NI software is signed with a SHA-256 certificate. Windows 7 SP1 and Windows Server 2008 R2 SP1 require Microsoft updates to support SHA-256. Refer to Microsoft KB3033929 and KB3125574 for more information about how to install these updates.
Note In 2019, RFmx Demod dropped support for all 32-bit Windows operating systems. RFmx Demod will not install or run on an unsupported OS. Refer to RFmx Demod Drops Support for Windows 7 (64-Bit) and Windows Server 2008 R2 in 2021 for information about future OS support.
Note In 2016, RFmx Demod dropped support for Windows Vista, Windows XP, Windows Server 2003, and installations of Windows 7 without any service packs. You cannot deploy or distribute applications that use RFmx Demod 20.0 to an unsupported OS. Additionally, after installing RFmx Demod 20.0, you cannot use any installers built on this computer with any version of LabVIEW, LabWindows™/CVI™, NI TestStand™, or Measurement Studio on an unsupported OS.
For more information about the changes to our OS support for 2016, visit ni.com/r/OSSupport2016.
RFmx Demod supports the following application software versions, including service packs. You should install application software, such as LabVIEW, LabWindows/CVI or Microsoft Visual Studio®, before installing RFmx Demod. To add support for application software installed after installing RFmx Demod modify your RFmx Demod installation or launch the RFmx Demod installer again. If you are not using NI application software, refer to Microsoft Visual Studio Support.
Application Software | Versions Supported by RFmx Demod |
---|---|
LabVIEW | 2017, 2018 SP1 f4 patch, 2019 SP1 f3 patch, 2020 |
LabWindows™/CVI™ | 2015 or later |
If you are using the RFmx Demod .NET Class Library, .NET Framework 4.0 (minimum) is required. The RFmx Demod .NET Class Library can be used with Visual C# or Visual Basic .NET in any Visual Studio version that can target .NET Framework 4.0.
NI installs RFmx Demod using NI Package Manager. If you do not already have NI software installed, RFmx Demod installs NI Package Manager to handle the installation of your NI software. Visit ni.com/info and enter the Info Code NIPMDownload to download NI Package Manager. Refer to the NI Package Manager Manual for more information about installing, removing, and upgrading NI software using NI Package Manager.
Notes
Item | Installed Location |
---|---|
Version Compatibility Checker | <NIDir>\RFmx\niRFmxCompatibility_Checker.exe |
Debug Configuration Utility | <NIDir>\RFmx\niRFmxDebugConfigurationUtility.exe |
DLLs | <SYSDIR> |
Header files |
<NIDir> \Shared\ExternalCompilerSupport\C\include |
Import Library files (64-bit) |
|
.NET Class Libraries | |
Assemblies |
<MSTUDIOVS2010DIR>\DotNET\Assemblies\Current\NationalInstruments.RFmx.DemodMx.Fx40.dll
<MSTUDIOVS2010DIR>\DotNET\Assemblies\Current\NationalInstruments.RFmx.InstrMX.Fx40.dll <MSTUDIOVS2010DIR>\DotNET\Assemblies\Current\NationalInstruments.Common.dll |
Select Start » All Programs » National Instruments» RFmx Demod»RFmx Demod Measurement Interactive Panel to launch the RFmx Demod Measurement Interactive Panel.
RFmx Demod palette VIs are available from the Functions » Measurement I/O » NI-RFmx » Demod palette.
Documentation for RFmx Demod is located at Start » All Programs » National Instruments » RFmx Demod » RFmx Demod Documentation. The documentation set is composed of the following documents.
Document | Format | Description |
---|---|---|
RFmx Demod Help | HTML/Windows Help |
Contains primary help content for RFmx Demod. This help file is an HTML version of a traditional user manual that includes the following information:
|
RFmx Demod 20.0 Readme | HTML (this document) | Contains information about supported hardware and operating systems, new features, fixed issues, and legal notices. |
You can access all the installed RFmx Demod examples at Start » All Programs » National Instruments » RFmx Demod » RFmx Demod Examples.
For the most recent revisions of documentation and for newly released documentation, visit ni.com/manuals.
Visit ni.com/security to view and subscribe to receive security notifications about National Instruments products. Visit ni.com/critical-updates for information about critical updates from National Instruments.
The following items are behavior changes in RFmx Demod 19.1 from RFmx Demod 19.0.
The following items are the behavior changes in RFmx Demod 19.0 from RFmx Demod 3.0.
You can access the RFmx Demod known issues list online at RFmx Demod 20.0 Known Issues.
You can access the RFmx Demod bug fix list online at RFmx Demod 20.0 Bug Fixes. This list describes a subset of issues fixed in the RFmx Demod. If you have a Bug ID, you can search this list to validate that the issue has been fixed.
You can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes.
If the NI product you are installing uses Microsoft .NET 4.6.2, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.6.2 separately before you install NI software.
For more information about automating the installation of NI products, refer to Automating an Installer in the NI Package Manager manual.
Microsoft Windows 10 is the latest version of the Windows operating system and features significant changes compared to previous versions. Windows 10 introduces several new capabilities and also combines features from both Windows 7 and Windows 8. For more information about NI support for Windows 10, visit ni.com/windows10.
When you install NI software on Microsoft Windows 8.1, you will notice a few additional tiles in the Apps view, including shortcuts to NI application software products such as NI LabVIEW, Measurement & Automation Explorer (NI MAX), and NI Launcher. For more information about NI support for Windows 8.1, visit ni.com/windows8.
RFmx Demod will drop support for Windows 7 (64-bit) and Windows Server 2008 R2 starting in 2021. Versions of this product that ship after May 1, 2021, may not install or execute correctly on these operating systems. For detailed information about NI operating system support, visit ni.com/r/win32bitsupport.
Copyright
© 2014–2020 National Instruments. All rights reserved.
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.
NI respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.
End-User License Agreements and Third-Party Legal Notices
You can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:
U.S. Government Restricted Rights
If you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.
IVI Foundation Copyright Notice
Content from the IVI specifications reproduced with permission from the IVI Foundation.
The IVI Foundation and its member companies make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The IVI Foundation and its member companies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Trademarks
Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.
Patents
For patents covering the NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the NI Patent Notice at ni.com/patents.
374855N-01