May 2017
This file contains important information about NI-DAQmx, including installation instructions and known issues.
Product Security and Critical Updates
Automating the Installation of NI Products
Using NI Software with Microsoft Windows 10
Using NI Software with Microsoft Windows 8.1
LabVIEW NXG Support and Considerations
NI-DAQmx is the software you use to communicate with and control your NI data acquisition (DAQ) device.
Refer to the NI website for any updates to the current NI-DAQmx readme.
System Use | RAM | Processor |
---|---|---|
Development/Deployment | 1 GB (32-bit), 2 GB (64-bit) | 1 GHz or faster 32-bit (x86) or 64-bit (x64) processor |
The following operating systems are supported by NI-DAQmx 17.1:
1 NI software installs VC2015 Runtime and .NET 4.6.2. Windows 8.1 and Windows Server 2012 R2 require Microsoft updates to support these items. Refer to Microsoft KB2919442 and KB2919355 for more information about how to install these updates.
2 NI software is signed with a SHA-256 certificate. Windows 7 SP1, Windows Embedded Standard 7 SP1, and Windows Server 2008 R2 SP1 require Microsoft updates to support SHA-256. Refer to Microsoft KB3033929 for more information about how to install this security update.
To find and download an earlier version of NI-DAQmx that supports other operating systems, refer to ni.com/downloads.
The following table lists the application software versions supported by NI-DAQmx. If you are not using application software, refer to Microsoft Visual Studio Support.
Application Software | Versions Supported by NI-DAQmx |
---|---|
LabVIEW | 2014, 2015, 2016, and 2017 |
LabVIEW Real-Time Module | 2014, 2015, 2016, and 2017 |
LabWindows™/CVI™ | 2012, 2013, 2015, and 2017 |
LabWindows/CVI Real-Time Module | 2015 and 2017 |
Measurement Studio | 2012, 2013, and 2015 |
SignalExpress | 2014 and 2015 |
The following table lists the programming languages and Microsoft Visual Studio versions supported by this version of NI-DAQmx. Earlier versions of NI-DAQmx support other application software and language versions.
Programming Language | Visual Studio Versions Supported by NI-DAQmx |
---|---|
ANSI C | 2003, 2005, 2008, 2010, and 2012 |
.NET Framework 4.0 Languages (Visual C# .NET and Visual Basic .NET) | 2010 |
.NET Framework 4.5 Languages (Visual C# .NET and Visual Basic .NET) | 2012 |
.NET Framework 4.5.1 Languages (Visual C# .NET and Visual Basic .NET) | 2013 |
For information on Visual Studio compatibility with earlier versions of NI-DAQmx, refer to ni.com/info and enter the info code NETlegacydrivers. To find and download an earlier version of a driver, refer to ni.com/downloads.
Support for 64-bit applications is available in NI-DAQmx 9.2.3 and later for Visual Studio 2010 support, NI-DAQmx 9.6.2 and later for Visual Studio 2012 support, and NI-DAQmx 14.5 and later for Visual Studio 2013.
For information on examples that use NI-DAQmx and Measurement Studio, refer to Where to Find Examples in the NI-DAQmx .NET Class Library Help.
Visit ni.com/security to view and subscribe to receive security notifications about NI products. Visit ni.com/critical-updates for information about critical updates from NI.
The following lists detail devices supported in NI-DAQmx and devices that are supported only on 32-bit versions of Windows 10/8.1/7:
The following lists detail the devices supported in NI-DAQmx. Device support is divided into the following categories:
Note In the device support tables that follow, a ✓ indicates that the device is supported, and a blank cell indicates that the device either does not exist or is not supported in NI-DAQmx.
The following X Series DAQ devices are supported:
Device | PCIe | PXIe | USB |
---|---|---|---|
NI 6320 | ✓ | ||
NI 6321 | ✓ | ||
NI 6323 | ✓ | ||
NI 6341 | ✓ | ✓ | ✓ |
NI 6343 | ✓ | ✓ | |
NI 6345 | ✓ | ||
NI 6351 | ✓ | ✓ | |
NI 6353 | ✓ | ✓ | |
NI 6355 | ✓ | ||
NI 6356 | ✓ | ✓ | |
NI 6358 | ✓ | ||
NI 6361 | ✓ | ✓ | ✓ |
NI 6363 | ✓ | ✓ | ✓ |
NI 6365 | ✓ | ||
NI 6366 | ✓ | ✓ | |
NI 6368 | ✓ | ||
NI 6375 | ✓ | ||
NI 6376 | ✓ | ||
NI 6378 | ✓ |
The following M Series DAQ devices are supported:
Device | PCI | PCIe | PXI | PXIe | USB |
---|---|---|---|---|---|
NI 6210/11/12/15/16/18 | ✓ | ||||
NI 6220 | ✓ | ✓ | |||
NI 6221 | ✓ | ✓ | ✓ | ||
NI 6224 | ✓ | ✓ | |||
NI 6225 | ✓ | ✓ | ✓ | ||
NI 6229 | ✓ | ✓ | ✓ | ||
NI 6230/32/33/36/38/39 | ✓ | ✓ | |||
NI 6250 | ✓ | ✓ | |||
NI 6251 | ✓ | ✓ | ✓ | ✓ | ✓ |
NI 6254 | ✓ | ✓ | |||
NI 6255 | ✓ | ✓ | ✓ | ||
NI 6259 | ✓ | ✓ | ✓ | ✓ | ✓ |
NI 6280 | ✓ | ✓ | |||
NI 6281 | ✓ | ✓ | ✓ | ||
NI 6284 | ✓ | ✓ | |||
NI 6289 | ✓ | ✓ | ✓ |
The following E Series DAQ devices are supported.
Device | PCMCIA | PCI | PXI |
---|---|---|---|
NI 6023E | ✓ | ||
NI 6024E* | ✓ | ✓ | |
NI 6025E | ✓ | ✓ | |
NI 6030E | ✓ | ||
NI 6031E | ✓ | ✓ | |
NI 6032E/33E/34E/35E | ✓ | ||
NI 6036E* | ✓ | ✓ | |
NI 6040E | ✓ | ||
NI 6052E | ✓ | ✓ | |
NI 6062E* | ✓ | ||
NI 6070E | ✓ | ||
NI 6071E | ✓ | ✓ | |
NI PCI-MIO-16E-1 | ✓ | ||
NI PCI-MIO-16E-4 | ✓ | ||
NI PCI-MIO-16XE-10 | ✓ | ||
NI PCI-MIO-16XE-50 | ✓ | ||
* Not supported on 64-bit versions of Windows 10/8.1/7 |
The following S Series DAQ devices are supported:
Device | PCI | PXI | PXIe |
---|---|---|---|
NI 6110 | ✓ | ||
NI 6111 | ✓ | ||
NI 6115 | ✓ | ✓ | |
NI 6120 | ✓ | ✓ | |
NI 6122 | ✓ | ✓ | |
NI 6123 | ✓ | ✓ | |
NI 6124 | ✓ | ||
NI 6132 | ✓ | ✓ | |
NI 6133 | ✓ | ✓ | |
NI 6143 | ✓ | ✓ | |
NI 6154 | ✓ |
The following SC Express devices are supported:
Device | PXIe |
---|---|
NI 4300 | ✓ |
NI 4302 | ✓ |
NI 4303 | ✓ |
NI 4304 | ✓ |
NI 4305 | ✓ |
NI 4309 | ✓ |
NI 4310 | ✓ |
NI 4322 | ✓ |
NI 4330 | ✓ |
NI 4331 | ✓ |
NI 4339 | ✓ |
NI 4340 | ✓ |
NI 4353 | ✓ |
NI 4357 | ✓ |
The following SC Express terminal blocks and other accessories are supported:
Device | Supported Accessory |
---|---|
NI 4300 | NI TB-4300, NI TB-4300B, NI TB-4300C, NI CAL-4300B |
NI 4302 | NI RM-4302, NI TB-4302, NI TB-4302C |
NI 4303 | NI RM-4302, NI TB-4302, NI TB-4302C |
NI 4304 | NI RM-4304, NI TB-4304 |
NI 4305 | NI RM-4304, NI TB-4304 |
NI 4309 | NI CAL-4309, NI TB-4309 (ST), NI TB-4309 (MT) |
NI 4310 | NI TB-4310 (10V), NI TB-4310 (600V) |
NI 4322 | NI TB-4322 |
NI 4330 | NI TB-4330 |
NI 4331 | NI TB-4330 |
NI 4339 | NI TB-4339, NI TB-4339B, NI TB-4339C, NI RM-4339 |
NI 4340 | NI TB-4340 |
NI 4353 | NI TB-4353, NI TC-4353, NI CAL-4353 |
NI 4357 | NI TB-4357 |
The following C Series, Network DAQ, and USB DAQ devices are supported:
Device | CompactDAQ Chassis* | Legacy Chassis and Carriers | ||
---|---|---|---|---|
NI ENET/WLS-9163 | NI USB-9162 | NI cDAQ-9172 | ||
NI 9201 | ✓ | ✓ | ✓ | |
NI 9203 | ✓ | ✓ | ||
NI 9205 | ✓ | ✓ | ✓ | |
NI 9206 | ✓ | ✓ | ✓ | |
NI 9207 | ✓ | ✓ | ||
NI 9208 | ✓ | ✓ | ||
NI 9209 | ✓ | |||
NI 9210 | ✓ | |||
NI 9211† | ✓ | ✓ | ✓ | ✓ |
NI 9212 | ✓ | |||
NI 9213 | ✓ | ✓ | ✓ | ✓ |
NI 9214 | ✓ | |||
NI 9215† | ✓ | ✓ | ✓ | ✓ |
NI 9216 | ✓ | |||
NI 9217 | ✓ | ✓ | ||
NI 9218 | ✓ | |||
NI 9219 | ✓ | ✓ | ✓ | ✓ |
NI 9220 | ✓ | |||
NI 9221 | ✓ | ✓ | ✓ | |
NI 9222 | ✓ | |||
NI 9223 | ✓ | |||
NI 9224 | ✓ | |||
NI 9225 | ✓ | ✓ | ||
NI 9226 | ✓ | |||
NI 9227 | ✓ | ✓ | ||
NI 9228 | ✓ | |||
NI 9229 | ✓ | ✓ | ✓ | |
NI 9230 | ✓ | |||
NI 9232 | ✓ | |||
NI 9233 | ✓ | ✓ | ✓ | |
NI 9234 | ✓ | ✓ | ✓ | ✓ |
NI 9235 | ✓ | ✓ | ||
NI 9236 | ✓ | ✓ | ||
NI 9237 | ✓ | ✓ | ✓ | ✓ |
NI 9237 (DSUB) | ✓ | ✓ | ||
NI 9238 | ✓ | |||
NI 9239 | ✓ | ✓ | ✓ | |
NI 9242 | ✓ | |||
NI 9244 | ✓ | |||
NI 9246 | ✓ | |||
NI 9247 | ✓ | |||
NI 9250 | ✓ | |||
NI 9251 | ✓ | |||
NI 9260 | ✓ | |||
NI 9263 | ✓ | ✓ | ✓ | |
NI 9264 | ✓ | ✓ | ✓ | |
NI 9265 | ✓ | ✓ | ✓ | |
NI 9269 | ✓ | ✓ | ||
NI 9344 | ✓ | |||
NI 9361 | ✓ | |||
NI 9375 | ✓ | |||
NI 9401 | ✓ | ✓ | ||
NI 9402 | ✓ | ✓ | ||
NI 9403 | ✓ | ✓ | ||
NI 9411 | ✓ | ✓ | ||
NI 9421 | ✓ | ✓ | ✓ | ✓ |
NI 9422 | ✓ | ✓ | ||
NI 9423 | ✓ | ✓ | ||
NI 9425 | ✓ | ✓ | ||
NI 9426 | ✓ | ✓ | ||
NI 9435 | ✓ | ✓ | ||
NI 9436 | ✓ | |||
NI 9437 | ✓ | |||
NI 9469 | ✓ | |||
NI 9472 | ✓ | ✓ | ✓ | ✓ |
NI 9474 | ✓ | ✓ | ||
NI 9475 | ✓ | ✓ | ||
NI 9476 | ✓ | ✓ | ||
NI 9477 | ✓ | ✓ | ||
NI 9478 | ✓ | ✓ | ||
NI 9481 | ✓ | ✓ | ✓ | ✓ |
NI 9482 | ✓ | |||
NI 9485 | ✓ | ✓ | ||
NI 9775 | ✓ | |||
* Does not include the NI cDAQ-9172. | ||||
† The NI USB-9211A and NI USB-9215A (C Series modules with a bundled NI USB-9162) are supported in NI-DAQmx. The NI USB-9211 and NI USB-9215 (C Series modules with a bundled NI USB-9161) are not supported in NI-DAQmx. |
The following CompactDAQ chassis are supported:
CompactDAQ Chassis | Ethernet | USB | Wireless |
---|---|---|---|
NI cDAQ-9171* | ✓ | ||
NI cDAQ-9172 | ✓ | ||
NI cDAQ-9174* | ✓ | ||
NI cDAQ-9178* | ✓ | ||
NI cDAQ-9179‡ | ✓ | ||
NI cDAQ-9181 | ✓ | ||
NI cDAQ-9184 | ✓ | ||
NI cDAQ-9185 | ✓ | ||
NI cDAQ-9188 | ✓ | ||
NI cDAQ-9189 | ✓ | ||
NI cDAQ-9188XT | ✓ | ||
NI cDAQ-9191 | ✓ | ✓ | |
* Support for this chassis was added in the LabVIEW Real-Time Module 2012. Refer to CompactDAQ Controllers for additional version compatibility. | |||
‡ This device does not support Phar Lap. |
The following CompactDAQ controllers are supported:
CompactDAQ Chassis | WES7 | Real Time |
---|---|---|
NI cDAQ-9132* | ✓ | ✓ |
NI cDAQ-9133* | ✓ | ✓ |
NI cDAQ-9134* | ✓ | ✓ |
NI cDAQ-9135* | ✓ | ✓ |
NI cDAQ-9136‡ | ✓ | ✓ |
NI cDAQ-9137‡ | ✓ | ✓ |
NI cDAQ-9138† | ✓ | ✓ |
NI cDAQ-9139† | ✓ | ✓ |
* Real-time support for this controller was added in the LabVIEW Real-Time Module 2014. | ||
‡ Real-time support for this controller was added in the LabVIEW Real-Time Module 2015. | ||
† Real-time support for this controller was added in the LabVIEW Real-Time Module 2012. |
The following AO Series devices are supported:
Device | DAQCard | PCI | PXI | PXIe |
---|---|---|---|---|
NI 6703 | ✓ | |||
NI 6704 | ✓ | ✓ | ||
NI 6711 | ✓ | ✓ | ||
NI 6713 | ✓ | ✓ | ||
NI 6715* | ✓ | |||
NI 6722 | ✓ | ✓ | ||
NI 6723 | ✓ | ✓ | ||
NI 6731 | ✓ | |||
NI 6733 | ✓ | ✓ | ||
NI 6738 | ✓ | |||
NI 6739 | ✓ | |||
* Not supported on 64-bit versions of Windows 10/8.1/7 |
The following digital I/O devices are supported.
Device | DAQCard | PCI | PCIe | PXI | PXIe | USB |
---|---|---|---|---|---|---|
NI 6501 | ✓ | |||||
NI 6503 | ✓ | |||||
NI 6508 | ✓ | |||||
NI 6509 | ✓ | ✓ | ✓ | ✓ | ||
NI 6510 | ✓ | |||||
NI 6511 | ✓ | ✓ | ||||
NI 6512 | ✓ | ✓ | ||||
NI 6513 | ✓ | ✓ | ||||
NI 6514 | ✓ | ✓ | ||||
NI 6515 | ✓ | ✓ | ||||
NI 6516 | ✓ | |||||
NI 6517 | ✓ | |||||
NI 6518 | ✓ | |||||
NI 6519 | ✓ | |||||
NI 6520 | ✓ | ✓ | ||||
NI 6521 | ✓ | ✓ | ||||
NI 6525 | ✓ | |||||
NI 6527 | ✓ | ✓ | ||||
NI 6528 | ✓ | ✓ | ||||
NI 6529 | ✓ | |||||
NI 6533 | ✓ | ✓ | ||||
NI 6534 | ✓ | ✓ | ||||
NI 6535 | ✓ | ✓ | ||||
NI 6535B | ✓ | |||||
NI 6536 | ✓ | ✓ | ||||
NI 6536B | ✓ | |||||
NI 6537 | ✓ | ✓ | ||||
NI 6537B | ✓ | |||||
NI DIO-24* | ✓ | |||||
NI DIO-32HS | ✓ | |||||
NI DIO-96 | ✓ | |||||
* Not supported on 64-bit versions of Windows 10/8.1/7 |
The following TIO series devices are supported:
Device | PCI | PCIe | PXI | PXIe |
---|---|---|---|---|
NI 6601 | ✓ | |||
NI 6602 | ✓ | ✓ | ||
NI 6608 | ✓ | |||
NI 6612 | ✓ | ✓ | ||
NI 6614 | ✓ | |||
NI 6624 | ✓ | ✓ |
The following DSA devices are supported:
Device | PCI | PXI | PXIe | USB |
---|---|---|---|---|
NI 4431 | ✓ | |||
NI 4432 | ✓ | |||
NI 4461 | ✓ | ✓ | ||
NI 4462 | ✓ | ✓ | ||
NI 4463 | ✓ | |||
NI 4464 | ✓ | |||
NI 4472/B | ✓ | ✓ | ||
NI 4474 | ✓ | |||
NI 4480 | ✓ | |||
NI 4481 | ✓ | |||
NI 4492 | ✓ | |||
NI 4495 | ✓ | |||
NI 4496 | ✓ | ✓ | ||
NI 4497 | ✓ | |||
NI 4498 | ✓ | ✓ | ||
NI 4499 | ✓ | |||
NI 4610 | ✓ |
The following SC Series DAQ devices are supported:
Device | PXI |
---|---|
NI 4200 | ✓ |
NI 4204 | ✓ |
NI 4220 | ✓ |
NI 4224 | ✓ |
Note As of NI-DAQmx 14.5, the NI-DAQmx Switch API is obsolete and is no longer recommended for new applications. For more information, refer to ni.com/info and enter the info code switchdriverconsiderations.
The following switches are supported:
Device | PCI | PXI | PXIe |
---|---|---|---|
NI 4021 | ✓ | ✓ | |
NI 2501 | ✓ | ||
NI 2503 | ✓ | ||
NI 2510 | ✓ | ||
NI 2512 | ✓ | ✓ | |
NI 2514 | ✓ | ✓ | |
NI 2515 | ✓ | ✓ | |
NI 2520 | ✓ | ||
NI 2521 | ✓ | ||
NI 2522 | ✓ | ||
NI 2523 | ✓ | ||
NI 2527 | ✓ | ✓ | |
NI 2529 | ✓ | ✓ | |
NI 2530 | ✓ | ||
NI 2531 | ✓ | ✓ | |
NI 2532 | ✓ | ✓ | |
NI 2533 | ✓ | ||
NI 2534 | ✓ | ||
NI 2535 | ✓ | ||
NI 2536 | ✓ | ||
NI 2540 | ✓ | ✓ | |
NI 2541 | ✓ | ✓ | |
NI 2542 | ✓ | ✓ | |
NI 2543 | ✓ | ✓ | |
NI 2544 | ✓ | ✓ | |
NI 2545 | ✓ | ||
NI 2546 | ✓ | ||
NI 2547 | ✓ | ||
NI 2548 | ✓ | ||
NI 2549 | ✓ | ||
NI 2554 | ✓ | ||
NI 2555 | ✓ | ||
NI 2556 | ✓ | ||
NI 2557 | ✓ | ||
NI 2558 | ✓ | ||
NI 2559 | ✓ | ||
NI 2564 | ✓ | ||
NI 2565 | ✓ | ||
NI 2566 | ✓ | ||
NI 2567 | ✓ | ||
NI 2568 | ✓ | ||
NI 2569 | ✓ | ✓ | |
NI 2570 | ✓ | ||
NI 2571 | ✓ | ||
NI 2575 | ✓ | ✓ | |
NI 2576 | ✓ | ||
NI 2584 | ✓ | ||
NI 2585 | ✓ | ||
NI 2586 | ✓ | ||
NI 2590 | ✓ | ||
NI 2591 | ✓ | ||
NI 2593 | ✓ | ✓ | |
NI 2594 | ✓ | ||
NI 2595 | ✓ | ||
NI 2596 | ✓ | ||
NI 2597 | ✓ | ||
NI 2598 | ✓ | ||
NI 2599 | ✓ | ||
NI 2720 | ✓ | ||
NI 2722 | ✓ | ||
NI 2725 | ✓ | ||
NI 2727 | ✓ | ||
NI 2800 | ✓ | ||
NI 2790 | ✓ | ||
NI 2796 | ✓ | ||
NI 2797 | ✓ | ||
NI 2798 | ✓ | ||
NI 2799 | ✓ | ||
NI 2810 | ✓ | ||
NI 2811 | ✓ | ||
NI 2812 | ✓ | ||
NI 2813 | ✓ | ||
NI 2814 | ✓ | ||
NI 2815 | ✓ | ||
NI 2816 | ✓ | ||
NI 2817 | ✓ | ||
NI 2833 | ✓ | ||
NI 2834 | ✓ | ||
NI 2865 | ✓ |
The following SCXI Chassis are supported:
The following SCXI modules are supported:
The following TEDS devices are supported:
The following academic devices are supported:
The following legacy DAQ devices (also called B Series devices) are supported:
Device | DAQ Pad | PCI | USB |
---|---|---|---|
NI DAQPad-6015* | ✓ | ||
NI DAQPad-6016* | ✓ | ||
NI PCI-6010 | ✓ | ||
NI PCI-6013 | ✓ | ||
NI PCI-6014 | ✓ | ||
SensorDAQ | ✓ | ||
* Not supported on 64-bit versions of Windows 10/8.1/7 |
The following low-cost USB devices (also called B Series devices) are supported:
Device | USB |
---|---|
NI 6000 | ✓ |
NI 6001 | ✓ |
NI 6002 | ✓ |
NI 6003 | ✓ |
NI 6008 | ✓ |
NI 6009 | ✓ |
NI TC01 | ✓ |
The following devices are supported in NI-DAQmx on the 32-bit versions of Windows 10/8.1/7. They are not supported on the 64-bit versions of Windows 10/8.1/7:
Refer to previous NI-DAQmx readmes, available on ni.com/drivers, for issues fixed in earlier versions of NI-DAQmx.
You can access the software and documentation known issues list online. Refer to the NI website for an up-to-date list of known issues in NI-DAQmx.
The following items are the IDs and titles of a subset of issues fixed in NI-DAQmx 17.1. This is not an exhaustive list of issues fixed. If you have a CAR ID, you can search this list to validate that the issue has been fixed.
CAR ID | Summary |
---|---|
448042 | Error -89137 when routing timebase in cDAQ chassis |
579138, 612354 | NI 9212 ADC Timing Mode cannot be changed in MAX/DAQ Assistant |
609577 | NI-DAQmx excitation voltage input threshold values are too close to absolute |
617309 | PXIe-4464 OpenCurrentLoop (open detection) and OverCurrent (short detection) is backwards |
628216 | C Series simulated devices return Error -50150 from DAQmx Set Temperature C Series Calibration VI |
634150 | Active output tasks with onboard-only regeneration enabled are not halted when Network cDAQ is explicitly unreserved |
You can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes. However, starting with the August 2012 releases (products using NI Installers version 3.1 or later), you may need to perform additional steps before or during a silent installation of NI software.
If the NI product you are installing uses Microsoft .NET 4.0, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.0 separately before you install NI software.
For more information about automating the installation of NI products, refer to the following KnowledgeBase articles:
Microsoft Windows 10 is the latest version of the Windows operating system and features significant changes compared to previous versions. Windows 10 introduces several new capabilities and also combines features from both Windows 7 and Windows 8. For more information about NI support for Windows 10, visit ni.com/windows10.
When you install NI software on Microsoft Windows 8.1, you will notice a few additional tiles in the Apps view, including shortcuts to NI application software products such as NI LabVIEW, Measurement & Automation Explorer (NI MAX), and NI Launcher. For more information about NI support for Windows 8.1, visit ni.com/windows8.
If you are using LabVIEW NXG 1.0, you can upgrade to NI-DAQmx 17.1 without breaking the compatibility of existing applications. However, newly supported features and devices in NI-DAQmx 17.1 will not be available.
Copyright
© 2003–2017 National Instruments. All rights reserved.
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.
NI respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.
End-User License Agreements and Third-Party Legal Notices
You can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:
U.S. Government Restricted Rights
If you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.
IVI Foundation Copyright Notice
Content from the IVI specifications reproduced with permission from the IVI Foundation.
The IVI Foundation and its member companies make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The IVI Foundation and its member companies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Trademarks
Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.
The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Patents
For patents covering the NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents.
374768P-01