April 2018
This file contains important information about NI-USRP, including installation instructions, new features, a partial list of bugs fixed for NI-USRP 17.2, and known issues.
Installed Software, Documentation, and Examples
Finding Examples and Sample Projects
Ethernet Support on USRP RIO Devices
Product Security and Critical Updates
Automating the Installation of NI Products
Using NI Software with Microsoft Windows 10
Using NI Software with Microsoft Windows 8.1
This software installation provides support for customers using software defined radio (USRP) devices and software defined radio reconfigurable (USRP RIO) devices, as specified in the Supported Hardware section. To program your USRP or USRP RIO device, use the NI-USRP API or USRP RIO Instrument Design Library (IDL) included in the NI-USRP instrument driver.
The getting started guide for your device provides information about how to install, configure, test, and begin using a USRP or USRP RIO device.
NI-USRP 17.2 adds support for the USRP-2974 device with LabVIEW Communications System Design Suite 2.0.
NI-USRP 17.1 adds support for several bug fixes.
NI-USRP 17.0 adds support for LabVIEW 2017 (32- and 64-bit).
NI-USRP 16.1 includes the following new features:
NI-USRP 16.0 adds support for LabVIEW 2016 (32- and 64-bit).
NI-USRP 15.5 includes the following new features:
NI-USRP 15.1 adds support for LabVIEW Communications 2.0.
NI-USRP 15.0 adds support for LabVIEW 2015 (32- and 64-bit).
The following hardware products are supported in all operating systems listed in the Supported Operating Systems section. Refer to the Application Software Support section for information regarding supported application software versions.
*The NI-USRP instrument driver supports TwinRX, UBX, CBX, CBX-120, WBX, WBX-120, SBX, SBX-120, XCVR2450
daughterboards. Other daughterboards may also be compatible, but they have not been tested.
Device-specific information about these modules is included in the NI-USRP Help.
NI-USRP 17.2 has the following requirements:
NI-USRP 17.2 supports the following operating systems:
Note NI-USRP 17.2 does not support Windows Server non-R2 editions.
NI recommends that you have the most recent service pack for your operating system installed.
Note In 2016, NI-USRP dropped support for Windows Vista, Windows XP, Windows Server 2003, and installations of Windows 7 without any service packs. NI-USRP 17.2 will not install or run on an unsupported OS. You cannot deploy or distribute applications that use NI-USRP 17.2 to an unsupported OS. Additionally, after installing NI-USRP 17.2, you cannot use any installers built on this computer with any version of LabVIEW, LabWindows™/CVI™, NI TestStand™, or Measurement Studio on an unsupported OS.
For more information about the changes to our OS support for 2016, refer to KB 79UC78LS, Why Does my LabVIEW, LabWindows/CVI, Measurement Studio, or TestStand Built Installer Fail on Windows XP/Vista and Server 2003?.
Note Support for Windows 32-bit operating systems may require disabling physical address extension (PAE). To learn how this might affect your system and what actions you might need to take, visit ni.com/info and enter the Info Code PAESupport.
1 NI software installs VC2015 Runtime and .NET 4.6.2. Windows 8.1 and Windows Server 2012 R2 require Microsoft updates to support these items. Refer to Microsoft KB2919442 and KB2919355 for more information about how to install these updates.
2 NI software is signed with a SHA-256 certificate. Windows 7 SP1, Windows Embedded Standard 7 SP1, and Windows Server 2008 R2 SP1 require Microsoft updates to support SHA-256. Refer to Microsoft KB3033929 for more information about how to install this security update.
NI-USRP 17.2 supports the following application software versions, including service packs. You should install application software, such as LabVIEW, LabVIEW Communications System Design Software, or LabVIEW Communications System Design Suite, before installing NI-USRP. To add support for application software installed after installing NI-USRP, modify your NI-USRP installation or launch the NI-USRP installer again.
Device | LabVIEW 2014 SP1, 2015 SP1, 2016, or 2017 | LabVIEW Communications System Design Software 2.0 | LabVIEW Communications System Design Suite 2.0 |
---|---|---|---|
USRP-2900/2901 | Yes | Yes | Yes |
USRP-2920/2921/2922 | Yes | Yes | Yes |
USRP-2930/2932 | Yes | Yes | Yes |
USRP-2940/2942/2943/2944 | Yes | No | Yes |
USRP-2950/2952/2953/2954 | Yes | No | Yes |
USRP-2945/2955 | Yes† | No | No |
USRP-2974 | No | No | Yes |
† The USRP-2945/2955 devices are supported only in LabVIEW 2016 and LabVIEW 2017.
Note NI-USRP is not supported in LabVIEW NXG 1.0 or later.
Item | Installed Location |
---|---|
NI-USRP | <NIDir32>\NI-USRP\ |
NI-USRP Utilities | <NIDir32>\NI-USRP\utilities\ |
NI-USRP Examples | <NIDir32>\LabVIEW<version>\examples\instr\niUSRP\ |
NI-USRP Header files | <NIDir32>\Shared\ExternalCompilerSupport\C\include |
NI-USRP Import Library files | <NIDir32>\Shared\ExternalCompilerSupport\C\lib32\msvc |
NI-USRP DLL | <SystemDir32>\niusrp.dll |
NI-USRP 2 DLL | <SystemDir32>\niusrp2.dll |
NI UHD DLL | <SystemDir32>\niuhd.dll |
NI UHD 2 DLL | <SystemDir32>\niuhd2.dll |
NI USRP RIO DLL | <SystemDir32>\niusrprio.dll |
NI USRP RIO RPC | <SystemDir32>\niusrpriorpc.exe |
NI USRP USB Monitor | <SystemDir32>\niusrpmonitor.exe |
NI-USRP Firmware and FPGA images | <NIDir32>\NI-USRP\images\ |
Item | Installed Location |
---|---|
NI-USRP | <NIDir64>\NI-USRP\ |
NI-USRP Header files | <NIDir32>\Shared\ExternalCompilerSupport\C\include |
NI-USRP Import Library files | <NIDir32>\Shared\ExternalCompilerSupport\C\lib64\msvc |
NI-USRP DLL | <SystemDir64>\niusrp.dll |
NI-USRP 2 DLL | <SystemDir64>\niusrp2.dll |
NI UHD DLL | <SystemDir64>\niuhd.dll |
NI UHD 2 DLL | <SystemDir64>\niuhd2.dll |
NI USRP RIO DLL | <SystemDir64>\niusrprio.dll |
NI-USRP Examples | <NIDir64>\LabVIEW<version>\examples\instr.lib\niUSRP\ |
Documentation for NI-USRP is located at Start»All Programs»National Instruments»NI-USRP»Documentation. The documentation set is composed of the following documents.
Document | Format | Description |
---|---|---|
NI-USRP Help | HTML/Windows Help | The primary document for most NI USRP products. The help is an HTML version of a traditional user manual that includes the following information:
|
Getting Started Guide for your device | Printed and PDF | Contains software and hardware installation, configuration, signal connection, and troubleshooting information for your device. |
Specifications for your device | Lists technical specifications for your device. | |
NI-USRP 17.2 Readme | HTML (this document) | Contains information about supported hardware and operating systems, new features, fixed issues, and legal notices. |
To access the LabVIEW Communications System Design Suite 2.0 Manual, visit ni.com/info and enter the Info Code commsmanual. This manual includes the following information:
For the most recent revisions of documentation and for newly released documentation, visit ni.com/manuals.
Note To view PDFs, you need to have Adobe Acrobat Reader installed. You can install the viewer from www.adobe.com/reader.
NI–USRP palette VIs are available from the Functions»Instrument I/O»Instrument Drivers»NI-USRP palette.
USRP RIO palette VIs are available from the Functions»Instrument I/O»Instrument Drivers»USRP RIO palette.
NI-USRP includes several example applications for LabVIEW. These examples serve as interactive tools, programming models, and as building blocks in your own applications. NI-USRP includes examples for getting started and other software-defined radio (SDR) functionality. You can access the NI-USRP examples from the following locations:
Note The NI Example Finder does not include NI-USRP examples.
USRP RIO includes several sample projects for LabVIEW. These sample projects serve as starting points to build a USRP RIO streaming application. To access the LabVIEW sample project from the Create Project dialog, select Sample Projects in the left pane and navigate to the NI-USRP Simple Streaming project.
You can access additional examples from the Code Sharing Community at ni.com/usrp.
USRP RIO devices support both 1G Ethernet and 10G Ethernet using the connectors on the device back panel. With the default FPGA image, port 0 is designated for 1G, and port 1 is designated for 10G.
The USRP-2974 is only supported through Ethernet using 1 GbE through RJ45 and 10 GbE through SFP+ connections.
Note The FPGA cannot be modified when the USRP RIO device is connected through Ethernet.
Visit ni.com/security to view and subscribe to receive security notifications about NI products. Visit ni.com/critical-updates for information about critical updates from NI.
You can access the software and documentation known issues list online. Refer to the NI website for an up-to-date list of known issues in NI-USRP 17.2.
There are no changes in NI-USRP 17.2 from NI-USRP 17.1.
The following items are changes in NI-USRP 17.1 from NI-USRP 17.0.
ID | Fixed Issue |
---|---|
679121 | Fixed an issue that caused digital data values in the NI-USRP Simple Streaming with USRP-2945/2955 Sample Project to be scaled to half of the correct value. |
681935 | Fixed an issue that caused aliases to appear in the data path after the frequency shift occurred on the FPGA. |
The following items are changes in NI-USRP 17.0 from NI-USRP 16.1.
ID | Fixed Issue |
---|---|
641880 | Fixed an issue that caused the RF frequency to be inaccurate due to LO sharing when using the USRP-2945/2955 and the USRP RIO sample project. |
624459 | Fixed an issue that caused the building of a bitfile to fail using DRAM in LabVIEW Communications 2.0 after installing NI-USRP. |
617872 | Fixed an issue that caused the streaming performance of USRP RIO devices to degrade when connected over PCIe and using NI-USRP API. |
The following items are changes in NI-USRP 16.1 from NI-USRP 16.0.
ID | Fixed Issue |
---|---|
597196 | Fixed an issue that caused errors to appear when launching the NI-USRP Configuration Utility from LabVIEW Communications 2.0. |
494050 | Fixed an issue that caused the USRP-2950/2952/2953/2954 devices not to set the GPS time by default. |
There are no changes in NI-USRP 16.0 from NI-USRP 15.5.
The following items are changes in NI-USRP 15.5 from NI-USRP 15.1.
ID | Fixed Issue |
---|---|
544731 | Fixed an issue that caused Rx/Tx samples to be misaligned by 5 ns when synchronizing using the external PPS on a USRP RIO device. |
519793 | Fixed an issue that caused two channel acquisitions (Rx) on a single USRP-2901 device to fail to align. |
486961 | Fixed an issue that caused the niUSRP Find Devices VI to occasionally return incorrect information when a session is open to a USRP device. |
466351 | Fixed an issue that caused "A stream command was issued in the past" or "Packet had timestamp that was late (or too early)" errors to occur with MIMO synchronization. |
There are no changes in NI-USRP 15.1 from NI-USRP 15.0.
The following items are changes in NI-USRP 15.0 from NI-USRP 14.5.1.
ID | Fixed Issue |
---|---|
544473 | Fixed an issue that caused the niUSRP Configure Frequency Shift VI to incorrectly negate the Tx shift when the scope was "all". |
You can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes.
If the NI product you are installing uses Microsoft .NET 4.0, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.0 separately before you install NI software.
For more information about automating the installation of NI products, refer to the following KnowledgeBase articles:
Microsoft Windows 10 is the latest version of the Windows operating system and features significant changes compared to previous versions. Windows 10 introduces several new capabilities and also combines features from both Windows 7 and Windows 8. For more information about NI support for Windows 10, visit ni.com/windows10.
When you install NI software on Microsoft Windows 8.1, you will notice a few additional tiles in the Apps view, including shortcuts to NI application software products such as NI LabVIEW, Measurement & Automation Explorer (NI MAX), and NI Launcher. For more information about NI support for Windows 8.1, visit ni.com/windows8.
Copyright
© 2011–2018 National Instruments. All rights reserved.
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.
NI respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.
End-User License Agreements and Third-Party Legal Notices
You can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:
U.S. Government Restricted Rights
If you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.
IVI Foundation Copyright Notice
Content from the IVI specifications reproduced with permission from the IVI Foundation.
The IVI Foundation and its member companies make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The IVI Foundation and its member companies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Trademarks
Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.
Patents
For patents covering the NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the NI Patent Notice at ni.com/patents.
374760M-01