The Meltdown and Spectre vulnerabilities are unspecific to any one vendor and take advantage of techniques commonly used in most modern processor architectures. This means a large range of products are affected. Mitigations could include updates to both OSs and firmware (BIOS).
NI recommends customers follow security best practices to protect against exploitation of vulnerabilities. These practices include adopting software updates, avoiding unrecognized hyperlinks and websites, not downloading files or applications from unknown sources, and following secure password policies.
NI has observed some negative system performance impact from applying the mitigations. Generally, performance degradation is in line with reports from the industry. In some cases, the impact could be significant but is specific to the application. Due to the system performance impact, these mitigations may be disabled by default.
NI Linux Real-Time distributions based on LabVIEW Real-Time 2019 and later (linux kernel 4.14+RT or later and firmware version 7.0 or later) ship with several security mitigations addressing the following CVEs:
Depending on the NI Linux Real-Time controller, you may need to perform one or more of the following steps.
For more information on upgrading the firmware and enabling the mitigations in the OS, please refer to Enabling Security Mitigations for Meltdown and Spectre on NI Linux Real-Time Controllers.
NI Linux Real-Time (Intel x64) Controller List
A BIOS update and a Firmware update is necessary to address Meltdown, Spectre Variant 1, 2 & 4, and Foreshadow (as of 6/1/2019).
Controllers | BIOS Update |
PXIe-8840 QC | 2.1.3f0 |
PXIe-8861 | Ships with BIOS mitigations |
PXIe-8880 | 2.1.2f0 |
cDAQ-9132 | 1.3.1.f0 |
cDAQ-9133 | 1.3.1.f0 |
cDAQ-9134 | 1.3.1.f0 |
cDAQ-9135 | 1.3.1.f0 |
cDAQ-9136 | 1.3.1.f0 |
cDAQ-9137 | 1.3.1.f0 |
cRIO-9030 | 1.3.3f0 |
cRIO-9031 | 1.3.3f0 |
cRIO-9032 | 1.3.3f0 WiFi |
cRIO-9033 | 1.3.3f0 |
cRIO-9034 | 1.3.3f0 |
cRIO-9035 | 1.3.3f0 |
cRIO-9035 (Sync) | 1.3.3f0 |
cRIO-9036 | 1.3.3f0 |
cRIO-9037 | 1.3.3f0 WiFi |
cRIO-9038 | 1.3.3f0 |
cRIO-9039 | 1.3.3f0 |
cRIO-9039 (Sync) | 1.3.3f0 |
cRIO-9040 | 1.2.1f0 |
cRIO-9042 | 1.2.1f0 |
cRIO-9043 | 1.2.1f0 |
cRIO-9045 | 1.2.1f0 |
cRIO-9047 | 1.2.1f0 |
cRIO-9048 | 1.2.1f0 |
cRIO-9048 TPM | 1.2.1f0 TPM |
cRIO-9049 | 1.2.1f0 |
IC-3120 | 1.3.1f0 |
IC-3121 | 1.3.1f0 |
NI CVS-1458RT | 1.3.0f0 |
NI CVS-1459RT | 1.3.0f0 |
IC 3171 | 1.1.2f0 |
IC 3172 | 1.1.2f0 |
IC-3173 | 1.1.2f0 |
ISC-1780 | 1.10.035* |
ISC-1781 | 1.10.035* |
ISC-1782 | 1.10.035* |
ISC-1783 | 1.10.035* |
*To upgrade your ISC hardware to BIOS version 1.10.05 contact NI Technical Support at ni.com/support.
CompactDAQ/CompactRIO/Vision/OEM Controller (NI Linux Real-Time ARM) List
A Firmware update to 7.0 for ARM-based controllers is necessary to address Spectre Variant 1 & 2 before enabling mitigations (As of 6/1/2019).
Controllers |
cRIO-9063 |
cRIO-9064 |
cRIO-9065 |
cRIO-9066 |
cRIO-9067 |
cRIO-9068 |
sbRIO-9607 |
sbRIO-9627 |
sbRIO-9637 |
sbRIO-9651 |
myRIO-1900 |
myRIO-1950 |
NI-7931 |
NI-7932 |
NI-7935 |
NI roboRIO |
NI ELVIS RIO Control Module |
For more information on the update process, refer to Upgrading Firmware on my NI Linux Real-Time Devices and Enabling Security Mitigations for Meltdown and Spectre on NI Linux Real-Time Controllers.