LabVIEW 2016 SoftMotion Module Patch Details

The LabVIEW SoftMotion Module 2016 f2 Patch is available for the LabVIEW 2016 SoftMotion Module. NI recommends this patch for all LabVIEW 2016 SoftMotion Module installations.

This patch will also be available via Update Service. If you already have LabVIEW 2016 SoftMotion Module installed, Update Service will update your computer with the LabVIEW SoftMotion Module 2016 f2 Patch. If you have not yet installed LabVIEW 2016 SoftMotion Module, Update Service will update your computer with LabVIEW SoftMotion Module 2016 f2, which is a full installer that includes both LabVIEW 2016 SoftMotion Module and the f2 patch.

The LabVIEW SoftMotion Module 2016 f2 Patch is cumulative and includes the changes found in the f1 patch. The patch fixes the issues listed in the tables below.

Issues Fixed in the LabVIEW SoftMotion Module 2016 f2 Patch

IDDescription
583192SDI Axes do not implement the Smoothing attribute on reference moves
591142SDI Axes do not have Home Switch Enabled by default or available in Axis Configuration dialog
607840SoftMotion Drive Interface (SDI) VIs will not deploy when SoftMotion is not licensed
613626Position Capture on SDI and UDV Axes do not handle position rollover
615087SDI Axes can fault when changing move modes
632971SDI Axes do not work after SoftMotion is re-initialized
643434SDI Axis position cannot be reset following a home move
667021SoftMotion Set Plugin Mode will not properly close the SDI plug-in if an error is input
618627LabVIEW RT crash when running SoftMotion Axes at high Scan Engine rates
639822LabVIEW RT crash when continuously calling property nodes on different resources in parallel


Issues Fixed in the LabVIEW SoftMotion Module 2016 f1 Patch

IDDescription
602055Wait Until Done VI completes execution before move is complete
600105Position move setpoint can jump out of range on move start
601616VxWorks RT Controllers do not work with SoftMotion Remote Axes
595072Position Error resets without being commanded
602758SoftMotion Help contains incorrect description when an axis in a coordinate is stopped
601614Opening FPGA VI with SoftMotion FPGA IP always has a dependency conflict