VeriStand 2025 Q1 Bug Fixes

Overview

The following items are notable issues fixed between the release of VeriStand 2024 Q4 and VeriStand 2025 Q1, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of VeriStand.

Bug Number

Legacy ID

Description

Details

2685173

VeriStand project saved with missing Custom Devices throws deployment errors

Saving a VeriStand project that includes a custom device with missing files in the install folder, causes errors during deployment.

Workaround:

Manually edit the System Definition xml file and update RT Driver VI path with Custom Device file location OR Delete and re-add the Custom Devices before saving System Explorer

Reported Version:

VeriStand 2023 Q4

Resolved Version:

VeriStand 2025 Q1

Added:

N/A

2817575

Modifying ADAS Toolkit configurations causes VeriStand crash

Switching to VeriStand screen immediately after modifying ADAS Toolkit configuration causes VeriStand to crash.

Workaround:

There is currently no known workaround for this issue.

Reported Version:

VeriStand 2023 Q4

Resolved Version:

VeriStand 2025 Q1

Added:

N/A

2944310

ASAM XIL Read/Write APIs throws error for multi-dimensional data type

Calling the ASAM XIL Read and Write APIs with multi-dimensional data values results in a type cast error.

Workaround:

In VeriStand, enable Segment into scalars option for model array ports and perform ASAM XIL Read/Write API calls on individual array element.

Reported Version:

VeriStand 2020 R6

Resolved Version:

VeriStand 2025 Q1

Added:

N/A

2954846

CAN Port Settings are not displayed correctly when switching between CAN ports

When switching between different CAN ports, the CAN Port Settings tab shows the General tab information instead of the specific settings for the selected port.

Workaround:

Toggle to different tab to get the values displayed correctly.

Reported Version:

VeriStand 2024 Q3

Resolved Version:

VeriStand 2025 Q1

Added:

N/A

Additional Patch Information

Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.

These patches currently do not have any special instructions.

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID â€“ An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).