This document contains the ETX Inverter Production Test System Software Suite known issues that were discovered before and since the release of ETX Inverter Production Test System Software Suite 2024 Q1. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
2688850 |
Dry Contact Error undescriptive when using NI-Pulser and RM-16061A user can get a dry contact error when using NI-Pulser Driver and RM-16061 pulser hardware in certain situations unrelated to the RM-16061 interlock dry contact state. Workaround: The interlock must be closed in order for the NI-Pulser Driver to allow a pulse to occur. If the interlock is closed and this error still occurs, the most likely cause is an issue with state change in other hardware in the pulser composite instrument.
|
Reported Version: ETX Inverter Production Test System Software Suite: 2024 Q1 Resolved Version: N/A Added: Jan 7, 2025 |
|
2903019 |
NI-Pulser Session errors or hangs if session left idle and openWorkaround: Kill the following processes: 1. NationalInstruments.ECUTS.PulseCurrentMuxService.exe 2. NationalInstruments.ECUTS.PulserService.exe. Then re-run your program |
Reported Version: ETX Inverter Production Test System Software Suite: 2024 Q1 Resolved Version: N/A Added: Jan 7, 2025 |
|
2976293 |
RM-26999 Serial Number (SN) reported within Maintenance Software is different than SN logged within NI databaseThe RM-26999’s within the ETX-1620x systems report back a SN within Maintenance Software (MSW) that does not match the SN genealogy tied to the NI hardware SN database. Workaround: You must find the SN of each RM-26999 on the sticker located just below each DAQ Device connector on the device.
|
Reported Version: ETX Inverter Production Test System Software Suite: 2024 Q1 Resolved Version: N/A Added: Jan 7, 2025 |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.