The following items are notable issues fixed between the release of SystemLink 2023 Q4 and SystemLink 2024 Q1, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of SystemLink.

Bug Number

Legacy ID

Description

Details

2580885

SystemLink report plugin for TestStand - Error on 'Disable Result Recording for All Sequences' in Station Options

When "Disable Result Recording for All Sequences" is enabled, an error occasionally would occur while finalizing the result with error code -2147467261. This would occurs because we try to get the status from a null step.

Workaround:

This issue is fixed in the SystemLink Client 2020 R4.5 Patch and SystemLink Client 2024 Q1

Reported Version:

SystemLink Client 2023 Q4

Resolved Version:

SystemLink Client 2020 R4.5 Patch | SystemLink Client 2024 Q1

Added:

Jan 16, 2024

2677018

TDM Data Navigator - Export, Add to Data Cart, Downloads are all disabled and grayed out

Installing SystemLink Server TDM 2023 Q3 Patch 3 results in the TDM Data Navigator UI having the Export and Add to Data Cart options, as well as the Downloads button disabled and grayed out.

Workaround:

There is currently no known workaround for this issue.

Reported Version:

SystemLink 2023 Q3

Resolved Version:

SystemLink 2023 Q3 Patch 4

Added:

Apr 30, 2024

2805992

SystemLink Test Monitor service fails to start after upgrading the server

Upgrading Systemlink Server 23Q3 Patch 2 (or greater) to 24Q1 Patch 2 (or lesser) causes the Test Monitor service to fail to start. The service fails to load and reports an error with no details. To confirm if you are impacted by this issue, inspect the "C:\Program Files\National Instruments\Shared\Skyline\TestMonitor" directory and confirm that "NationalInstruments.TestMonitor.dll" is not present.

Workaround:

This issue can be resolved by repairing the Test Monitor installation. Back up any configuration files before executing the repair.

Reported Version:

SystemLink 2024 Q1

Resolved Version:

SystemLink 2024 Q1 Patch 3

Added:

Oct 14, 2024

Additional Patch Information

Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.

These patches currently do not have any special instructions.

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).